JA Solar JAP6-60-275/3BB is a 275.0 W STC (248.7 W PTC) Multi-c-Si solar module ranking #18,259 of 21,677 CEC listings (below all-CEC median; higher than 14.3% of peers). It delivers 16.82% efficiency, 38.46 V Voc at 25 C, and 42.63 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 275.0 W
- PTC Wattage
- 248.7 W
- Voc @ 25C
- 38.46 V
- Efficiency
- 16.82%
How Does JA Solar JAP6-60-275/3BB Compare Against Peer CEC Listings?
How JA Solar JA Solar JAP6-60-275/3BB handles rooftop heat (248.7 W PTC), 8 kW sizing, and cold winter string voltage.
JA Solar builds the JA Solar JAP6-60-275/3BB (Multi-c-Si) as a compact residential or specialty off-grid module delivering 168.2 W/m2 (3.09 percentage points below 19.91% CEC median). Compared against AXITEC AC-275P/60S (275.0 W), this model holds typical 90.4% PTC-to-STC thermal output (248.7 W real-world rating). Lower 38.46 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.38 A overcurrent floor served by a 15 A breaker.
Where Does JA Solar JAP6-60-275/3BB Fall Across Listed CEC Models?
Where JA Solar JAP6-60-275/3BB (275.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define JA Solar JAP6-60-275/3BB?
Percentile placement of JA Solar JAP6-60-275/3BB across power density (168.2 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for JA Solar JAP6-60-275/3BB?
Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAP6-60-275/3BB specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
275.0 W STC · Higher Than 14.3%
275.0 W STC (-110.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.82% Aperture Efficiency
Power density 168.2 W/m2 (3.09 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.63 V at -10 C (596.8 V string) and 43.83 V at -20 C (13 max).
30 Panels = 8,250 W STC
Occupies 49.0 m2 (528 sq ft) producing 7,461 W PTC; NEC 690.8 OCPD floor is 14.38 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.46 * (1 + (-0.31/100) * (-10 - 25)) = 42.63 V | OCPD = 1.56 * 9.22 = 14.38 A
Inputs from CEC Modules.csv for JA Solar JAP6-60-275/3BB: Voc=38.46 V, beta_Voc=-0.31%/C, Isc=9.22 A, STC=275.0 W, Area=1.635 m2.
Result: 14 panels max on 600 V (596.8 V); 30 panels for 8 kW (528 sq ft).
What Are the Published CEC Specifications for JA Solar JAP6-60-275/3BB?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAP6-60-275/3BB.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 275.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 248.7 W (90.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.46 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.22 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.61 V / 8.7 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.31 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.82% (1.635 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many JA Solar JAP6-60-275/3BB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAP6-60-275/3BB (275.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.05 kW | 387 sq ft | $1,514 | $2,561 |
| 8 kW Class | 30 | 8.25 kW | 528 sq ft | $2,065 | $3,492 |
| 10 kW Class | 37 | 10.18 kW | 651 sq ft | $2,548 | $4,308 |
How Many JA Solar JAP6-60-275/3BB Modules Fit in a Cold-Weather String?
Maximum series module counts for JA Solar JAP6-60-275/3BB from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.83 V | 13 panels | 569.8 V | 22 panels |
| -10 C (14 F) | 42.63 V | 14 panels | 596.8 V | 23 panels |
| 0 C (32 F) | 41.44 V | 14 panels | 580.2 V | 24 panels |
| 25 C (77 F STC) | 38.46 V | 15 panels | 576.9 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-60-275/3BB?
Alternative CEC solar modules from competing brands near JA Solar JAP6-60-275/3BB (275.0 W), including AXITEC AC-275P/60S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-275P/60S AXITEC |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 92.2% |
| AXITEC AC-275P/60V AXITEC |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 92.2% |
| GCL System Integration Technology Co Ltd GCL-M6/60275 GCL System Integration Technology Co Ltd |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 90.0% |
| GCL System Integration Technology Co Ltd GCL-P6/60275 GCL System Integration Technology Co Ltd |
275.0 W | Tie (0 W) | 38.5 V | 16.9% | 90.7% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-60-275/3BB?
Evaluate JA Solar JAP6-60-275/3BB (275.0 W STC, 38.46 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-60-275/3BB reaches 43.83 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 528 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (528 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAP6-60-275/3BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAP6-60-275/3BB 8 kW Residential Fit
Needs 30 modules (528 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-275P/60S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 248.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAP6-60-275/3BB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for JA Solar JAP6-60-275/3BB?
Multiplying JA Solar JAP6-60-275/3BB's 9.22 A short-circuit current by 1.56 equals 14.38 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can JA Solar JAP6-60-275/3BB pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 42.63 V cold Voc at 14 F and handles 9.22 A Isc; string inverters cap JA Solar JAP6-60-275/3BB at 14 panels on 600 V.
Is JA Solar JAP6-60-275/3BB eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAP6-60-275/3BB rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)