PEIMAR SE455M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SE455M is a 455.0 W STC (427.6 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 21.67% efficiency, 41.3 V Voc at 25 C, and 45.09 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
455.0 W
PTC Wattage
427.6 W
Voc @ 25C
41.3 V
Efficiency
21.67%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SE455M Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for PEIMAR SE455M (Mono-c-Si) residential solar systems. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

PEIMAR SE455M delivers 216.7 W/m2 (1.76 percentage points above 19.91% CEC median) and strong 94.0% PTC-to-STC heat retention (#4,745 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 18 panels (407 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 46.17 V per unit, capping 600 V circuits at 12 panels. Compare specs directly with ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120 (455.0 W).

Where Does PEIMAR SE455M Fall Across Listed CEC Models?

Comparison of PEIMAR SE455M (455.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SE455M (455.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SE455M: 455.0 W

What Dataset Percentiles Define PEIMAR SE455M?

Relative ranking of PEIMAR SE455M across nameplate watts, 94.0% PTC thermal ratio, and module aperture efficiency. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

PEIMAR SE455M Engineering BenchmarksPercentile comparison of PEIMAR SE455M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage455.0 WPTC/STC Retention94.0%Module Efficiency21.67%

What Do the Dataset Ranks Show for PEIMAR SE455M?

Summary of PEIMAR SE455M output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.

Rank #5,417 / 21,677

Top 26.2% STC Output

455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,970

21.67% Aperture Efficiency

Power density 216.7 W/m2 (1.76 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.09 V at -10 C (586.2 V string) and 46.17 V at -20 C (12 max).

8 kW Reference Array

18 Panels = 8,190 W STC

Occupies 37.8 m2 (407 sq ft) producing 7,697 W PTC; NEC 690.8 OCPD floor is 21.75 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.3 * (1 + (-0.262/100) * (-10 - 25)) = 45.09 V | OCPD = 1.56 * 13.94 = 21.75 A

Inputs from CEC Modules.csv for PEIMAR SE455M: Voc=41.3 V, beta_Voc=-0.262%/C, Isc=13.94 A, STC=455.0 W, Area=2.1 m2.

Result: 13 panels max on 600 V (586.2 V); 18 panels for 8 kW (407 sq ft).

What Are the Published CEC Specifications for PEIMAR SE455M?

Complete CEC test sheet for PEIMAR SE455M including Isc (13.94 A), Voc (41.3 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SE455M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 455.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 427.6 W (94.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.94 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.94 V / 13.02 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.262 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.67% (2.1 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SE455M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using PEIMAR SE455M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.37 kW 316 sq ft $1,594 $2,696
8 kW Class 18 8.19 kW 407 sq ft $2,050 $3,466
10 kW Class 22 10.01 kW 497 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

Related PEIMAR power steps and black/silver trims consolidated into this PEIMAR SE455M series guide. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the PEIMAR SE455M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SE450M 450.0 W 422.7 W 41.2 V 34.85 V 21.43%
PEIMAR SE455M 455.0 W 427.6 W 41.3 V 34.94 V 21.67%
PEIMAR SE460M 460.0 W 432.4 W 41.4 V 35.08 V 21.9%

How Many PEIMAR SE455M Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for PEIMAR SE455M (41.3 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=41.3V and beta_Voc=-0.262%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.17 V 12 panels 554.0 V 21 panels
-10 C (14 F) 45.09 V 13 panels 586.2 V 22 panels
0 C (32 F) 44.01 V 13 panels 572.1 V 22 panels
25 C (77 F STC) 41.3 V 14 panels 578.2 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SE455M?

Four comparable CEC modules such as ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120 (455.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
455.0 W Tie (0 W) 41.3 V 21.26% 92.9%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120E
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
455.0 W Tie (0 W) 41.3 V 21.26% 92.7%
Changzhou EGing Photovoltaic Technology Co Ltd EG-455M60-HLV
Changzhou EGing Photovoltaic Technology Co Ltd
455.0 W Tie (0 W) 41.3 V 21.06% 93.8%
Global Power Services LLC GP455-60-182PMBB
Global Power Services LLC
455.0 W Tie (0 W) 41.3 V 21.06% 93.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SE455M?

Evaluate PEIMAR SE455M (455.0 W STC, 41.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SE455M reaches 46.17 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 407 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (407 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PEIMAR SE455M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SE455M 8 kW Residential Fit

Needs 18 modules (407 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 427.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SE455M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

How many PEIMAR SE455M panels fit on a 600 V winter solar string?

At -10 C (14 F), PEIMAR SE455M cold Voc rises from 41.3 V to 45.09 V (beta_Voc -0.262%/C), capping a 600 V string at 13 panels (586.2 V).

How much roof area does an 8 kW array of PEIMAR SE455M need?

An 8 kW DC system uses 18 PEIMAR SE455M modules (8,190 W STC / 7,697 W PTC), covering roughly 407 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

How does PEIMAR SE455M compare against ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120?

PEIMAR SE455M outputs 455.0 W STC (41.3 V Voc, rank #5,417 of 21,677), while ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120 delivers 455.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls