Hansol Technics Co Ltd HS275NB-AN4 is a 275.0 W STC (252.3 W PTC) Multi-c-Si solar module ranking #18,259 of 21,677 CEC listings (below all-CEC median; higher than 14.3% of peers). It delivers 17.01% efficiency, 38.8 V Voc at 25 C, and 42.93 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 275.0 W
- PTC Wattage
- 252.3 W
- Voc @ 25C
- 38.8 V
- Efficiency
- 17.01%
How Does Hansol Technics Co Ltd HS275NB-AN4 Compare Against Peer CEC Listings?
How Hansol Technics Co Ltd Hansol Technics Co Ltd HS275NB-AN4 handles rooftop heat (252.3 W PTC), 8 kW sizing, and cold winter string voltage.
Hansol Technics Co Ltd builds the Hansol Technics Co Ltd HS275NB-AN4 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 170.1 W/m2 (2.90 percentage points below 19.91% CEC median). Compared against Flextronics FXS-275BB-SAC1B (275.0 W), this model holds strong 91.7% PTC-to-STC heat retention (#15,053 of 21,677). Lower 38.8 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.37 A overcurrent floor served by a 15 A breaker.
Where Does Hansol Technics Co Ltd HS275NB-AN4 Fall Across Listed CEC Models?
Where Hansol Technics Co Ltd HS275NB-AN4 (275.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Hansol Technics Co Ltd HS275NB-AN4?
Percentile placement of Hansol Technics Co Ltd HS275NB-AN4 across power density (170.1 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS275NB-AN4?
Four critical engineering numbers homeowners and solar installers check first when reviewing Hansol Technics Co Ltd HS275NB-AN4 specifications.
275.0 W STC · Higher Than 14.3%
275.0 W STC (-110.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
17.01% Aperture Efficiency
Power density 170.1 W/m2 (2.90 percentage points below 19.91% CEC median). PTC/STC ratio: 91.7% (rank #15,053).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.93 V at -10 C (558.1 V string) and 44.11 V at -20 C (13 max).
30 Panels = 8,250 W STC
Occupies 48.5 m2 (522 sq ft) producing 7,569 W PTC; NEC 690.8 OCPD floor is 14.37 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.8 * (1 + (-0.304/100) * (-10 - 25)) = 42.93 V | OCPD = 1.56 * 9.21 = 14.37 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS275NB-AN4: Voc=38.8 V, beta_Voc=-0.304%/C, Isc=9.21 A, STC=275.0 W, Area=1.617 m2.
Result: 13 panels max on 600 V (558.1 V); 30 panels for 8 kW (522 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS275NB-AN4?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hansol Technics Co Ltd HS275NB-AN4.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 275.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 252.3 W (91.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.21 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.7 V / 8.68 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.304 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.01% (1.617 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS275NB-AN4 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hansol Technics Co Ltd HS275NB-AN4 (275.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.05 kW | 383 sq ft | $1,514 | $2,561 |
| 8 kW Class | 30 | 8.25 kW | 522 sq ft | $2,065 | $3,492 |
| 10 kW Class | 37 | 10.18 kW | 644 sq ft | $2,548 | $4,308 |
How Many Hansol Technics Co Ltd HS275NB-AN4 Modules Fit in a Cold-Weather String?
Maximum series module counts for Hansol Technics Co Ltd HS275NB-AN4 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.11 V | 13 panels | 573.4 V | 22 panels |
| -10 C (14 F) | 42.93 V | 13 panels | 558.1 V | 23 panels |
| 0 C (32 F) | 41.75 V | 14 panels | 584.5 V | 23 panels |
| 25 C (77 F STC) | 38.8 V | 15 panels | 582.0 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS275NB-AN4?
Alternative CEC solar modules from competing brands near Hansol Technics Co Ltd HS275NB-AN4 (275.0 W), including Flextronics FXS-275BB-SAC1B.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Flextronics FXS-275BB-SAC1B Flextronics |
275.0 W | Tie (0 W) | 38.6 V | 16.75% | 91.4% |
| AXITEC AC-275P/60S AXITEC |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 92.2% |
| AXITEC AC-275P/60V AXITEC |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 92.2% |
| GCL System Integration Technology Co Ltd GCL-M6/60275 GCL System Integration Technology Co Ltd |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 90.0% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS275NB-AN4?
Evaluate Hansol Technics Co Ltd HS275NB-AN4 (275.0 W STC, 38.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS275NB-AN4 reaches 44.11 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 522 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (522 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS275NB-AN4 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS275NB-AN4 8 kW Residential Fit
Needs 30 modules (522 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Flextronics FXS-275BB-SAC1B.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 252.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS275NB-AN4 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HS275NB-AN4?
Multiplying Hansol Technics Co Ltd HS275NB-AN4's 9.21 A short-circuit current by 1.56 equals 14.37 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Hansol Technics Co Ltd HS275NB-AN4 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 42.93 V cold Voc at 14 F and handles 9.21 A Isc; string inverters cap Hansol Technics Co Ltd HS275NB-AN4 at 13 panels on 600 V.
Is Hansol Technics Co Ltd HS275NB-AN4 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HS275NB-AN4 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)