Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAP6-60-275/3BB is a 275.0 W STC (248.7 W PTC) Multi-c-Si solar module ranking #18,259 of 21,677 CEC listings (below all-CEC median; higher than 14.3% of peers). It delivers 16.82% efficiency, 38.46 V Voc at 25 C, and 42.63 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
275.0 W
PTC Wattage
248.7 W
Voc @ 25C
38.46 V
Efficiency
16.82%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAP6-60-275/3BB Compare Against Peer CEC Listings?

How JA Solar JA Solar JAP6-60-275/3BB handles rooftop heat (248.7 W PTC), 8 kW sizing, and cold winter string voltage.

JA Solar builds the JA Solar JAP6-60-275/3BB (Multi-c-Si) as a compact residential or specialty off-grid module delivering 168.2 W/m2 (3.09 percentage points below 19.91% CEC median). Compared against AXITEC AC-275P/60S (275.0 W), this model holds typical 90.4% PTC-to-STC thermal output (248.7 W real-world rating). Lower 38.46 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.38 A overcurrent floor served by a 15 A breaker.

Where Does JA Solar JAP6-60-275/3BB Fall Across Listed CEC Models?

Where JA Solar JAP6-60-275/3BB (275.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAP6-60-275/3BB (275.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAP6-60-2: 275.0 W

What Dataset Percentiles Define JA Solar JAP6-60-275/3BB?

Percentile placement of JA Solar JAP6-60-275/3BB across power density (168.2 W/m2), thermal retention, and nameplate STC wattage.

JA Solar JAP6-60-275/3BB Engineering BenchmarksPercentile comparison of JA Solar JAP6-60-275/3BB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage275.0 WPTC/STC Retention90.4%Module Efficiency16.82%

What Do the Dataset Ranks Show for JA Solar JAP6-60-275/3BB?

Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAP6-60-275/3BB specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #18,259 / 21,677

275.0 W STC · Higher Than 14.3%

275.0 W STC (-110.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,751

16.82% Aperture Efficiency

Power density 168.2 W/m2 (3.09 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.63 V at -10 C (596.8 V string) and 43.83 V at -20 C (13 max).

8 kW Reference Array

30 Panels = 8,250 W STC

Occupies 49.0 m2 (528 sq ft) producing 7,461 W PTC; NEC 690.8 OCPD floor is 14.38 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.46 * (1 + (-0.31/100) * (-10 - 25)) = 42.63 V | OCPD = 1.56 * 9.22 = 14.38 A

Inputs from CEC Modules.csv for JA Solar JAP6-60-275/3BB: Voc=38.46 V, beta_Voc=-0.31%/C, Isc=9.22 A, STC=275.0 W, Area=1.635 m2.

Result: 14 panels max on 600 V (596.8 V); 30 panels for 8 kW (528 sq ft).

What Are the Published CEC Specifications for JA Solar JAP6-60-275/3BB?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAP6-60-275/3BB.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAP6-60-275/3BB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 275.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 248.7 W (90.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.46 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.22 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.61 V / 8.7 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.31 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.82% (1.635 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many JA Solar JAP6-60-275/3BB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAP6-60-275/3BB (275.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.05 kW 387 sq ft $1,514 $2,561
8 kW Class 30 8.25 kW 528 sq ft $2,065 $3,492
10 kW Class 37 10.18 kW 651 sq ft $2,548 $4,308

How Many JA Solar JAP6-60-275/3BB Modules Fit in a Cold-Weather String?

Maximum series module counts for JA Solar JAP6-60-275/3BB from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=38.46V and beta_Voc=-0.31%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.83 V 13 panels 569.8 V 22 panels
-10 C (14 F) 42.63 V 14 panels 596.8 V 23 panels
0 C (32 F) 41.44 V 14 panels 580.2 V 24 panels
25 C (77 F STC) 38.46 V 15 panels 576.9 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAP6-60-275/3BB?

Alternative CEC solar modules from competing brands near JA Solar JAP6-60-275/3BB (275.0 W), including AXITEC AC-275P/60S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-275P/60S
AXITEC
275.0 W Tie (0 W) 38.5 V 16.87% 92.2%
AXITEC AC-275P/60V
AXITEC
275.0 W Tie (0 W) 38.5 V 16.87% 92.2%
GCL System Integration Technology Co Ltd GCL-M6/60275
GCL System Integration Technology Co Ltd
275.0 W Tie (0 W) 38.5 V 16.87% 90.0%
GCL System Integration Technology Co Ltd GCL-P6/60275
GCL System Integration Technology Co Ltd
275.0 W Tie (0 W) 38.5 V 16.9% 90.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAP6-60-275/3BB?

Evaluate JA Solar JAP6-60-275/3BB (275.0 W STC, 38.46 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAP6-60-275/3BB reaches 43.83 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 528 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (528 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAP6-60-275/3BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAP6-60-275/3BB 8 kW Residential Fit

Needs 30 modules (528 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-275P/60S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 248.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAP6-60-275/3BB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for JA Solar JAP6-60-275/3BB?

Multiplying JA Solar JAP6-60-275/3BB's 9.22 A short-circuit current by 1.56 equals 14.38 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can JA Solar JAP6-60-275/3BB pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.63 V cold Voc at 14 F and handles 9.22 A Isc; string inverters cap JA Solar JAP6-60-275/3BB at 14 panels on 600 V.

Is JA Solar JAP6-60-275/3BB eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAP6-60-275/3BB rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.