JA Solar JAP6-60-275/4BB is a 275.0 W STC (254.9 W PTC) Multi-c-Si solar module ranking #18,259 of 21,677 CEC listings (below all-CEC median; higher than 14.3% of peers). It delivers 16.82% efficiency, 38.48 V Voc at 25 C, and 42.53 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 275.0 W
- PTC Wattage
- 254.9 W
- Voc @ 25C
- 38.48 V
- Efficiency
- 16.82%
How Does JA Solar JAP6-60-275/4BB Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for JA Solar JAP6-60-275/4BB (Multi-c-Si) residential solar systems.
Homeowners evaluating JA Solar JAP6-60-275/4BB need 22 panels for 6 kW or 30 panels (528 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (528 sq ft). Under NEC 690.7(A), beta_Voc (-0.301%/C) pushes open-circuit voltage to 42.53 V at 14 F and 43.69 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does JA Solar JAP6-60-275/4BB Fall Across Listed CEC Models?
Comparison of JA Solar JAP6-60-275/4BB (275.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define JA Solar JAP6-60-275/4BB?
Relative ranking of JA Solar JAP6-60-275/4BB across nameplate watts, 92.7% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for JA Solar JAP6-60-275/4BB?
Summary of JA Solar JAP6-60-275/4BB output rank, 8 kW array size (30 panels), efficiency rating, and 600 V string limit.
275.0 W STC · Higher Than 14.3%
275.0 W STC (-110.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.82% Aperture Efficiency
Power density 168.2 W/m2 (3.09 percentage points below 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.53 V at -10 C (595.4 V string) and 43.69 V at -20 C (13 max).
30 Panels = 8,250 W STC
Occupies 49.0 m2 (528 sq ft) producing 7,647 W PTC; NEC 690.8 OCPD floor is 14.45 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.48 * (1 + (-0.301/100) * (-10 - 25)) = 42.53 V | OCPD = 1.56 * 9.26 = 14.45 A
Inputs from CEC Modules.csv for JA Solar JAP6-60-275/4BB: Voc=38.48 V, beta_Voc=-0.301%/C, Isc=9.26 A, STC=275.0 W, Area=1.635 m2.
Result: 14 panels max on 600 V (595.4 V); 30 panels for 8 kW (528 sq ft).
What Are the Published CEC Specifications for JA Solar JAP6-60-275/4BB?
Complete CEC test sheet for JA Solar JAP6-60-275/4BB including Isc (9.26 A), Voc (38.48 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 275.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 254.9 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.48 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.26 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.44 V / 8.75 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.301 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.82% (1.635 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many JA Solar JAP6-60-275/4BB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using JA Solar JAP6-60-275/4BB.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.05 kW | 387 sq ft | $1,514 | $2,561 |
| 8 kW Class | 30 | 8.25 kW | 528 sq ft | $2,065 | $3,492 |
| 10 kW Class | 37 | 10.18 kW | 651 sq ft | $2,548 | $4,308 |
How Many JA Solar JAP6-60-275/4BB Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for JA Solar JAP6-60-275/4BB (38.48 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.69 V | 13 panels | 568.0 V | 22 panels |
| -10 C (14 F) | 42.53 V | 14 panels | 595.4 V | 23 panels |
| 0 C (32 F) | 41.38 V | 14 panels | 579.3 V | 24 panels |
| 25 C (77 F STC) | 38.48 V | 15 panels | 577.2 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-60-275/4BB?
Four comparable CEC modules such as AXITEC AC-275P/60S (275.0 W) for side-by-side solar quote checks. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-275P/60S AXITEC |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 92.2% |
| AXITEC AC-275P/60V AXITEC |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 92.2% |
| GCL System Integration Technology Co Ltd GCL-M6/60275 GCL System Integration Technology Co Ltd |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 90.0% |
| GCL System Integration Technology Co Ltd GCL-P6/60275 GCL System Integration Technology Co Ltd |
275.0 W | Tie (0 W) | 38.5 V | 16.9% | 90.7% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-60-275/4BB?
Evaluate JA Solar JAP6-60-275/4BB (275.0 W STC, 38.48 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-60-275/4BB reaches 43.69 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 528 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (528 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6-60-275/4BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAP6-60-275/4BB 8 kW Residential Fit
Needs 30 modules (528 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-275P/60S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 254.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAP6-60-275/4BB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is JA Solar JAP6-60-275/4BB PTC wattage (254.9 W) lower than STC (275.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 254.9 W PTC (92.7% retention) across JA Solar JAP6-60-275/4BB's 1.635 m2 aperture.
Who should skip JA Solar JAP6-60-275/4BB on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 30 JA Solar JAP6-60-275/4BB panels (528 sq ft) leave unusable roof gaps vs. AXITEC AC-275P/60S.
What is the 1,000 V commercial string limit for JA Solar JAP6-60-275/4BB?
On 1,000 V commercial inverters at -10 C (42.53 V cold Voc), JA Solar JAP6-60-275/4BB fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting JA Solar JAP6-60-275/4BB.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)