PEIMAR SM325M (FB) is a 325.0 W STC (300.0 W PTC) Mono-c-Si solar module ranking #14,546 of 21,677 CEC listings (below all-CEC median; higher than 31.1% of peers). It delivers 19.94% efficiency, 41.67 V Voc at 25 C, and 45.8 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 325.0 W
- PTC Wattage
- 300.0 W
- Voc @ 25C
- 41.67 V
- Efficiency
- 19.94%
How Does PEIMAR SM325M (FB) Compare Against Peer CEC Listings?
Solar engineering breakdown for PEIMAR SM325M (FB): PTC thermal retention, roof footprint, and cold Voc string bounds. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
Across 5,889 Mono-c-Si listings from PEIMAR and peers, PEIMAR SM325M (FB) stands 85.0 W below the 410.0 W Mono-c-Si median and strong 92.3% PTC-to-STC heat retention (#13,268 of 21,677). Sizing 6 kW (19 panels) to 10 kW (31 panels) yields $1,544-$2,520/yr in baseline US bill offset. Mid-range 41.67 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does PEIMAR SM325M (FB) Fall Across Listed CEC Models?
Distribution marker showing PEIMAR SM325M (FB) (325.0 W) relative to the 385.0 W all-CEC solar panel median. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
What Dataset Percentiles Define PEIMAR SM325M (FB)?
Dataset percentiles tracking PEIMAR SM325M (FB) power output, thermal retention ratio, and aperture efficiency against 21,677 models. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Do the Dataset Ranks Show for PEIMAR SM325M (FB)?
Benchmark highlights for PEIMAR SM325M (FB) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
325.0 W STC · Higher Than 31.1%
325.0 W STC (-60.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.94% Aperture Efficiency
Power density 199.4 W/m2 (0.03 percentage points above 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.8 V at -10 C (595.4 V string) and 46.98 V at -20 C (12 max).
25 Panels = 8,125 W STC
Occupies 40.8 m2 (439 sq ft) producing 7,500 W PTC; NEC 690.8 OCPD floor is 15.72 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.67 * (1 + (-0.283/100) * (-10 - 25)) = 45.8 V | OCPD = 1.56 * 10.08 = 15.72 A
Inputs from CEC Modules.csv for PEIMAR SM325M (FB): Voc=41.67 V, beta_Voc=-0.283%/C, Isc=10.08 A, STC=325.0 W, Area=1.63 m2.
Result: 13 panels max on 600 V (595.4 V); 25 panels for 8 kW (439 sq ft).
What Are the Published CEC Specifications for PEIMAR SM325M (FB)?
Official CEC datasheet figures for PEIMAR SM325M (FB) (Mono-c-Si) used in utility interconnection and permit reviews. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 325.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 300.0 W (92.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.67 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.08 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.15 V / 9.52 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.283 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.94% (1.63 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many PEIMAR SM325M (FB) Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many PEIMAR SM325M (FB) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.17 kW | 333 sq ft | $1,544 | $2,611 |
| 8 kW Class | 25 | 8.12 kW | 439 sq ft | $2,032 | $3,437 |
| 10 kW Class | 31 | 10.07 kW | 544 sq ft | $2,520 | $4,262 |
How Many PEIMAR SM325M (FB) Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on PEIMAR SM325M (FB) (45.8 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.98 V | 12 panels | 563.8 V | 21 panels |
| -10 C (14 F) | 45.8 V | 13 panels | 595.4 V | 21 panels |
| 0 C (32 F) | 44.62 V | 13 panels | 580.1 V | 22 panels |
| 25 C (77 F STC) | 41.67 V | 14 panels | 583.4 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to PEIMAR SM325M (FB)?
Competing CEC solar panels closest to PEIMAR SM325M (FB) in nameplate wattage and Voc, starting with Auxin Solar AXN6M610T325.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6M610T325 Auxin Solar |
325.0 W | Tie (0 W) | 42.2 V | 19.98% | 91.9% |
| Boviet Solar Technology Co Ltd BVM6610M-330L-H Boviet Solar Technology Co Ltd |
330.0 W | +5.0 W | 41.9 V | 19.76% | 93.6% |
| Boviet Solar Technology Co Ltd BVM6610M-330-H Boviet Solar Technology Co Ltd |
330.0 W | +5.0 W | 41.95 V | 20.25% | 93.2% |
| Boviet Solar Technology Co Ltd BVM6610M-W5-330-H Boviet Solar Technology Co Ltd |
330.0 W | +5.0 W | 41.95 V | 20.28% | 93.2% |
What Are the Design Limits and Best-Fit Uses for PEIMAR SM325M (FB)?
Evaluate PEIMAR SM325M (FB) (325.0 W STC, 41.67 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SM325M (FB) reaches 46.98 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 439 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (439 sq ft).
- 2026 tax credit baseline: cash residential installs of PEIMAR SM325M (FB) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PEIMAR SM325M (FB) 8 kW Residential Fit
Needs 25 modules (439 sq ft) with a 20 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Auxin Solar AXN6M610T325.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 300.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PEIMAR SM325M (FB) by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for PEIMAR SM325M (FB)?
Multiplying PEIMAR SM325M (FB)'s 10.08 A short-circuit current by 1.56 equals 15.72 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can PEIMAR SM325M (FB) pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 45.8 V cold Voc at 14 F and handles 10.08 A Isc; string inverters cap PEIMAR SM325M (FB) at 13 panels on 600 V.
Is PEIMAR SM325M (FB) eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PEIMAR SM325M (FB) rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)