Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR SE410M is a 410.0 W STC (385.3 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.69% efficiency, 37.2 V Voc at 25 C, and 40.61 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
385.3 W
Voc @ 25C
37.2 V
Efficiency
21.69%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR SE410M Compare Against Peer CEC Listings?

How PEIMAR PEIMAR SE410M handles rooftop heat (385.3 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, PEIMAR SE410M exhibits 13.94 A short-circuit current, requiring a 21.75 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #8,539 of 21,677 (equal to the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 37.8 m2 for an 8 kW system (25 panels for 10 kW). Lower 37.2 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does PEIMAR SE410M Fall Across Listed CEC Models?

Where PEIMAR SE410M (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR SE410M (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR SE410M: 410.0 W

What Dataset Percentiles Define PEIMAR SE410M?

Percentile placement of PEIMAR SE410M across power density (216.9 W/m2), thermal retention, and nameplate STC wattage. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

PEIMAR SE410M Engineering BenchmarksPercentile comparison of PEIMAR SE410M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention94.0%Module Efficiency21.69%

What Do the Dataset Ranks Show for PEIMAR SE410M?

Four critical engineering numbers homeowners and solar installers check first when reviewing PEIMAR SE410M specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,894

21.69% Aperture Efficiency

Power density 216.9 W/m2 (1.78 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.61 V at -10 C (568.5 V string) and 41.59 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 37.8 m2 (407 sq ft) producing 7,706 W PTC; NEC 690.8 OCPD floor is 21.75 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.2 * (1 + (-0.262/100) * (-10 - 25)) = 40.61 V | OCPD = 1.56 * 13.94 = 21.75 A

Inputs from CEC Modules.csv for PEIMAR SE410M: Voc=37.2 V, beta_Voc=-0.262%/C, Isc=13.94 A, STC=410.0 W, Area=1.89 m2.

Result: 14 panels max on 600 V (568.5 V); 20 panels for 8 kW (407 sq ft).

What Are the Published CEC Specifications for PEIMAR SE410M?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PEIMAR SE410M. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR SE410M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 385.3 W (94.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.94 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.47 V / 13.02 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.262 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.69% (1.89 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR SE410M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PEIMAR SE410M (410.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 305 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 407 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 509 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

All closely matched PEIMAR wattages and cosmetic trims sharing the PEIMAR SE410M architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the PEIMAR SE410M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR SE400M 400.0 W 375.7 W 37.0 V 31.3 V 21.16%
PEIMAR SE405M 405.0 W 380.5 W 37.1 V 31.38 V 21.43%
PEIMAR SE410M 410.0 W 385.3 W 37.2 V 31.47 V 21.69%
PEIMAR SE415M 415.0 W 390.1 W 37.3 V 31.55 V 21.96%

How Many PEIMAR SE410M Modules Fit in a Cold-Weather String?

Maximum series module counts for PEIMAR SE410M from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.2V and beta_Voc=-0.262%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.59 V 14 panels 582.3 V 24 panels
-10 C (14 F) 40.61 V 14 panels 568.5 V 24 panels
0 C (32 F) 39.64 V 15 panels 594.6 V 25 panels
25 C (77 F STC) 37.2 V 16 panels 595.2 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR SE410M?

Alternative CEC solar modules from competing brands near PEIMAR SE410M (410.0 W), including CSI Solar Co Ltd CS6R-410MS-HL {Wht}.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS6R-410MS-HL {Wht}
CSI Solar Co Ltd
410.0 W Tie (0 W) 37.2 V 21.03% 94.2%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
410.0 W Tie (0 W) 37.23 V 21.24% 92.7%
Dehui Solar Power (Vietnam) CoLtd DH-M154W 410W
Dehui Solar Power (Vietnam) CoLtd
410.0 W Tie (0 W) 37.23 V 21.24% 92.7%
BYD Company Limited BYD410MLK-27
BYD Company Limited
410.0 W Tie (0 W) 37.14 V 21.13% 92.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR SE410M?

Evaluate PEIMAR SE410M (410.0 W STC, 37.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR SE410M reaches 41.59 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 407 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (407 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PEIMAR SE410M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR SE410M 8 kW Residential Fit

Needs 20 modules (407 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare CSI Solar Co Ltd CS6R-410MS-HL {Wht}.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 385.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR SE410M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Why is PEIMAR SE410M PTC wattage (385.3 W) lower than STC (410.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 385.3 W PTC (94.0% retention) across PEIMAR SE410M's 1.89 m2 aperture.

Who should skip PEIMAR SE410M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 PEIMAR SE410M panels (407 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS6R-410MS-HL {Wht}.

What is the 1,000 V commercial string limit for PEIMAR SE410M?

On 1,000 V commercial inverters at -10 C (40.61 V cold Voc), PEIMAR SE410M fits up to 24 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting PEIMAR SE410M.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.