Skip to main content
WireAndSun
Calculators
CEC PV Module

LOF SOLAR CORP LOF-MH82-C410 — CEC Solar Module Specifications

Manufacturer: LOF SOLAR CORP Registry: CEC Verified Engineering Specification

LOF SOLAR CORP LOF-MH82-C410 is a 410.0 W STC (379.0 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 20.71% efficiency, 44.9 V Voc at 25 C, and 49.98 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
379.0 W
Voc @ 25C
44.9 V
Efficiency
20.71%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does LOF SOLAR CORP LOF-MH82-C410 Compare Against Peer CEC Listings?

Solar engineering breakdown for LOF SOLAR CORP LOF-MH82-C410: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from LOF SOLAR CORP and peers, LOF SOLAR CORP LOF-MH82-C410 stands equal to the 410.0 W Mono-c-Si median and strong 92.4% PTC-to-STC heat retention (#12,969 of 21,677). Sizing 6 kW (15 panels) to 10 kW (25 panels) yields $1,539-$2,565/yr in baseline US bill offset. Mid-range 44.9 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does LOF SOLAR CORP LOF-MH82-C410 Fall Across Listed CEC Models?

Distribution marker showing LOF SOLAR CORP LOF-MH82-C410 (410.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where LOF SOLAR CORP LOF-MH82-C410 (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCLOF SOLAR CORP LOF: 410.0 W

What Dataset Percentiles Define LOF SOLAR CORP LOF-MH82-C410?

Dataset percentiles tracking LOF SOLAR CORP LOF-MH82-C410 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

LOF SOLAR CORP LOF-MH82-C410 Engineering BenchmarksPercentile comparison of LOF SOLAR CORP LOF-MH82-C410 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention92.4%Module Efficiency20.71%

What Do the Dataset Ranks Show for LOF SOLAR CORP LOF-MH82-C410?

Benchmark highlights for LOF SOLAR CORP LOF-MH82-C410 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,667

20.71% Aperture Efficiency

Power density 207.1 W/m2 (0.80 percentage points above 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.98 V at -10 C (599.8 V string) and 51.43 V at -20 C (11 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 39.6 m2 (426 sq ft) producing 7,580 W PTC; NEC 690.8 OCPD floor is 17.57 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.9 * (1 + (-0.323/100) * (-10 - 25)) = 49.98 V | OCPD = 1.56 * 11.26 = 17.57 A

Inputs from CEC Modules.csv for LOF SOLAR CORP LOF-MH82-C410: Voc=44.9 V, beta_Voc=-0.323%/C, Isc=11.26 A, STC=410.0 W, Area=1.98 m2.

Result: 12 panels max on 600 V (599.8 V); 20 panels for 8 kW (426 sq ft).

What Are the Published CEC Specifications for LOF SOLAR CORP LOF-MH82-C410?

Official CEC datasheet figures for LOF SOLAR CORP LOF-MH82-C410 (Mono-c-Si) used in utility interconnection and permit reviews. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Official California Energy Commission (NREL SAM) test parameters for LOF SOLAR CORP LOF-MH82-C410.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 379.0 W (92.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.26 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.2 V / 10.74 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.323 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.71% (1.98 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Monofacial backsheet

How Many LOF SOLAR CORP LOF-MH82-C410 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many LOF SOLAR CORP LOF-MH82-C410 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 320 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 426 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 533 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This LOF SOLAR CORP Series?

Consolidated LOF SOLAR CORP wattage variants sharing the LOF SOLAR CORP LOF-MH82-C410 mechanical and cell layout. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the LOF SOLAR CORP LOF-MH82-C410 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
LOF SOLAR CORP LOF-MH82-C400 400.0 W 369.4 W 44.6 V 37.9 V 20.2%
LOF SOLAR CORP LOF-MH82-C405 405.0 W 374.2 W 44.75 V 38.05 V 20.45%
LOF SOLAR CORP LOF-MH82-C410 410.0 W 379.0 W 44.9 V 38.2 V 20.71%
LOF SOLAR CORP LOF-MH82-C415 415.0 W 383.7 W 45.05 V 38.35 V 20.96%
LOF SOLAR CORP LOF-MH82-C420 420.0 W 388.5 W 45.2 V 38.5 V 21.21%

How Many LOF SOLAR CORP LOF-MH82-C410 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on LOF SOLAR CORP LOF-MH82-C410 (49.98 V at 14 F).

Computed from Voc=44.9V and beta_Voc=-0.323%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.43 V 11 panels 565.7 V 19 panels
-10 C (14 F) 49.98 V 12 panels 599.8 V 20 panels
0 C (32 F) 48.53 V 12 panels 582.4 V 20 panels
25 C (77 F STC) 44.9 V 13 panels 583.7 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to LOF SOLAR CORP LOF-MH82-C410?

Competing CEC solar panels closest to LOF SOLAR CORP LOF-MH82-C410 in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3N-410MS {Blk}.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3N-410MS {Blk}
CSI Solar Co Ltd
410.0 W Tie (0 W) 44.9 V 20.81% 93.5%
CSI Solar Co Ltd CS3N-405MS {Wht}
CSI Solar Co Ltd
405.0 W -5.0 W 44.7 V 20.56% 93.5%
CSI Solar Co Ltd CS3W-410P
CSI Solar Co Ltd
410.0 W Tie (0 W) 47.6 V 19.16% 93.2%
AXITEC AC-410MH/144V
AXITEC
410.0 W Tie (0 W) 48.91 V 20.71% 93.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for LOF SOLAR CORP LOF-MH82-C410?

Evaluate LOF SOLAR CORP LOF-MH82-C410 (410.0 W STC, 44.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), LOF SOLAR CORP LOF-MH82-C410 reaches 51.43 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 426 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (426 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of LOF SOLAR CORP LOF-MH82-C410 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

LOF SOLAR CORP LOF-MH82-C410 8 kW Residential Fit

Needs 20 modules (426 sq ft) with a 20 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3N-410MS {Blk}.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 379.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for LOF SOLAR CORP LOF-MH82-C410 by LOF SOLAR CORP grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for LOF SOLAR CORP LOF-MH82-C410?

Multiplying LOF SOLAR CORP LOF-MH82-C410's 11.26 A short-circuit current by 1.56 equals 17.57 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can LOF SOLAR CORP LOF-MH82-C410 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 49.98 V cold Voc at 14 F and handles 11.26 A Isc; string inverters cap LOF SOLAR CORP LOF-MH82-C410 at 12 panels on 600 V.

Is LOF SOLAR CORP LOF-MH82-C410 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of LOF SOLAR CORP LOF-MH82-C410 rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.