PEIMAR DR10H445M is a 445.0 W STC (416.9 W PTC) Mono-c-Si solar module ranking #6,028 of 21,677 CEC listings (top 29.6%; higher than 70.4% of peers). It delivers 20.79% efficiency, 41.1 V Voc at 25 C, and 45.5 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 445.0 W
- PTC Wattage
- 416.9 W
- Voc @ 25C
- 41.1 V
- Efficiency
- 20.79%
How Does PEIMAR DR10H445M Compare Against Peer CEC Listings?
Engineering position of PEIMAR DR10H445M (445.0 W STC) vs. ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE445MD-120 across 5,889 CEC Mono-c-Si solar modules.
Built with 60 Mono-c-Si cells, PEIMAR DR10H445M pairs strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677) with 41.1 V nominal Voc. An 8 kW residential build (8,010 W DC, 7,504 W PTC) saves ~$2,005/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE445MD-120 offers a 445.0 W alternative.
Where Does PEIMAR DR10H445M Fall Across Listed CEC Models?
Plots PEIMAR DR10H445M at 445.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define PEIMAR DR10H445M?
Benchmarks PEIMAR DR10H445M on STC wattage, thermal PTC/STC retention, and 20.79 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for PEIMAR DR10H445M?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for PEIMAR DR10H445M by PEIMAR.
Top 29.6% STC Output
445.0 W STC (+60.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.79% Aperture Efficiency
Power density 207.9 W/m2 (0.88 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.5 V at -10 C (591.5 V string) and 46.76 V at -20 C (12 max).
18 Panels = 8,010 W STC
Occupies 38.5 m2 (415 sq ft) producing 7,504 W PTC; NEC 690.8 OCPD floor is 21.51 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.1 * (1 + (-0.306/100) * (-10 - 25)) = 45.5 V | OCPD = 1.56 * 13.79 = 21.51 A
Inputs from CEC Modules.csv for PEIMAR DR10H445M: Voc=41.1 V, beta_Voc=-0.306%/C, Isc=13.79 A, STC=445.0 W, Area=2.14 m2.
Result: 13 panels max on 600 V (591.5 V); 18 panels for 8 kW (415 sq ft).
What Are the Published CEC Specifications for PEIMAR DR10H445M?
Laboratory test ratings recorded for PEIMAR DR10H445M (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 445.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 416.9 W (93.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.79 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.8 V / 13.16 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.306 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.79% (2.14 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many PEIMAR DR10H445M Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (415 sq ft at 8 kW), and estimated Year-1 electric bill offset for PEIMAR DR10H445M.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.23 kW | 322 sq ft | $1,559 | $2,637 |
| 8 kW Class | 18 | 8.01 kW | 415 sq ft | $2,005 | $3,390 |
| 10 kW Class | 23 | 10.23 kW | 530 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?
Sibling wattage bins and frame colors grouped with PEIMAR DR10H445M under PEIMAR to prevent duplicate spec pages. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| PEIMAR DR10H440M | 440.0 W | 412.1 W | 41.0 V | 33.7 V | 20.56% |
| PEIMAR DR10H445M | 445.0 W | 416.9 W | 41.1 V | 33.8 V | 20.79% |
How Many PEIMAR DR10H445M Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for PEIMAR DR10H445M (beta_Voc -0.306%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.76 V | 12 panels | 561.1 V | 21 panels |
| -10 C (14 F) | 45.5 V | 13 panels | 591.5 V | 21 panels |
| 0 C (32 F) | 44.24 V | 13 panels | 575.1 V | 22 panels |
| 25 C (77 F STC) | 41.1 V | 14 panels | 575.4 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to PEIMAR DR10H445M?
Closest cross-brand CEC competitors to PEIMAR DR10H445M matched near 445.0 W STC and 41.1 V Voc, led by ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE445MD-120.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE445MD-120 ALTERNATIVE ENERGY (AE) SOLAR CO LTD |
445.0 W | Tie (0 W) | 41.1 V | 20.79% | 92.9% |
| ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE445MD-120E ALTERNATIVE ENERGY (AE) SOLAR CO LTD |
445.0 W | Tie (0 W) | 41.1 V | 20.79% | 92.6% |
| Aptos Solar Technology LLC DNA-120-MF10-445W Aptos Solar Technology LLC |
445.0 W | Tie (0 W) | 41.1 V | 20.79% | 93.7% |
| CertainTeed CTM10445HC11-06 CertainTeed |
445.0 W | Tie (0 W) | 41.1 V | 20.6% | 93.8% |
What Are the Design Limits and Best-Fit Uses for PEIMAR DR10H445M?
Evaluate PEIMAR DR10H445M (445.0 W STC, 41.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), PEIMAR DR10H445M reaches 46.76 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 415 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (415 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of PEIMAR DR10H445M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
PEIMAR DR10H445M 8 kW Residential Fit
Needs 18 modules (415 sq ft) with a 25 A string OCPD, offsetting ~$2,005/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE445MD-120.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 416.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for PEIMAR DR10H445M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What fuse or breaker size does NEC 690.8 require for PEIMAR DR10H445M?
Multiplying PEIMAR DR10H445M's 13.79 A short-circuit current by 1.56 equals 21.51 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker. Check local building department permit requirements for PEIMAR DR10H445M before finalizing component orders.
Can PEIMAR DR10H445M pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 45.5 V cold Voc at 14 F and handles 13.79 A Isc; string inverters cap PEIMAR DR10H445M at 13 panels on 600 V.
Is PEIMAR DR10H445M eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PEIMAR DR10H445M rely on utility bill offset (~$2,005/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)