Skip to main content
WireAndSun
Calculators
CEC PV Module

PEIMAR SG335M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SG335M is a 335.0 W STC (304.6 W PTC) Mono-c-Si solar module ranking #13,844 of 21,677 CEC listings (below all-CEC median; higher than 34.7% of peers). It delivers 17.26% efficiency, 46.85 V Voc at 25 C, and 52.43 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
335.0 W
PTC Wattage
304.6 W
Voc @ 25C
46.85 V
Efficiency
17.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SG335M Compare Against Peer CEC Listings?

How PEIMAR PEIMAR SG335M handles rooftop heat (304.6 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, PEIMAR SG335M exhibits 9.34 A short-circuit current, requiring a 14.57 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #13,844 of 21,677 (75.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 46.6 m2 for an 8 kW system (30 panels for 10 kW). Mid-range 46.85 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does PEIMAR SG335M Fall Across Listed CEC Models?

Where PEIMAR SG335M (335.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SG335M (335.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SG335M: 335.0 W

What Dataset Percentiles Define PEIMAR SG335M?

Percentile placement of PEIMAR SG335M across power density (172.7 W/m2), thermal retention, and nameplate STC wattage. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

PEIMAR SG335M Engineering BenchmarksPercentile comparison of PEIMAR SG335M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage335.0 WPTC/STC Retention90.9%Module Efficiency17.26%

What Do the Dataset Ranks Show for PEIMAR SG335M?

Four critical engineering numbers homeowners and solar installers check first when reviewing PEIMAR SG335M specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #13,844 / 21,677

335.0 W STC · Higher Than 34.7%

335.0 W STC (-50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #16,118

17.26% Aperture Efficiency

Power density 172.7 W/m2 (2.65 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.43 V at -10 C (576.7 V string) and 54.02 V at -20 C (11 max).

8 kW Reference Array

24 Panels = 8,040 W STC

Occupies 46.6 m2 (501 sq ft) producing 7,310 W PTC; NEC 690.8 OCPD floor is 14.57 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.85 * (1 + (-0.34/100) * (-10 - 25)) = 52.43 V | OCPD = 1.56 * 9.34 = 14.57 A

Inputs from CEC Modules.csv for PEIMAR SG335M: Voc=46.85 V, beta_Voc=-0.34%/C, Isc=9.34 A, STC=335.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (576.7 V); 24 panels for 8 kW (501 sq ft).

What Are the Published CEC Specifications for PEIMAR SG335M?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PEIMAR SG335M. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SG335M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 335.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 304.6 W (90.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.85 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.34 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.4 V / 8.72 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.34 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.26% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SG335M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PEIMAR SG335M (335.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.03 kW 376 sq ft $1,509 $2,552
8 kW Class 24 8.04 kW 501 sq ft $2,012 $3,403
10 kW Class 30 10.05 kW 626 sq ft $2,515 $4,253

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

All closely matched PEIMAR wattages and cosmetic trims sharing the PEIMAR SG335M architecture. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the PEIMAR SG335M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SG325M 325.0 W 292.9 W 45.14 V 36.7 V 16.75%
PEIMAR SG330M 330.0 W 297.5 W 45.26 V 36.8 V 17.01%
PEIMAR SG335M 335.0 W 304.6 W 46.85 V 38.4 V 17.26%
PEIMAR SG340M 340.0 W 309.3 W 46.97 V 38.5 V 17.52%
PEIMAR SG345M 345.0 W 314.0 W 47.09 V 38.6 V 17.78%

How Many PEIMAR SG335M Modules Fit in a Cold-Weather String?

Maximum series module counts for PEIMAR SG335M from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=46.85V and beta_Voc=-0.34%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.02 V 11 panels 594.2 V 18 panels
-10 C (14 F) 52.43 V 11 panels 576.7 V 19 panels
0 C (32 F) 50.83 V 11 panels 559.1 V 19 panels
25 C (77 F STC) 46.85 V 12 panels 562.2 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SG335M?

Alternative CEC solar modules from competing brands near PEIMAR SG335M (335.0 W), including Bluesun Solar Energy Tech CoLtd BSM335P-72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Bluesun Solar Energy Tech CoLtd BSM335P-72
Bluesun Solar Energy Tech CoLtd
335.0 W Tie (0 W) 46.76 V 17.29% 91.4%
Centrosolar America EM72 335BW
Centrosolar America
335.0 W Tie (0 W) 46.75 V 17.42% 91.4%
Centrosolar America EM72 335SW
Centrosolar America
335.0 W Tie (0 W) 46.75 V 17.42% 91.4%
Auxin Solar AXN6M612T335
Auxin Solar
335.0 W Tie (0 W) 47.04 V 17.26% 91.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SG335M?

Evaluate PEIMAR SG335M (335.0 W STC, 46.85 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SG335M reaches 54.02 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 501 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (501 sq ft).
  • 2026 tax credit baseline: cash residential installs of PEIMAR SG335M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SG335M 8 kW Residential Fit

Needs 24 modules (501 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM335P-72.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 304.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SG335M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Why is PEIMAR SG335M PTC wattage (304.6 W) lower than STC (335.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 304.6 W PTC (90.9% retention) across PEIMAR SG335M's 1.94 m2 aperture.

Who should skip PEIMAR SG335M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 24 PEIMAR SG335M panels (501 sq ft) leave unusable roof gaps vs. Bluesun Solar Energy Tech CoLtd BSM335P-72.

What is the 1,000 V commercial string limit for PEIMAR SG335M?

On 1,000 V commercial inverters at -10 C (52.43 V cold Voc), PEIMAR SG335M fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting PEIMAR SG335M.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.