PEIMAR SG260P is a 260.0 W STC (235.7 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 15.95% efficiency, 37.81 V Voc at 25 C, and 42.18 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 260.0 W
- PTC Wattage
- 235.7 W
- Voc @ 25C
- 37.81 V
- Efficiency
- 15.95%
How Does PEIMAR SG260P Compare Against Peer CEC Listings?
How PEIMAR PEIMAR SG260P handles rooftop heat (235.7 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, PEIMAR SG260P exhibits 8.98 A short-circuit current, requiring a 14.01 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #19,146 of 21,677 (18.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 50.5 m2 for an 8 kW system (39 panels for 10 kW). Lower 37.81 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does PEIMAR SG260P Fall Across Listed CEC Models?
Where PEIMAR SG260P (260.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define PEIMAR SG260P?
Percentile placement of PEIMAR SG260P across power density (159.5 W/m2), thermal retention, and nameplate STC wattage. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
What Do the Dataset Ranks Show for PEIMAR SG260P?
Four critical engineering numbers homeowners and solar installers check first when reviewing PEIMAR SG260P specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
260.0 W STC · Higher Than 10.4%
260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.95% Aperture Efficiency
Power density 159.5 W/m2 (3.96 percentage points below 19.91% CEC median). PTC/STC ratio: 90.7% (rank #17,330).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.18 V at -10 C (590.5 V string) and 43.42 V at -20 C (13 max).
31 Panels = 8,060 W STC
Occupies 50.5 m2 (544 sq ft) producing 7,307 W PTC; NEC 690.8 OCPD floor is 14.01 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.81 * (1 + (-0.33/100) * (-10 - 25)) = 42.18 V | OCPD = 1.56 * 8.98 = 14.01 A
Inputs from CEC Modules.csv for PEIMAR SG260P: Voc=37.81 V, beta_Voc=-0.33%/C, Isc=8.98 A, STC=260.0 W, Area=1.63 m2.
Result: 14 panels max on 600 V (590.5 V); 31 panels for 8 kW (544 sq ft).
What Are the Published CEC Specifications for PEIMAR SG260P?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PEIMAR SG260P. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 235.7 W (90.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.81 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.98 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.98 V / 8.4 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.33 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.95% (1.63 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many PEIMAR SG260P Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PEIMAR SG260P (260.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.24 kW | 421 sq ft | $1,562 | $2,641 |
| 8 kW Class | 31 | 8.06 kW | 544 sq ft | $2,017 | $3,411 |
| 10 kW Class | 39 | 10.14 kW | 684 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?
All closely matched PEIMAR wattages and cosmetic trims sharing the PEIMAR SG260P architecture. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| PEIMAR SG250P | 250.0 W | 223.6 W | 36.5 V | 30.4 V | 15.37% |
| PEIMAR SG255P | 255.0 W | 231.0 W | 37.52 V | 30.5 V | 15.67% |
| PEIMAR SG260P | 260.0 W | 235.7 W | 37.81 V | 30.98 V | 15.95% |
| PEIMAR SG265P | 265.0 W | 240.3 W | 38.04 V | 31.18 V | 16.26% |
| PEIMAR SG270P | 270.0 W | 245.0 W | 38.29 V | 31.38 V | 16.56% |
How Many PEIMAR SG260P Modules Fit in a Cold-Weather String?
Maximum series module counts for PEIMAR SG260P from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.42 V | 13 panels | 564.5 V | 23 panels |
| -10 C (14 F) | 42.18 V | 14 panels | 590.5 V | 23 panels |
| 0 C (32 F) | 40.93 V | 14 panels | 573.0 V | 24 panels |
| 25 C (77 F STC) | 37.81 V | 15 panels | 567.2 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to PEIMAR SG260P?
Alternative CEC solar modules from competing brands near PEIMAR SG260P (260.0 W), including Auxin Solar AXN6M610T260. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6M610T260 Auxin Solar |
260.0 W | Tie (0 W) | 37.8 V | 15.87% | 89.6% |
| CSI Solar Co Ltd CS6P-260M CSI Solar Co Ltd |
260.0 W | Tie (0 W) | 37.8 V | 16.79% | 91.3% |
| CSI Solar Co Ltd CS6P-260MX CSI Solar Co Ltd |
260.0 W | Tie (0 W) | 37.8 V | 16.79% | 90.7% |
| Gintung Energy ASEC-260G6M6A Gintung Energy |
260.0 W | Tie (0 W) | 37.78 V | 16.14% | 88.1% |
What Are the Design Limits and Best-Fit Uses for PEIMAR SG260P?
Evaluate PEIMAR SG260P (260.0 W STC, 37.81 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SG260P reaches 43.42 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 544 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (544 sq ft).
- 2026 tax credit baseline: cash residential installs of PEIMAR SG260P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PEIMAR SG260P 8 kW Residential Fit
Needs 31 modules (544 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Auxin Solar AXN6M610T260.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 235.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PEIMAR SG260P by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
Why is PEIMAR SG260P PTC wattage (235.7 W) lower than STC (260.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 235.7 W PTC (90.7% retention) across PEIMAR SG260P's 1.63 m2 aperture.
Who should skip PEIMAR SG260P on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 31 PEIMAR SG260P panels (544 sq ft) leave unusable roof gaps vs. Auxin Solar AXN6M610T260.
What is the 1,000 V commercial string limit for PEIMAR SG260P?
On 1,000 V commercial inverters at -10 C (42.18 V cold Voc), PEIMAR SG260P fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting PEIMAR SG260P.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)