CSI Solar Co Ltd CS3W-410P is a 410.0 W STC (382.2 W PTC) Multi-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 19.16% efficiency, 47.6 V Voc at 25 C, and 52.08 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 382.2 W
- Voc @ 25C
- 47.6 V
- Efficiency
- 19.16%
How Does CSI Solar Co Ltd CS3W-410P Compare Against Peer CEC Listings?
Engineering position of CSI Solar Co Ltd CS3W-410P (410.0 W STC) vs. AXITEC AC-410MH/144V across 1,407 CEC Multi-c-Si solar modules.
Built with 72 Multi-c-Si cells, CSI Solar Co Ltd CS3W-410P pairs strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677) with 47.6 V nominal Voc. An 8 kW residential build (8,200 W DC, 7,644 W PTC) saves ~$2,052/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer AXITEC AC-410MH/144V offers a 410.0 W alternative.
Where Does CSI Solar Co Ltd CS3W-410P Fall Across Listed CEC Models?
Plots CSI Solar Co Ltd CS3W-410P at 410.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define CSI Solar Co Ltd CS3W-410P?
Benchmarks CSI Solar Co Ltd CS3W-410P on STC wattage, thermal PTC/STC retention, and 19.16 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for CSI Solar Co Ltd CS3W-410P?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for CSI Solar Co Ltd CS3W-410P by CSI Solar Co Ltd.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
19.16% Aperture Efficiency
Power density 191.6 W/m2 (0.75 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.08 V at -10 C (572.9 V string) and 53.36 V at -20 C (11 max).
20 Panels = 8,200 W STC
Occupies 42.8 m2 (461 sq ft) producing 7,644 W PTC; NEC 690.8 OCPD floor is 17.25 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.6 * (1 + (-0.269/100) * (-10 - 25)) = 52.08 V | OCPD = 1.56 * 11.06 = 17.25 A
Inputs from CEC Modules.csv for CSI Solar Co Ltd CS3W-410P: Voc=47.6 V, beta_Voc=-0.269%/C, Isc=11.06 A, STC=410.0 W, Area=2.14 m2.
Result: 11 panels max on 600 V (572.9 V); 20 panels for 8 kW (461 sq ft).
What Are the Published CEC Specifications for CSI Solar Co Ltd CS3W-410P?
Laboratory test ratings recorded for CSI Solar Co Ltd CS3W-410P (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 382.2 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.06 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.1 V / 10.49 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.269 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.16% (2.14 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many CSI Solar Co Ltd CS3W-410P Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (461 sq ft at 8 kW), and estimated Year-1 electric bill offset for CSI Solar Co Ltd CS3W-410P.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 346 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 461 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 576 sq ft | $2,565 | $4,338 |
Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?
Sibling wattage bins and frame colors grouped with CSI Solar Co Ltd CS3W-410P under CSI Solar Co Ltd to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3W-400P | 400.0 W | 369.9 W | 47.2 V | 38.7 V | 18.69% |
| CSI Solar Co Ltd CS3W-405P | 405.0 W | 374.7 W | 47.4 V | 38.9 V | 18.93% |
| CSI Solar Co Ltd CS3W-410P | 410.0 W | 382.2 W | 47.6 V | 39.1 V | 19.16% |
| CSI Solar Co Ltd CS3W-415P | 415.0 W | 386.9 W | 47.8 V | 39.3 V | 19.39% |
| CSI Solar Co Ltd CS3W-420P | 420.0 W | 391.7 W | 48.0 V | 39.5 V | 19.63% |
How Many CSI Solar Co Ltd CS3W-410P Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for CSI Solar Co Ltd CS3W-410P (beta_Voc -0.269%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.36 V | 11 panels | 587.0 V | 18 panels |
| -10 C (14 F) | 52.08 V | 11 panels | 572.9 V | 19 panels |
| 0 C (32 F) | 50.8 V | 11 panels | 558.8 V | 19 panels |
| 25 C (77 F STC) | 47.6 V | 12 panels | 571.2 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS3W-410P?
Closest cross-brand CEC competitors to CSI Solar Co Ltd CS3W-410P matched near 410.0 W STC and 47.6 V Voc, led by AXITEC AC-410MH/144V.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-410MH/144V AXITEC |
410.0 W | Tie (0 W) | 48.91 V | 20.71% | 93.5% |
| BYD Company Limited BYD400MIK-36 BYD Company Limited |
410.0 W | Tie (0 W) | 49.21 V | 20.4% | 94.0% |
| AXITEC AC-410MB/144V AXITEC |
410.0 W | Tie (0 W) | 49.3 V | 21.03% | 93.0% |
| Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W Dehui Solar Power (Vietnam) CoLtd |
410.0 W | Tie (0 W) | 49.4 V | 21.47% | 92.6% |
What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS3W-410P?
Evaluate CSI Solar Co Ltd CS3W-410P (410.0 W STC, 47.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS3W-410P reaches 53.36 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 461 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (461 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS3W-410P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CSI Solar Co Ltd CS3W-410P 8 kW Residential Fit
Needs 20 modules (461 sq ft) with a 20 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-410MH/144V.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 382.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CSI Solar Co Ltd CS3W-410P by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for CSI Solar Co Ltd CS3W-410P?
Multiplying CSI Solar Co Ltd CS3W-410P's 11.06 A short-circuit current by 1.56 equals 17.25 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can CSI Solar Co Ltd CS3W-410P pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 52.08 V cold Voc at 14 F and handles 11.06 A Isc; string inverters cap CSI Solar Co Ltd CS3W-410P at 11 panels on 600 V.
Is CSI Solar Co Ltd CS3W-410P eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of CSI Solar Co Ltd CS3W-410P rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)