Skip to main content
WireAndSun
Calculators
CEC PV Module

LOF SOLAR CORP LOF-MG81-C400 — CEC Solar Module Specifications

Manufacturer: LOF SOLAR CORP Registry: CEC Verified Engineering Specification

LOF SOLAR CORP LOF-MG81-C400 is a 400.0 W STC (367.2 W PTC) Mono-c-Si solar module ranking #9,407 of 21,677 CEC listings (top 45.5%; higher than 54.5% of peers). It delivers 20.2% efficiency, 49.4 V Voc at 25 C, and 55.16 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
400.0 W
PTC Wattage
367.2 W
Voc @ 25C
49.4 V
Efficiency
20.2%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does LOF SOLAR CORP LOF-MG81-C400 Compare Against Peer CEC Listings?

Engineering position of LOF SOLAR CORP LOF-MG81-C400 (400.0 W STC) vs. Boviet Solar Technology Co Ltd BVM6612M-400-H across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, LOF SOLAR CORP LOF-MG81-C400 pairs strong 91.8% PTC-to-STC heat retention (#14,745 of 21,677) with 49.4 V nominal Voc. An 8 kW residential build (8,000 W DC, 7,344 W PTC) saves ~$2,002/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Boviet Solar Technology Co Ltd BVM6612M-400-H offers a 400.0 W alternative.

Where Does LOF SOLAR CORP LOF-MG81-C400 Fall Across Listed CEC Models?

Plots LOF SOLAR CORP LOF-MG81-C400 at 400.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where LOF SOLAR CORP LOF-MG81-C400 (400.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCLOF SOLAR CORP LOF: 400.0 W

What Dataset Percentiles Define LOF SOLAR CORP LOF-MG81-C400?

Benchmarks LOF SOLAR CORP LOF-MG81-C400 on STC wattage, thermal PTC/STC retention, and 20.2 aperture conversion efficiency against CEC peers.

LOF SOLAR CORP LOF-MG81-C400 Engineering BenchmarksPercentile comparison of LOF SOLAR CORP LOF-MG81-C400 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage400.0 WPTC/STC Retention91.8%Module Efficiency20.2%

What Do the Dataset Ranks Show for LOF SOLAR CORP LOF-MG81-C400?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for LOF SOLAR CORP LOF-MG81-C400 by LOF SOLAR CORP.

Rank #9,407 / 21,677

Top 45.5% STC Output

400.0 W STC (+15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,795

20.2% Aperture Efficiency

Power density 202.0 W/m2 (0.29 percentage points above 19.91% CEC median). PTC/STC ratio: 91.8% (rank #14,745).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.16 V at -10 C (551.6 V string) and 56.8 V at -20 C (10 max).

8 kW Reference Array

20 Panels = 8,000 W STC

Occupies 39.6 m2 (426 sq ft) producing 7,344 W PTC; NEC 690.8 OCPD floor is 16.24 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.4 * (1 + (-0.333/100) * (-10 - 25)) = 55.16 V | OCPD = 1.56 * 10.41 = 16.24 A

Inputs from CEC Modules.csv for LOF SOLAR CORP LOF-MG81-C400: Voc=49.4 V, beta_Voc=-0.333%/C, Isc=10.41 A, STC=400.0 W, Area=1.98 m2.

Result: 10 panels max on 600 V (551.6 V); 20 panels for 8 kW (426 sq ft).

What Are the Published CEC Specifications for LOF SOLAR CORP LOF-MG81-C400?

Laboratory test ratings recorded for LOF SOLAR CORP LOF-MG81-C400 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for LOF SOLAR CORP LOF-MG81-C400.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 400.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 367.2 W (91.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.41 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.6 V / 9.85 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.333 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.2% (1.98 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many LOF SOLAR CORP LOF-MG81-C400 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (426 sq ft at 8 kW), and estimated Year-1 electric bill offset for LOF SOLAR CORP LOF-MG81-C400.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.0 kW 320 sq ft $1,502 $2,539
8 kW Class 20 8.0 kW 426 sq ft $2,002 $3,386
10 kW Class 25 10.0 kW 533 sq ft $2,503 $4,232

How Many LOF SOLAR CORP LOF-MG81-C400 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for LOF SOLAR CORP LOF-MG81-C400 (beta_Voc -0.333%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.4V and beta_Voc=-0.333%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.8 V 10 panels 568.0 V 17 panels
-10 C (14 F) 55.16 V 10 panels 551.6 V 18 panels
0 C (32 F) 53.51 V 11 panels 588.6 V 18 panels
25 C (77 F STC) 49.4 V 12 panels 592.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to LOF SOLAR CORP LOF-MG81-C400?

Closest cross-brand CEC competitors to LOF SOLAR CORP LOF-MG81-C400 matched near 400.0 W STC and 49.4 V Voc, led by Boviet Solar Technology Co Ltd BVM6612M-400-H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6612M-400-H
Boviet Solar Technology Co Ltd
400.0 W Tie (0 W) 49.2 V 20.62% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-W5-400-H
Boviet Solar Technology Co Ltd
400.0 W Tie (0 W) 49.2 V 20.62% 93.2%
Boviet Solar Technology Co Ltd BVM6612M-405L-H
Boviet Solar Technology Co Ltd
405.0 W +5.0 W 49.45 V 20.35% 93.3%
Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC
Boviet Solar Technology Co Ltd
405.0 W +5.0 W 49.45 V 19.95% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for LOF SOLAR CORP LOF-MG81-C400?

Evaluate LOF SOLAR CORP LOF-MG81-C400 (400.0 W STC, 49.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), LOF SOLAR CORP LOF-MG81-C400 reaches 56.8 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 426 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (426 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of LOF SOLAR CORP LOF-MG81-C400 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

LOF SOLAR CORP LOF-MG81-C400 8 kW Residential Fit

Needs 20 modules (426 sq ft) with a 20 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-400-H.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 367.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for LOF SOLAR CORP LOF-MG81-C400 by LOF SOLAR CORP grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for LOF SOLAR CORP LOF-MG81-C400?

Multiplying LOF SOLAR CORP LOF-MG81-C400's 10.41 A short-circuit current by 1.56 equals 16.24 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can LOF SOLAR CORP LOF-MG81-C400 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 55.16 V cold Voc at 14 F and handles 10.41 A Isc; string inverters cap LOF SOLAR CORP LOF-MG81-C400 at 10 panels on 600 V.

Is LOF SOLAR CORP LOF-MG81-C400 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of LOF SOLAR CORP LOF-MG81-C400 rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.