Skip to main content
WireAndSun
Calculators
CEC PV Module

PEIMAR SM365M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SM365M is a 365.0 W STC (338.2 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 18.81% efficiency, 48.68 V Voc at 25 C, and 53.3 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
365.0 W
PTC Wattage
338.2 W
Voc @ 25C
48.68 V
Efficiency
18.81%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SM365M Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for PEIMAR SM365M (Mono-c-Si) residential solar systems. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

PEIMAR SM365M delivers 188.1 W/m2 (1.10 percentage points below 19.91% CEC median) and strong 92.7% PTC-to-STC heat retention (#11,468 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (459 sq ft). At -4 F (-20 C), string voltage climbs to 54.62 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with Caterpillar Inc PVC365MP03 (365.0 W).

Where Does PEIMAR SM365M Fall Across Listed CEC Models?

Comparison of PEIMAR SM365M (365.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SM365M (365.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SM365M: 365.0 W

What Dataset Percentiles Define PEIMAR SM365M?

Relative ranking of PEIMAR SM365M across nameplate watts, 92.7% PTC thermal ratio, and module aperture efficiency. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

PEIMAR SM365M Engineering BenchmarksPercentile comparison of PEIMAR SM365M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage365.0 WPTC/STC Retention92.7%Module Efficiency18.81%

What Do the Dataset Ranks Show for PEIMAR SM365M?

Summary of PEIMAR SM365M output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.

Rank #12,044 / 21,677

365.0 W STC · Higher Than 42.9%

365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,807

18.81% Aperture Efficiency

Power density 188.1 W/m2 (1.10 percentage points below 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.3 V at -10 C (586.3 V string) and 54.62 V at -20 C (10 max).

8 kW Reference Array

22 Panels = 8,030 W STC

Occupies 42.7 m2 (459 sq ft) producing 7,440 W PTC; NEC 690.8 OCPD floor is 15.13 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.68 * (1 + (-0.271/100) * (-10 - 25)) = 53.3 V | OCPD = 1.56 * 9.7 = 15.13 A

Inputs from CEC Modules.csv for PEIMAR SM365M: Voc=48.68 V, beta_Voc=-0.271%/C, Isc=9.7 A, STC=365.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (586.3 V); 22 panels for 8 kW (459 sq ft).

What Are the Published CEC Specifications for PEIMAR SM365M?

Complete CEC test sheet for PEIMAR SM365M including Isc (9.7 A), Voc (48.68 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SM365M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 365.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 338.2 W (92.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.68 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.7 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.9 V / 9.16 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.271 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.81% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SM365M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using PEIMAR SM365M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.21 kW 355 sq ft $1,554 $2,628
8 kW Class 22 8.03 kW 459 sq ft $2,010 $3,398
10 kW Class 28 10.22 kW 585 sq ft $2,558 $4,325

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

Related PEIMAR power steps and black/silver trims consolidated into this PEIMAR SM365M series guide. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the PEIMAR SM365M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SM355M 355.0 W 328.7 W 48.19 V 39.5 V 18.3%
PEIMAR SM360M 360.0 W 333.4 W 48.44 V 39.7 V 18.56%
PEIMAR SM365M 365.0 W 338.2 W 48.68 V 39.9 V 18.81%
PEIMAR SM370M 370.0 W 342.9 W 48.92 V 40.1 V 19.07%

How Many PEIMAR SM365M Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for PEIMAR SM365M (48.68 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=48.68V and beta_Voc=-0.271%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.62 V 10 panels 546.2 V 18 panels
-10 C (14 F) 53.3 V 11 panels 586.3 V 18 panels
0 C (32 F) 51.98 V 11 panels 571.8 V 19 panels
25 C (77 F STC) 48.68 V 12 panels 584.2 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SM365M?

Four comparable CEC modules such as Caterpillar Inc PVC365MP03 (365.0 W) for side-by-side solar quote checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Caterpillar Inc PVC365MP03
Caterpillar Inc
365.0 W Tie (0 W) 48.13 V 19.41% 93.4%
CertainTeed CT365M10-03
CertainTeed
365.0 W Tie (0 W) 47.8 V 18.98% 91.6%
CertainTeed CT365M10-02
CertainTeed
365.0 W Tie (0 W) 47.66 V 19.39% 91.9%
CertainTeed CT365M11-02
CertainTeed
365.0 W Tie (0 W) 47.66 V 19.39% 91.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SM365M?

Evaluate PEIMAR SM365M (365.0 W STC, 48.68 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SM365M reaches 54.62 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 459 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (459 sq ft).
  • 2026 tax credit baseline: cash residential installs of PEIMAR SM365M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SM365M 8 kW Residential Fit

Needs 22 modules (459 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Caterpillar Inc PVC365MP03.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 338.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SM365M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

How many PEIMAR SM365M panels fit on a 600 V winter solar string?

At -10 C (14 F), PEIMAR SM365M cold Voc rises from 48.68 V to 53.3 V (beta_Voc -0.271%/C), capping a 600 V string at 11 panels (586.3 V).

How much roof area does an 8 kW array of PEIMAR SM365M need?

An 8 kW DC system uses 22 PEIMAR SM365M modules (8,030 W STC / 7,440 W PTC), covering roughly 459 sq ft and saving ~$2,010/yr at 18.54 c/kWh.

How does PEIMAR SM365M compare against Caterpillar Inc PVC365MP03?

PEIMAR SM365M outputs 365.0 W STC (48.68 V Voc, rank #12,044 of 21,677), while Caterpillar Inc PVC365MP03 delivers 365.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.