Skip to main content
WireAndSun
Calculators
CEC PV Module

LOF SOLAR CORP LOF-MH92-C435 — CEC Solar Module Specifications

Manufacturer: LOF SOLAR CORP Registry: CEC Verified Engineering Specification

LOF SOLAR CORP LOF-MH92-C435 is a 435.0 W STC (401.8 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 20.23% efficiency, 48.75 V Voc at 25 C, and 54.26 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
435.0 W
PTC Wattage
401.8 W
Voc @ 25C
48.75 V
Efficiency
20.23%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does LOF SOLAR CORP LOF-MH92-C435 Compare Against Peer CEC Listings?

Solar engineering breakdown for LOF SOLAR CORP LOF-MH92-C435: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from LOF SOLAR CORP and peers, LOF SOLAR CORP LOF-MH92-C435 stands 25.0 W above the 410.0 W Mono-c-Si median and strong 92.4% PTC-to-STC heat retention (#12,969 of 21,677). Sizing 6 kW (14 panels) to 10 kW (23 panels) yields $1,524-$2,505/yr in baseline US bill offset. Higher 48.75 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does LOF SOLAR CORP LOF-MH92-C435 Fall Across Listed CEC Models?

Distribution marker showing LOF SOLAR CORP LOF-MH92-C435 (435.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where LOF SOLAR CORP LOF-MH92-C435 (435.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCLOF SOLAR CORP LOF: 435.0 W

What Dataset Percentiles Define LOF SOLAR CORP LOF-MH92-C435?

Dataset percentiles tracking LOF SOLAR CORP LOF-MH92-C435 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

LOF SOLAR CORP LOF-MH92-C435 Engineering BenchmarksPercentile comparison of LOF SOLAR CORP LOF-MH92-C435 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage435.0 WPTC/STC Retention92.4%Module Efficiency20.23%

What Do the Dataset Ranks Show for LOF SOLAR CORP LOF-MH92-C435?

Benchmark highlights for LOF SOLAR CORP LOF-MH92-C435 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #6,850 / 21,677

Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,658

20.23% Aperture Efficiency

Power density 202.3 W/m2 (0.32 percentage points above 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.26 V at -10 C (596.9 V string) and 55.84 V at -20 C (10 max).

8 kW Reference Array

19 Panels = 8,265 W STC

Occupies 40.9 m2 (440 sq ft) producing 7,634 W PTC; NEC 690.8 OCPD floor is 17.16 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.75 * (1 + (-0.323/100) * (-10 - 25)) = 54.26 V | OCPD = 1.56 * 11.0 = 17.16 A

Inputs from CEC Modules.csv for LOF SOLAR CORP LOF-MH92-C435: Voc=48.75 V, beta_Voc=-0.323%/C, Isc=11.0 A, STC=435.0 W, Area=2.15 m2.

Result: 11 panels max on 600 V (596.9 V); 19 panels for 8 kW (440 sq ft).

What Are the Published CEC Specifications for LOF SOLAR CORP LOF-MH92-C435?

Official CEC datasheet figures for LOF SOLAR CORP LOF-MH92-C435 (Mono-c-Si) used in utility interconnection and permit reviews. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for LOF SOLAR CORP LOF-MH92-C435.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 435.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 401.8 W (92.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.75 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.0 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.4 V / 10.51 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.323 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.23% (2.15 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many LOF SOLAR CORP LOF-MH92-C435 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many LOF SOLAR CORP LOF-MH92-C435 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.09 kW 324 sq ft $1,524 $2,577
8 kW Class 19 8.27 kW 440 sq ft $2,070 $3,500
10 kW Class 23 10.01 kW 532 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This LOF SOLAR CORP Series?

Consolidated LOF SOLAR CORP wattage variants sharing the LOF SOLAR CORP LOF-MH92-C435 mechanical and cell layout. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the LOF SOLAR CORP LOF-MH92-C435 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
LOF SOLAR CORP LOF-MH92-C425 425.0 W 392.3 W 48.45 V 41.1 V 19.77%
LOF SOLAR CORP LOF-MH92-C430 430.0 W 397.0 W 48.6 V 41.25 V 20.0%
LOF SOLAR CORP LOF-MH92-C435 435.0 W 401.8 W 48.75 V 41.4 V 20.23%
LOF SOLAR CORP LOF-MH92-C440 440.0 W 406.5 W 48.9 V 41.55 V 20.47%
LOF SOLAR CORP LOF-MH92-C445 445.0 W 411.3 W 49.05 V 41.7 V 20.7%

How Many LOF SOLAR CORP LOF-MH92-C435 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on LOF SOLAR CORP LOF-MH92-C435 (54.26 V at 14 F).

Computed from Voc=48.75V and beta_Voc=-0.323%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.84 V 10 panels 558.4 V 17 panels
-10 C (14 F) 54.26 V 11 panels 596.9 V 18 panels
0 C (32 F) 52.69 V 11 panels 579.6 V 18 panels
25 C (77 F STC) 48.75 V 12 panels 585.0 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to LOF SOLAR CORP LOF-MH92-C435?

Competing CEC solar panels closest to LOF SOLAR CORP LOF-MH92-C435 in nameplate wattage and Voc, starting with Caterpillar Inc PVC435MP03H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Caterpillar Inc PVC435MP03H
Caterpillar Inc
435.0 W Tie (0 W) 48.7 V 20.52% 93.6%
CSI Solar Co Ltd CS3W-435P
CSI Solar Co Ltd
435.0 W Tie (0 W) 48.6 V 20.33% 92.4%
Boviet Solar Technology Co Ltd BVM6612M-435S-H-HC
Boviet Solar Technology Co Ltd
435.0 W Tie (0 W) 48.45 V 19.77% 93.7%
AXITEC AC-435MB/144V
AXITEC
435.0 W Tie (0 W) 49.1 V 20.33% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for LOF SOLAR CORP LOF-MH92-C435?

Evaluate LOF SOLAR CORP LOF-MH92-C435 (435.0 W STC, 48.75 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), LOF SOLAR CORP LOF-MH92-C435 reaches 55.84 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 440 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (440 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of LOF SOLAR CORP LOF-MH92-C435 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

LOF SOLAR CORP LOF-MH92-C435 8 kW Residential Fit

Needs 19 modules (440 sq ft) with a 20 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Caterpillar Inc PVC435MP03H.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 401.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for LOF SOLAR CORP LOF-MH92-C435 by LOF SOLAR CORP grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for LOF SOLAR CORP LOF-MH92-C435?

Multiplying LOF SOLAR CORP LOF-MH92-C435's 11.0 A short-circuit current by 1.56 equals 17.16 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can LOF SOLAR CORP LOF-MH92-C435 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.26 V cold Voc at 14 F and handles 11.0 A Isc; string inverters cap LOF SOLAR CORP LOF-MH92-C435 at 11 panels on 600 V.

Is LOF SOLAR CORP LOF-MH92-C435 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of LOF SOLAR CORP LOF-MH92-C435 rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.