Skip to main content
WireAndSun
Calculators
CEC PV Module

PEIMAR DR10H455M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR DR10H455M is a 455.0 W STC (426.5 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 21.26% efficiency, 41.3 V Voc at 25 C, and 45.72 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
455.0 W
PTC Wattage
426.5 W
Voc @ 25C
41.3 V
Efficiency
21.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR DR10H455M Compare Against Peer CEC Listings?

How PEIMAR PEIMAR DR10H455M handles rooftop heat (426.5 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, PEIMAR DR10H455M exhibits 13.93 A short-circuit current, requiring a 21.73 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #5,417 of 21,677 (45.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 38.5 m2 for an 8 kW system (22 panels for 10 kW). Mid-range 41.3 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

Where Does PEIMAR DR10H455M Fall Across Listed CEC Models?

Where PEIMAR DR10H455M (455.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR DR10H455M (455.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR DR10H455M: 455.0 W

What Dataset Percentiles Define PEIMAR DR10H455M?

Percentile placement of PEIMAR DR10H455M across power density (212.6 W/m2), thermal retention, and nameplate STC wattage. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

PEIMAR DR10H455M Engineering BenchmarksPercentile comparison of PEIMAR DR10H455M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage455.0 WPTC/STC Retention93.7%Module Efficiency21.26%

What Do the Dataset Ranks Show for PEIMAR DR10H455M?

Four critical engineering numbers homeowners and solar installers check first when reviewing PEIMAR DR10H455M specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #5,417 / 21,677

Top 26.2% STC Output

455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,361

21.26% Aperture Efficiency

Power density 212.6 W/m2 (1.35 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.72 V at -10 C (594.4 V string) and 46.99 V at -20 C (12 max).

8 kW Reference Array

18 Panels = 8,190 W STC

Occupies 38.5 m2 (415 sq ft) producing 7,677 W PTC; NEC 690.8 OCPD floor is 21.73 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.3 * (1 + (-0.306/100) * (-10 - 25)) = 45.72 V | OCPD = 1.56 * 13.93 = 21.73 A

Inputs from CEC Modules.csv for PEIMAR DR10H455M: Voc=41.3 V, beta_Voc=-0.306%/C, Isc=13.93 A, STC=455.0 W, Area=2.14 m2.

Result: 13 panels max on 600 V (594.4 V); 18 panels for 8 kW (415 sq ft).

What Are the Published CEC Specifications for PEIMAR DR10H455M?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for PEIMAR DR10H455M. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR DR10H455M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 455.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 426.5 W (93.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.93 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.1 V / 13.36 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.306 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.26% (2.14 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR DR10H455M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using PEIMAR DR10H455M (455.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.37 kW 322 sq ft $1,594 $2,696
8 kW Class 18 8.19 kW 415 sq ft $2,050 $3,466
10 kW Class 22 10.01 kW 507 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

All closely matched PEIMAR wattages and cosmetic trims sharing the PEIMAR DR10H455M architecture. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the PEIMAR DR10H455M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR DR10H450M 450.0 W 421.7 W 41.2 V 33.9 V 21.03%
PEIMAR DR10H455M 455.0 W 426.5 W 41.3 V 34.1 V 21.26%
PEIMAR DR10H460M 460.0 W 431.3 W 41.5 V 34.2 V 21.5%

How Many PEIMAR DR10H455M Modules Fit in a Cold-Weather String?

Maximum series module counts for PEIMAR DR10H455M from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=41.3V and beta_Voc=-0.306%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.99 V 12 panels 563.9 V 21 panels
-10 C (14 F) 45.72 V 13 panels 594.4 V 21 panels
0 C (32 F) 44.46 V 13 panels 578.0 V 22 panels
25 C (77 F STC) 41.3 V 14 panels 578.2 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR DR10H455M?

Alternative CEC solar modules from competing brands near PEIMAR DR10H455M (455.0 W), including ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
455.0 W Tie (0 W) 41.3 V 21.26% 92.9%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120E
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
455.0 W Tie (0 W) 41.3 V 21.26% 92.7%
Changzhou EGing Photovoltaic Technology Co Ltd EG-455M60-HLV
Changzhou EGing Photovoltaic Technology Co Ltd
455.0 W Tie (0 W) 41.3 V 21.06% 93.8%
Global Power Services LLC GP455-60-182PMBB
Global Power Services LLC
455.0 W Tie (0 W) 41.3 V 21.06% 93.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR DR10H455M?

Evaluate PEIMAR DR10H455M (455.0 W STC, 41.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR DR10H455M reaches 46.99 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (415 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PEIMAR DR10H455M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR DR10H455M 8 kW Residential Fit

Needs 18 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 426.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR DR10H455M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Why is PEIMAR DR10H455M PTC wattage (426.5 W) lower than STC (455.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 426.5 W PTC (93.7% retention) across PEIMAR DR10H455M's 2.14 m2 aperture.

Who should skip PEIMAR DR10H455M on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 PEIMAR DR10H455M panels (415 sq ft) leave unusable roof gaps vs. ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE455MD-120.

What is the 1,000 V commercial string limit for PEIMAR DR10H455M?

On 1,000 V commercial inverters at -10 C (45.72 V cold Voc), PEIMAR DR10H455M fits up to 21 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting PEIMAR DR10H455M.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.