Skip to main content
WireAndSun
Calculators
CEC PV Module

PEIMAR SG235P — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SG235P is a 235.0 W STC (209.8 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.44% efficiency, 36.1 V Voc at 25 C, and 40.66 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
235.0 W
PTC Wattage
209.8 W
Voc @ 25C
36.1 V
Efficiency
14.44%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SG235P Compare Against Peer CEC Listings?

Solar engineering breakdown for PEIMAR SG235P: PTC thermal retention, roof footprint, and cold Voc string bounds. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Across 1,407 Multi-c-Si listings from PEIMAR and peers, PEIMAR SG235P stands 43.8 W below the 278.8 W Multi-c-Si median and typical 89.3% PTC-to-STC thermal output (209.8 W real-world rating). Sizing 6 kW (26 panels) to 10 kW (43 panels) yields $1,529-$2,530/yr in baseline US bill offset. Lower 36.1 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does PEIMAR SG235P Fall Across Listed CEC Models?

Distribution marker showing PEIMAR SG235P (235.0 W) relative to the 385.0 W all-CEC solar panel median. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SG235P (235.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SG235P: 235.0 W

What Dataset Percentiles Define PEIMAR SG235P?

Dataset percentiles tracking PEIMAR SG235P power output, thermal retention ratio, and aperture efficiency against 21,677 models. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

PEIMAR SG235P Engineering BenchmarksPercentile comparison of PEIMAR SG235P wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage235.0 WPTC/STC Retention89.3%Module Efficiency14.44%

What Do the Dataset Ranks Show for PEIMAR SG235P?

Benchmark highlights for PEIMAR SG235P covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #20,368 / 21,677

235.0 W STC · Higher Than 5.4%

235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,465

14.44% Aperture Efficiency

Power density 144.4 W/m2 (5.47 percentage points below 19.91% CEC median). PTC/STC ratio: 89.3% (rank #20,205).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.66 V at -10 C (569.2 V string) and 41.96 V at -20 C (14 max).

8 kW Reference Array

35 Panels = 8,225 W STC

Occupies 56.9 m2 (613 sq ft) producing 7,343 W PTC; NEC 690.8 OCPD floor is 13.65 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.1 * (1 + (-0.361/100) * (-10 - 25)) = 40.66 V | OCPD = 1.56 * 8.75 = 13.65 A

Inputs from CEC Modules.csv for PEIMAR SG235P: Voc=36.1 V, beta_Voc=-0.361%/C, Isc=8.75 A, STC=235.0 W, Area=1.627 m2.

Result: 14 panels max on 600 V (569.2 V); 35 panels for 8 kW (613 sq ft).

What Are the Published CEC Specifications for PEIMAR SG235P?

Official CEC datasheet figures for PEIMAR SG235P (Multi-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SG235P.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 235.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 209.8 W (89.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.75 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.0 V / 7.83 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.361 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.44% (1.627 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many PEIMAR SG235P Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many PEIMAR SG235P modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 26 6.11 kW 455 sq ft $1,529 $2,586
8 kW Class 35 8.22 kW 613 sq ft $2,057 $3,479
10 kW Class 43 10.11 kW 753 sq ft $2,530 $4,279

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

Consolidated PEIMAR wattage variants sharing the PEIMAR SG235P mechanical and cell layout. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the PEIMAR SG235P wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SG225P 225.0 W 200.6 W 35.8 V 29.6 V 13.83%
PEIMAR SG230P 230.0 W 205.2 W 36.0 V 29.8 V 14.14%
PEIMAR SG235P 235.0 W 209.8 W 36.1 V 30.0 V 14.44%
PEIMAR SG240P 240.0 W 214.4 W 36.2 V 30.2 V 14.75%
PEIMAR SG245P 245.0 W 219.0 W 36.4 V 30.3 V 15.06%

How Many PEIMAR SG235P Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on PEIMAR SG235P (40.66 V at 14 F). Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Computed from Voc=36.1V and beta_Voc=-0.361%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.96 V 14 panels 587.4 V 23 panels
-10 C (14 F) 40.66 V 14 panels 569.2 V 24 panels
0 C (32 F) 39.36 V 15 panels 590.4 V 25 panels
25 C (77 F STC) 36.1 V 16 panels 577.6 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SG235P?

Competing CEC solar panels closest to PEIMAR SG235P in nameplate wattage and Voc, starting with Anhui Rinengzhongtian Semiconductor Development QJP235-60.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Anhui Rinengzhongtian Semiconductor Development QJP235-60
Anhui Rinengzhongtian Semiconductor Development
235.0 W Tie (0 W) 36.1 V 14.44% 89.3%
Changzhou Nesl Solartech DJ-235P-ST15
Changzhou Nesl Solartech
235.0 W Tie (0 W) 36.2 V 14.39% 90.3%
Anhui Rinengzhongtian Semiconductor Development QJM235-60
Anhui Rinengzhongtian Semiconductor Development
235.0 W Tie (0 W) 36.65 V 14.44% 90.0%
Advance Power API-P235
Advance Power
235.0 W Tie (0 W) 36.72 V 14.35% 89.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SG235P?

Evaluate PEIMAR SG235P (235.0 W STC, 36.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SG235P reaches 41.96 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 613 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (613 sq ft).
  • 2026 tax credit baseline: cash residential installs of PEIMAR SG235P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SG235P 8 kW Residential Fit

Needs 35 modules (613 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJP235-60.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 209.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SG235P by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

What fuse or breaker size does NEC 690.8 require for PEIMAR SG235P?

Multiplying PEIMAR SG235P's 8.75 A short-circuit current by 1.56 equals 13.65 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for PEIMAR SG235P before finalizing component orders.

Can PEIMAR SG235P pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.66 V cold Voc at 14 F and handles 8.75 A Isc; string inverters cap PEIMAR SG235P at 14 panels on 600 V.

Is PEIMAR SG235P eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PEIMAR SG235P rely on utility bill offset (~$2,057/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.