PEIMAR SL380M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SL380M is a 380.0 W STC (356.5 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 20.99% efficiency, 42.11 V Voc at 25 C, and 46.06 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
380.0 W
PTC Wattage
356.5 W
Voc @ 25C
42.11 V
Efficiency
20.99%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SL380M Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for PEIMAR SL380M (Mono-c-Si) residential solar systems. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Homeowners evaluating PEIMAR SL380M need 16 panels for 6 kW or 22 panels (429 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (429 sq ft). Under NEC 690.7(A), beta_Voc (-0.268%/C) pushes open-circuit voltage to 46.06 V at 14 F and 47.19 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does PEIMAR SL380M Fall Across Listed CEC Models?

Comparison of PEIMAR SL380M (380.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SL380M (380.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SL380M: 380.0 W

What Dataset Percentiles Define PEIMAR SL380M?

Relative ranking of PEIMAR SL380M across nameplate watts, 93.8% PTC thermal ratio, and module aperture efficiency. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

PEIMAR SL380M Engineering BenchmarksPercentile comparison of PEIMAR SL380M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage380.0 WPTC/STC Retention93.8%Module Efficiency20.99%

What Do the Dataset Ranks Show for PEIMAR SL380M?

Summary of PEIMAR SL380M output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.

Rank #11,043 / 21,677

380.0 W STC · Higher Than 47.6%

380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,482

20.99% Aperture Efficiency

Power density 209.9 W/m2 (1.08 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 46.06 V at -10 C (598.8 V string) and 47.19 V at -20 C (12 max).

8 kW Reference Array

22 Panels = 8,360 W STC

Occupies 39.8 m2 (429 sq ft) producing 7,843 W PTC; NEC 690.8 OCPD floor is 17.89 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 42.11 * (1 + (-0.268/100) * (-10 - 25)) = 46.06 V | OCPD = 1.56 * 11.47 = 17.89 A

Inputs from CEC Modules.csv for PEIMAR SL380M: Voc=42.11 V, beta_Voc=-0.268%/C, Isc=11.47 A, STC=380.0 W, Area=1.81 m2.

Result: 13 panels max on 600 V (598.8 V); 22 panels for 8 kW (429 sq ft).

What Are the Published CEC Specifications for PEIMAR SL380M?

Complete CEC test sheet for PEIMAR SL380M including Isc (11.47 A), Voc (42.11 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SL380M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 380.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 356.5 W (93.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 42.11 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.47 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.1 V / 10.83 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.268 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.99% (1.81 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SL380M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using PEIMAR SL380M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.08 kW 312 sq ft $1,522 $2,573
8 kW Class 22 8.36 kW 429 sq ft $2,092 $3,538
10 kW Class 27 10.26 kW 526 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

Related PEIMAR power steps and black/silver trims consolidated into this PEIMAR SL380M series guide. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the PEIMAR SL380M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SL375M 375.0 W 351.7 W 41.8 V 34.9 V 20.72%
PEIMAR SL380M 380.0 W 356.5 W 42.11 V 35.1 V 20.99%
PEIMAR SL385M 385.0 W 361.3 W 42.26 V 35.3 V 21.27%

How Many PEIMAR SL380M Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for PEIMAR SL380M (42.11 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=42.11V and beta_Voc=-0.268%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 47.19 V 12 panels 566.3 V 21 panels
-10 C (14 F) 46.06 V 13 panels 598.8 V 21 panels
0 C (32 F) 44.93 V 13 panels 584.1 V 22 panels
25 C (77 F STC) 42.11 V 14 panels 589.5 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SL380M?

Four comparable CEC modules such as DualSun SAS DualSun 380M-120-01 (380.0 W) for side-by-side solar quote checks. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DualSun SAS DualSun 380M-120-01
DualSun SAS
380.0 W Tie (0 W) 41.3 V 21.47% 93.9%
Boviet Solar Technology Co Ltd BVM6610M-380S-H-HC
Boviet Solar Technology Co Ltd
380.0 W Tie (0 W) 40.94 V 20.54% 94.2%
CSI Solar Co Ltd CS3L-385MS
CSI Solar Co Ltd
385.0 W +5.0 W 41.4 V 21.51% 93.2%
CSI Solar Co Ltd CS3L-375P
CSI Solar Co Ltd
375.0 W -5.0 W 41.2 V 20.95% 92.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SL380M?

Evaluate PEIMAR SL380M (380.0 W STC, 42.11 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SL380M reaches 47.19 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 429 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (429 sq ft).
  • 2026 tax credit baseline: cash residential installs of PEIMAR SL380M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SL380M 8 kW Residential Fit

Needs 22 modules (429 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare DualSun SAS DualSun 380M-120-01.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 356.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SL380M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Why is PEIMAR SL380M PTC wattage (356.5 W) lower than STC (380.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 356.5 W PTC (93.8% retention) across PEIMAR SL380M's 1.81 m2 aperture.

Who should skip PEIMAR SL380M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 PEIMAR SL380M panels (429 sq ft) leave unusable roof gaps vs. DualSun SAS DualSun 380M-120-01.

What is the 1,000 V commercial string limit for PEIMAR SL380M?

On 1,000 V commercial inverters at -10 C (46.06 V cold Voc), PEIMAR SL380M fits up to 21 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting PEIMAR SL380M.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.