PEIMAR SF390M is a 390.0 W STC (364.5 W PTC) Mono-c-Si solar module ranking #10,321 of 21,677 CEC listings (top 49.5%; higher than 50.5% of peers). It delivers 20.21% efficiency, 45.12 V Voc at 25 C, and 49.32 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 390.0 W
- PTC Wattage
- 364.5 W
- Voc @ 25C
- 45.12 V
- Efficiency
- 20.21%
How Does PEIMAR SF390M Compare Against Peer CEC Listings?
How PEIMAR PEIMAR SF390M handles rooftop heat (364.5 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, PEIMAR SF390M exhibits 10.98 A short-circuit current, requiring a 17.13 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #10,321 of 21,677 (20.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 40.5 m2 for an 8 kW system (26 panels for 10 kW). Mid-range 45.12 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.
Where Does PEIMAR SF390M Fall Across Listed CEC Models?
Where PEIMAR SF390M (390.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define PEIMAR SF390M?
Percentile placement of PEIMAR SF390M across power density (202.1 W/m2), thermal retention, and nameplate STC wattage. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Do the Dataset Ranks Show for PEIMAR SF390M?
Four critical engineering numbers homeowners and solar installers check first when reviewing PEIMAR SF390M specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
Top 49.5% STC Output
390.0 W STC (+5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.21% Aperture Efficiency
Power density 202.1 W/m2 (0.30 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 49.32 V at -10 C (591.8 V string) and 50.52 V at -20 C (11 max).
21 Panels = 8,190 W STC
Occupies 40.5 m2 (436 sq ft) producing 7,654 W PTC; NEC 690.8 OCPD floor is 17.13 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.12 * (1 + (-0.266/100) * (-10 - 25)) = 49.32 V | OCPD = 1.56 * 10.98 = 17.13 A
Inputs from CEC Modules.csv for PEIMAR SF390M: Voc=45.12 V, beta_Voc=-0.266%/C, Isc=10.98 A, STC=390.0 W, Area=1.93 m2.
Result: 12 panels max on 600 V (591.8 V); 21 panels for 8 kW (436 sq ft).
What Are the Published CEC Specifications for PEIMAR SF390M?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PEIMAR SF390M. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 390.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 364.5 W (93.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.12 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.98 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.6 V / 10.37 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.266 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.21% (1.93 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Monofacial backsheet |
How Many PEIMAR SF390M Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PEIMAR SF390M (390.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.24 kW | 332 sq ft | $1,562 | $2,641 |
| 8 kW Class | 21 | 8.19 kW | 436 sq ft | $2,050 | $3,466 |
| 10 kW Class | 26 | 10.14 kW | 540 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?
All closely matched PEIMAR wattages and cosmetic trims sharing the PEIMAR SF390M architecture. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| PEIMAR SF380M | 380.0 W | 354.9 W | 44.64 V | 37.2 V | 19.69% |
| PEIMAR SF385M | 385.0 W | 359.7 W | 44.88 V | 37.4 V | 19.95% |
| PEIMAR SF390M | 390.0 W | 364.5 W | 45.12 V | 37.6 V | 20.21% |
| PEIMAR SF395M | 395.0 W | 369.2 W | 45.36 V | 37.8 V | 20.47% |
How Many PEIMAR SF390M Modules Fit in a Cold-Weather String?
Maximum series module counts for PEIMAR SF390M from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 50.52 V | 11 panels | 555.7 V | 19 panels |
| -10 C (14 F) | 49.32 V | 12 panels | 591.8 V | 20 panels |
| 0 C (32 F) | 48.12 V | 12 panels | 577.4 V | 20 panels |
| 25 C (77 F STC) | 45.12 V | 13 panels | 586.6 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to PEIMAR SF390M?
Alternative CEC solar modules from competing brands near PEIMAR SF390M (390.0 W), including CSI Solar Co Ltd CS3W-390P.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3W-390P CSI Solar Co Ltd |
390.0 W | Tie (0 W) | 46.8 V | 18.22% | 92.4% |
| EMMVEE Photovoltaic Power Private Limited E385M72-B EMMVEE Photovoltaic Power Private Limited |
385.0 W | -5.0 W | 45.9 V | 19.32% | 91.5% |
| CSI Solar Co Ltd CS3N-385MS {Blk} CSI Solar Co Ltd |
385.0 W | -5.0 W | 43.9 V | 19.54% | 93.4% |
| CSI Solar Co Ltd CS3N-385MS {Wht} CSI Solar Co Ltd |
385.0 W | -5.0 W | 43.9 V | 19.54% | 93.4% |
What Are the Design Limits and Best-Fit Uses for PEIMAR SF390M?
Evaluate PEIMAR SF390M (390.0 W STC, 45.12 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SF390M reaches 50.52 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 436 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (436 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of PEIMAR SF390M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PEIMAR SF390M 8 kW Residential Fit
Needs 21 modules (436 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3W-390P.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 364.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PEIMAR SF390M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
Why is PEIMAR SF390M PTC wattage (364.5 W) lower than STC (390.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 364.5 W PTC (93.5% retention) across PEIMAR SF390M's 1.93 m2 aperture.
Who should skip PEIMAR SF390M on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 PEIMAR SF390M panels (436 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3W-390P.
What is the 1,000 V commercial string limit for PEIMAR SF390M?
On 1,000 V commercial inverters at -10 C (49.32 V cold Voc), PEIMAR SF390M fits up to 20 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting PEIMAR SF390M.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)