JA Solar JAP6-72-290/MP is a 290.0 W STC (256.2 W PTC) Multi-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 14.96% efficiency, 45.5 V Voc at 25 C, and 50.98 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 290.0 W
- PTC Wattage
- 256.2 W
- Voc @ 25C
- 45.5 V
- Efficiency
- 14.96%
How Does JA Solar JAP6-72-290/MP Compare Against Peer CEC Listings?
Solar engineering breakdown for JA Solar JAP6-72-290/MP: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 1,407 Multi-c-Si listings from JA Solar and peers, JA Solar JAP6-72-290/MP stands 11.2 W above the 278.8 W Multi-c-Si median and typical 88.3% PTC-to-STC thermal output (256.2 W real-world rating). Sizing 6 kW (21 panels) to 10 kW (35 panels) yields $1,524-$2,540/yr in baseline US bill offset. Mid-range 45.5 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.
Where Does JA Solar JAP6-72-290/MP Fall Across Listed CEC Models?
Distribution marker showing JA Solar JAP6-72-290/MP (290.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define JA Solar JAP6-72-290/MP?
Dataset percentiles tracking JA Solar JAP6-72-290/MP power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for JA Solar JAP6-72-290/MP?
Benchmark highlights for JA Solar JAP6-72-290/MP covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
290.0 W STC · Higher Than 18.8%
290.0 W STC (-95.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
14.96% Aperture Efficiency
Power density 149.6 W/m2 (4.95 percentage points below 19.91% CEC median). PTC/STC ratio: 88.3% (rank #21,245).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.98 V at -10 C (560.8 V string) and 52.54 V at -20 C (11 max).
28 Panels = 8,120 W STC
Occupies 54.3 m2 (584 sq ft) producing 7,174 W PTC; NEC 690.8 OCPD floor is 13.48 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.5 * (1 + (-0.344/100) * (-10 - 25)) = 50.98 V | OCPD = 1.56 * 8.64 = 13.48 A
Inputs from CEC Modules.csv for JA Solar JAP6-72-290/MP: Voc=45.5 V, beta_Voc=-0.344%/C, Isc=8.64 A, STC=290.0 W, Area=1.938 m2.
Result: 11 panels max on 600 V (560.8 V); 28 panels for 8 kW (584 sq ft).
What Are the Published CEC Specifications for JA Solar JAP6-72-290/MP?
Official CEC datasheet figures for JA Solar JAP6-72-290/MP (Multi-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 290.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 256.2 W (88.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.64 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.34 V / 7.98 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.344 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.96% (1.938 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many JA Solar JAP6-72-290/MP Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many JA Solar JAP6-72-290/MP modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.09 kW | 438 sq ft | $1,524 | $2,577 |
| 8 kW Class | 28 | 8.12 kW | 584 sq ft | $2,032 | $3,437 |
| 10 kW Class | 35 | 10.15 kW | 730 sq ft | $2,540 | $4,296 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
Consolidated JA Solar wattage variants sharing the JA Solar JAP6-72-290/MP mechanical and cell layout. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAP6-72-280/MP | 280.0 W | 247.1 W | 45.33 V | 35.81 V | 14.44% |
| JA Solar JAP6-72-285/MP | 285.0 W | 251.6 W | 45.42 V | 36.08 V | 14.7% |
| JA Solar JAP6-72-290/MP | 290.0 W | 256.2 W | 45.5 V | 36.34 V | 14.96% |
| JA Solar JAP6-72-295/MP | 295.0 W | 260.7 W | 45.59 V | 36.56 V | 15.22% |
How Many JA Solar JAP6-72-290/MP Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAP6-72-290/MP (50.98 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.54 V | 11 panels | 577.9 V | 19 panels |
| -10 C (14 F) | 50.98 V | 11 panels | 560.8 V | 19 panels |
| 0 C (32 F) | 49.41 V | 12 panels | 592.9 V | 20 panels |
| 25 C (77 F STC) | 45.5 V | 13 panels | 591.5 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-72-290/MP?
Competing CEC solar panels closest to JA Solar JAP6-72-290/MP in nameplate wattage and Voc, starting with AXITEC AC-290M/156-72S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-290M/156-72S AXITEC |
290.0 W | Tie (0 W) | 44.98 V | 14.95% | 90.6% |
| Gintung Energy GTEC-290G6S Gintung Energy |
290.0 W | Tie (0 W) | 44.84 V | 14.83% | 89.7% |
| Gintung Energy GTEC-290G6M Gintung Energy |
290.0 W | Tie (0 W) | 44.61 V | 14.83% | 89.6% |
| Centrosolar America DM72 290 Centrosolar America |
290.0 W | Tie (0 W) | 44.4 V | 14.92% | 90.6% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-72-290/MP?
Evaluate JA Solar JAP6-72-290/MP (290.0 W STC, 45.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-72-290/MP reaches 52.54 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 584 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (584 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6-72-290/MP carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAP6-72-290/MP 8 kW Residential Fit
Needs 28 modules (584 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-290M/156-72S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 256.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAP6-72-290/MP by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for JA Solar JAP6-72-290/MP?
Multiplying JA Solar JAP6-72-290/MP's 8.64 A short-circuit current by 1.56 equals 13.48 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can JA Solar JAP6-72-290/MP pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 50.98 V cold Voc at 14 F and handles 8.64 A Isc; string inverters cap JA Solar JAP6-72-290/MP at 11 panels on 600 V.
Is JA Solar JAP6-72-290/MP eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAP6-72-290/MP rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)