PEIMAR DR10H410M — CEC Solar Module Specifications

Manufacturer: PEIMAR Registry: CEC Verified Engineering Specification

PEIMAR DR10H410M is a 410.0 W STC (384.3 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.13% efficiency, 37.1 V Voc at 25 C, and 41.07 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
384.3 W
Voc @ 25C
37.1 V
Efficiency
21.13%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does PEIMAR DR10H410M Compare Against Peer CEC Listings?

Engineering position of PEIMAR DR10H410M (410.0 W STC) vs. BYD Company Limited BYD410MLK-27 across 5,889 CEC Mono-c-Si solar modules.

Built with 54 Mono-c-Si cells, PEIMAR DR10H410M pairs strong 93.7% PTC-to-STC heat retention (#6,162 of 21,677) with 37.1 V nominal Voc. An 8 kW residential build (8,200 W DC, 7,686 W PTC) saves ~$2,052/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer BYD Company Limited BYD410MLK-27 offers a 410.0 W alternative.

Where Does PEIMAR DR10H410M Fall Across Listed CEC Models?

Plots PEIMAR DR10H410M at 410.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where PEIMAR DR10H410M (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCPEIMAR DR10H410M: 410.0 W

What Dataset Percentiles Define PEIMAR DR10H410M?

Benchmarks PEIMAR DR10H410M on STC wattage, thermal PTC/STC retention, and 21.13 aperture conversion efficiency against CEC peers.

PEIMAR DR10H410M Engineering BenchmarksPercentile comparison of PEIMAR DR10H410M wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention93.7%Module Efficiency21.13%

What Do the Dataset Ranks Show for PEIMAR DR10H410M?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for PEIMAR DR10H410M by PEIMAR.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,767

21.13% Aperture Efficiency

Power density 211.3 W/m2 (1.22 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.07 V at -10 C (575.0 V string) and 42.21 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 38.8 m2 (418 sq ft) producing 7,686 W PTC; NEC 690.8 OCPD floor is 21.72 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.1 * (1 + (-0.306/100) * (-10 - 25)) = 41.07 V | OCPD = 1.56 * 13.92 = 21.72 A

Inputs from CEC Modules.csv for PEIMAR DR10H410M: Voc=37.1 V, beta_Voc=-0.306%/C, Isc=13.92 A, STC=410.0 W, Area=1.94 m2.

Result: 14 panels max on 600 V (575.0 V); 20 panels for 8 kW (418 sq ft).

What Are the Published CEC Specifications for PEIMAR DR10H410M?

Laboratory test ratings recorded for PEIMAR DR10H410M (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for PEIMAR DR10H410M.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 384.3 W (93.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.92 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.6 V / 13.39 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.306 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.13% (1.94 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many PEIMAR DR10H410M Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (418 sq ft at 8 kW), and estimated Year-1 electric bill offset for PEIMAR DR10H410M.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 313 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 418 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 522 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This PEIMAR Series?

Sibling wattage bins and frame colors grouped with PEIMAR DR10H410M under PEIMAR to prevent duplicate spec pages. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the PEIMAR DR10H410M wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
PEIMAR DR10H400M 400.0 W 374.7 W 37.0 V 30.4 V 20.62%
PEIMAR DR10H405M 405.0 W 379.5 W 37.1 V 30.5 V 20.88%
PEIMAR DR10H410M 410.0 W 384.3 W 37.1 V 30.6 V 21.13%
PEIMAR DR10H415M 415.0 W 389.1 W 37.3 V 30.8 V 21.39%

How Many PEIMAR DR10H410M Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for PEIMAR DR10H410M (beta_Voc -0.306%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.1V and beta_Voc=-0.306%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.21 V 14 panels 590.9 V 23 panels
-10 C (14 F) 41.07 V 14 panels 575.0 V 24 panels
0 C (32 F) 39.94 V 15 panels 599.1 V 25 panels
25 C (77 F STC) 37.1 V 16 panels 593.6 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to PEIMAR DR10H410M?

Closest cross-brand CEC competitors to PEIMAR DR10H410M matched near 410.0 W STC and 37.1 V Voc, led by BYD Company Limited BYD410MLK-27.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
BYD Company Limited BYD410MLK-27
BYD Company Limited
410.0 W Tie (0 W) 37.14 V 21.13% 92.7%
CSI Solar Co Ltd CS6R-410MS-HL {Wht}
CSI Solar Co Ltd
410.0 W Tie (0 W) 37.2 V 21.03% 94.2%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
410.0 W Tie (0 W) 37.23 V 21.24% 92.7%
Dehui Solar Power (Vietnam) CoLtd DH-M154W 410W
Dehui Solar Power (Vietnam) CoLtd
410.0 W Tie (0 W) 37.23 V 21.24% 92.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for PEIMAR DR10H410M?

Evaluate PEIMAR DR10H410M (410.0 W STC, 37.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), PEIMAR DR10H410M reaches 42.21 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of PEIMAR DR10H410M carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

PEIMAR DR10H410M 8 kW Residential Fit

Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare BYD Company Limited BYD410MLK-27.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 384.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for PEIMAR DR10H410M by PEIMAR grounded in CEC test data and NEC 690.7/690.8 limits. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

What fuse or breaker size does NEC 690.8 require for PEIMAR DR10H410M?

Multiplying PEIMAR DR10H410M's 13.92 A short-circuit current by 1.56 equals 21.72 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker. Check local building department permit requirements for PEIMAR DR10H410M before finalizing component orders.

Can PEIMAR DR10H410M pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.07 V cold Voc at 14 F and handles 13.92 A Isc; string inverters cap PEIMAR DR10H410M at 14 panels on 600 V.

Is PEIMAR DR10H410M eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of PEIMAR DR10H410M rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.