Skip to main content
WireAndSun
Calculators
CEC PV Module

PEIMAR SG200M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SG200M is a 200.0 W STC (178.0 W PTC) Mono-c-Si solar module ranking #21,027 of 21,677 CEC listings (below all-CEC median; higher than 2.7% of peers). It delivers 15.67% efficiency, 45.7 V Voc at 25 C, and 51.57 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
200.0 W
PTC Wattage
178.0 W
Voc @ 25C
45.7 V
Efficiency
15.67%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SG200M Compare Against Peer CEC Listings?

Engineering position of PEIMAR SG200M (200.0 W STC) vs. Anhui Rinengzhongtian Semiconductor Development QJM200-72 across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, PEIMAR SG200M pairs typical 89.0% PTC-to-STC thermal output (178.0 W real-world rating) with 45.7 V nominal Voc. An 8 kW residential build (8,000 W DC, 7,120 W PTC) saves ~$2,002/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Anhui Rinengzhongtian Semiconductor Development QJM200-72 offers a 200.0 W alternative.

Where Does PEIMAR SG200M Fall Across Listed CEC Models?

Plots PEIMAR SG200M at 200.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SG200M (200.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SG200M: 200.0 W

What Dataset Percentiles Define PEIMAR SG200M?

Benchmarks PEIMAR SG200M on STC wattage, thermal PTC/STC retention, and 15.67 aperture conversion efficiency against CEC peers.

PEIMAR SG200M Engineering BenchmarksPercentile comparison of PEIMAR SG200M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage200.0 WPTC/STC Retention89.0%Module Efficiency15.67%

What Do the Dataset Ranks Show for PEIMAR SG200M?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for PEIMAR SG200M by PEIMAR.

Rank #21,027 / 21,677

200.0 W STC · Higher Than 2.7%

200.0 W STC (-185.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,676

15.67% Aperture Efficiency

Power density 156.6 W/m2 (4.24 percentage points below 19.91% CEC median). PTC/STC ratio: 89.0% (rank #20,637).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.57 V at -10 C (567.3 V string) and 53.25 V at -20 C (11 max).

8 kW Reference Array

40 Panels = 8,000 W STC

Occupies 51.1 m2 (550 sq ft) producing 7,120 W PTC; NEC 690.8 OCPD floor is 9.28 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.7 * (1 + (-0.367/100) * (-10 - 25)) = 51.57 V | OCPD = 1.56 * 5.95 = 9.28 A

Inputs from CEC Modules.csv for PEIMAR SG200M: Voc=45.7 V, beta_Voc=-0.367%/C, Isc=5.95 A, STC=200.0 W, Area=1.277 m2.

Result: 11 panels max on 600 V (567.3 V); 40 panels for 8 kW (550 sq ft).

What Are the Published CEC Specifications for PEIMAR SG200M?

Laboratory test ratings recorded for PEIMAR SG200M (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SG200M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 200.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 178.0 W (89.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 5.95 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.12 V / 5.54 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.367 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.67% (1.277 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SG200M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (550 sq ft at 8 kW), and estimated Year-1 electric bill offset for PEIMAR SG200M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 30 6.0 kW 412 sq ft $1,502 $2,539
8 kW Class 40 8.0 kW 550 sq ft $2,002 $3,386
10 kW Class 50 10.0 kW 687 sq ft $2,503 $4,232

How Many PEIMAR SG200M Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for PEIMAR SG200M (beta_Voc -0.367%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=45.7V and beta_Voc=-0.367%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.25 V 11 panels 585.8 V 18 panels
-10 C (14 F) 51.57 V 11 panels 567.3 V 19 panels
0 C (32 F) 49.89 V 12 panels 598.7 V 20 panels
25 C (77 F STC) 45.7 V 13 panels 594.1 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SG200M?

Closest cross-brand CEC competitors to PEIMAR SG200M matched near 200.0 W STC and 45.7 V Voc, led by Anhui Rinengzhongtian Semiconductor Development QJM200-72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Anhui Rinengzhongtian Semiconductor Development QJM200-72
Anhui Rinengzhongtian Semiconductor Development
200.0 W Tie (0 W) 45.7 V 15.67% 89.0%
AXITEC AC-200M/125-72S
AXITEC
200.0 W Tie (0 W) 45.87 V 15.67% 89.9%
Eoplly New Energy Technology EP125M/72-205W
Eoplly New Energy Technology
205.0 W +5.0 W 46.21 V 16.06% 89.0%
CSI Solar Co Ltd CS6P-200P
CSI Solar Co Ltd
200.0 W Tie (0 W) 36.2 V 12.43% 91.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SG200M?

Evaluate PEIMAR SG200M (200.0 W STC, 45.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SG200M reaches 53.25 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 40 panels for an 8 kW build require 550 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 40 panels (550 sq ft).
  • 2026 tax credit baseline: cash residential installs of PEIMAR SG200M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SG200M 8 kW Residential Fit

Needs 40 modules (550 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJM200-72.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 178.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SG200M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

What fuse or breaker size does NEC 690.8 require for PEIMAR SG200M?

Multiplying PEIMAR SG200M's 5.95 A short-circuit current by 1.56 equals 9.28 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for PEIMAR SG200M before finalizing component orders.

Can PEIMAR SG200M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.57 V cold Voc at 14 F and handles 5.95 A Isc; string inverters cap PEIMAR SG200M at 11 panels on 600 V.

Is PEIMAR SG200M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PEIMAR SG200M rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.