Skip to main content
WireAndSun
Calculators
CEC PV Module

PEIMAR SL455M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SL455M is a 455.0 W STC (426.9 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 21.06% efficiency, 50.36 V Voc at 25 C, and 55.08 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
455.0 W
PTC Wattage
426.9 W
Voc @ 25C
50.36 V
Efficiency
21.06%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SL455M Compare Against Peer CEC Listings?

How PEIMAR PEIMAR SL455M handles rooftop heat (426.9 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, PEIMAR SL455M exhibits 11.45 A short-circuit current, requiring a 17.86 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #5,417 of 21,677 (45.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 38.9 m2 for an 8 kW system (22 panels for 10 kW). Higher 50.36 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does PEIMAR SL455M Fall Across Listed CEC Models?

Where PEIMAR SL455M (455.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SL455M (455.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SL455M: 455.0 W

What Dataset Percentiles Define PEIMAR SL455M?

Percentile placement of PEIMAR SL455M across power density (210.6 W/m2), thermal retention, and nameplate STC wattage. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

PEIMAR SL455M Engineering BenchmarksPercentile comparison of PEIMAR SL455M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage455.0 WPTC/STC Retention93.8%Module Efficiency21.06%

What Do the Dataset Ranks Show for PEIMAR SL455M?

Four critical engineering numbers homeowners and solar installers check first when reviewing PEIMAR SL455M specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #5,417 / 21,677

Top 26.2% STC Output

455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,104

21.06% Aperture Efficiency

Power density 210.6 W/m2 (1.15 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.08 V at -10 C (550.8 V string) and 56.43 V at -20 C (10 max).

8 kW Reference Array

18 Panels = 8,190 W STC

Occupies 38.9 m2 (419 sq ft) producing 7,684 W PTC; NEC 690.8 OCPD floor is 17.86 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.36 * (1 + (-0.268/100) * (-10 - 25)) = 55.08 V | OCPD = 1.56 * 11.45 = 17.86 A

Inputs from CEC Modules.csv for PEIMAR SL455M: Voc=50.36 V, beta_Voc=-0.268%/C, Isc=11.45 A, STC=455.0 W, Area=2.16 m2.

Result: 10 panels max on 600 V (550.8 V); 18 panels for 8 kW (419 sq ft).

What Are the Published CEC Specifications for PEIMAR SL455M?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PEIMAR SL455M. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SL455M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 455.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 426.9 W (93.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 50.36 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.45 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.1 V / 10.81 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.268 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.06% (2.16 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SL455M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PEIMAR SL455M (455.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.37 kW 326 sq ft $1,594 $2,696
8 kW Class 18 8.19 kW 419 sq ft $2,050 $3,466
10 kW Class 22 10.01 kW 512 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

All closely matched PEIMAR wattages and cosmetic trims sharing the PEIMAR SL455M architecture. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the PEIMAR SL455M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SL450M 450.0 W 422.1 W 50.1 V 41.9 V 20.83%
PEIMAR SL455M 455.0 W 426.9 W 50.36 V 42.1 V 21.06%
PEIMAR SL460M 460.0 W 431.7 W 50.64 V 42.3 V 21.3%

How Many PEIMAR SL455M Modules Fit in a Cold-Weather String?

Maximum series module counts for PEIMAR SL455M from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=50.36V and beta_Voc=-0.268%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.43 V 10 panels 564.3 V 17 panels
-10 C (14 F) 55.08 V 10 panels 550.8 V 18 panels
0 C (32 F) 53.73 V 11 panels 591.0 V 18 panels
25 C (77 F STC) 50.36 V 11 panels 554.0 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SL455M?

Alternative CEC solar modules from competing brands near PEIMAR SL455M (455.0 W), including HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S455XI.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S455XI
HD HYUNDAI ENERGY SOLUTIONS CO LTD
455.0 W Tie (0 W) 50.0 V 20.97% 93.9%
HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S455YI
HD HYUNDAI ENERGY SOLUTIONS CO LTD
455.0 W Tie (0 W) 50.0 V 20.97% 93.8%
Apollo Renewables Inc Apollo-M672BH-455TW
Apollo Renewables Inc
455.0 W Tie (0 W) 49.8 V 21.16% 93.5%
Bluesun Solar CoLtd BSM455M-72HPH
Bluesun Solar CoLtd
455.0 W Tie (0 W) 49.8 V 20.97% 92.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SL455M?

Evaluate PEIMAR SL455M (455.0 W STC, 50.36 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SL455M reaches 56.43 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 419 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (419 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PEIMAR SL455M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SL455M 8 kW Residential Fit

Needs 18 modules (419 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S455XI.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 426.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SL455M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Why is PEIMAR SL455M PTC wattage (426.9 W) lower than STC (455.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 426.9 W PTC (93.8% retention) across PEIMAR SL455M's 2.16 m2 aperture.

Who should skip PEIMAR SL455M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 PEIMAR SL455M panels (419 sq ft) leave unusable roof gaps vs. HD HYUNDAI ENERGY SOLUTIONS CO LTD HiS-S455XI.

What is the 1,000 V commercial string limit for PEIMAR SL455M?

On 1,000 V commercial inverters at -10 C (55.08 V cold Voc), PEIMAR SL455M fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting PEIMAR SL455M.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.