Skip to main content
WireAndSun
Calculators
CEC PV Module

PEIMAR SG360M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SG360M is a 360.0 W STC (328.1 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 18.56% efficiency, 48.44 V Voc at 25 C, and 54.2 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
360.0 W
PTC Wattage
328.1 W
Voc @ 25C
48.44 V
Efficiency
18.56%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SG360M Compare Against Peer CEC Listings?

Solar engineering breakdown for PEIMAR SG360M: PTC thermal retention, roof footprint, and cold Voc string bounds. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Measured at 360.0 W STC and 328.1 W PTC, PEIMAR SG360M sits -25.0 W vs all-CEC median (below all-CEC median; higher than 41.3% of peers) among 21,677 listed modules. Power density reaches 185.6 W/m2 (1.35 percentage points below 19.91% CEC median). Higher 48.44 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer DEHUI SOLAR POWER INC DH-72M-360W rates 360.0 W.

Where Does PEIMAR SG360M Fall Across Listed CEC Models?

Distribution marker showing PEIMAR SG360M (360.0 W) relative to the 385.0 W all-CEC solar panel median. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SG360M (360.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SG360M: 360.0 W

What Dataset Percentiles Define PEIMAR SG360M?

Dataset percentiles tracking PEIMAR SG360M power output, thermal retention ratio, and aperture efficiency against 21,677 models. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

PEIMAR SG360M Engineering BenchmarksPercentile comparison of PEIMAR SG360M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage360.0 WPTC/STC Retention91.1%Module Efficiency18.56%

What Do the Dataset Ranks Show for PEIMAR SG360M?

Benchmark highlights for PEIMAR SG360M covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Rank #12,385 / 21,677

360.0 W STC · Higher Than 41.3%

360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,241

18.56% Aperture Efficiency

Power density 185.6 W/m2 (1.35 percentage points below 19.91% CEC median). PTC/STC ratio: 91.1% (rank #16,462).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.2 V at -10 C (596.2 V string) and 55.85 V at -20 C (10 max).

8 kW Reference Array

23 Panels = 8,280 W STC

Occupies 44.6 m2 (480 sq ft) producing 7,546 W PTC; NEC 690.8 OCPD floor is 15.15 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.44 * (1 + (-0.34/100) * (-10 - 25)) = 54.2 V | OCPD = 1.56 * 9.71 = 15.15 A

Inputs from CEC Modules.csv for PEIMAR SG360M: Voc=48.44 V, beta_Voc=-0.34%/C, Isc=9.71 A, STC=360.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (596.2 V); 23 panels for 8 kW (480 sq ft).

What Are the Published CEC Specifications for PEIMAR SG360M?

Official CEC datasheet figures for PEIMAR SG360M (Mono-c-Si) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SG360M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 360.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 328.1 W (91.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.44 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.71 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.7 V / 9.07 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.34 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.56% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SG360M Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many PEIMAR SG360M modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.12 kW 355 sq ft $1,532 $2,590
8 kW Class 23 8.28 kW 480 sq ft $2,072 $3,504
10 kW Class 28 10.08 kW 585 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

Consolidated PEIMAR wattage variants sharing the PEIMAR SG360M mechanical and cell layout. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sibling CEC listings grouped into the PEIMAR SG360M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SG350M 350.0 W 318.7 W 47.21 V 38.7 V 18.04%
PEIMAR SG355M 355.0 W 323.4 W 47.34 V 38.8 V 18.3%
PEIMAR SG360M 360.0 W 328.1 W 48.44 V 39.7 V 18.56%
PEIMAR SG365M 365.0 W 332.8 W 48.68 V 39.9 V 18.81%
PEIMAR SG370M 370.0 W 337.5 W 48.93 V 40.1 V 19.07%

How Many PEIMAR SG360M Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on PEIMAR SG360M (54.2 V at 14 F). Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Computed from Voc=48.44V and beta_Voc=-0.34%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.85 V 10 panels 558.5 V 17 panels
-10 C (14 F) 54.2 V 11 panels 596.2 V 18 panels
0 C (32 F) 52.56 V 11 panels 578.2 V 19 panels
25 C (77 F STC) 48.44 V 12 panels 581.3 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SG360M?

Competing CEC solar panels closest to PEIMAR SG360M in nameplate wattage and Voc, starting with DEHUI SOLAR POWER INC DH-72M-360W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DEHUI SOLAR POWER INC DH-72M-360W
DEHUI SOLAR POWER INC
360.0 W Tie (0 W) 49.1 V 18.72% 91.4%
Advance Power API-M360
Advance Power
360.0 W Tie (0 W) 47.56 V 18.56% 91.7%
Auxin Solar AXN6M612T360
Auxin Solar
360.0 W Tie (0 W) 47.56 V 18.55% 91.7%
Boviet Solar Technology Co Ltd BVM6612M-360
Boviet Solar Technology Co Ltd
360.0 W Tie (0 W) 47.5 V 18.56% 92.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SG360M?

Evaluate PEIMAR SG360M (360.0 W STC, 48.44 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SG360M reaches 55.85 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 23 panels for an 8 kW build require 480 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (480 sq ft).
  • 2026 tax credit baseline: cash residential installs of PEIMAR SG360M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SG360M 8 kW Residential Fit

Needs 23 modules (480 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare DEHUI SOLAR POWER INC DH-72M-360W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 328.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SG360M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

How many PEIMAR SG360M panels fit on a 600 V winter solar string?

At -10 C (14 F), PEIMAR SG360M cold Voc rises from 48.44 V to 54.2 V (beta_Voc -0.34%/C), capping a 600 V string at 11 panels (596.2 V).

How much roof area does an 8 kW array of PEIMAR SG360M need?

An 8 kW DC system uses 23 PEIMAR SG360M modules (8,280 W STC / 7,546 W PTC), covering roughly 480 sq ft and saving ~$2,072/yr at 18.54 c/kWh.

How does PEIMAR SG360M compare against DEHUI SOLAR POWER INC DH-72M-360W?

PEIMAR SG360M outputs 360.0 W STC (48.44 V Voc, rank #12,385 of 21,677), while DEHUI SOLAR POWER INC DH-72M-360W delivers 360.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.