Hansol Technics Co Ltd HS260NB-AN3 is a 260.0 W STC (238.2 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 15.57% efficiency, 37.6 V Voc at 25 C, and 41.55 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 260.0 W
- PTC Wattage
- 238.2 W
- Voc @ 25C
- 37.6 V
- Efficiency
- 15.57%
How Does Hansol Technics Co Ltd HS260NB-AN3 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hansol Technics Co Ltd HS260NB-AN3 (Multi-c-Si) residential solar systems.
Homeowners evaluating Hansol Technics Co Ltd HS260NB-AN3 need 24 panels for 6 kW or 31 panels (557 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (557 sq ft). Under NEC 690.7(A), beta_Voc (-0.3%/C) pushes open-circuit voltage to 41.55 V at 14 F and 42.68 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Hansol Technics Co Ltd HS260NB-AN3 Fall Across Listed CEC Models?
Comparison of Hansol Technics Co Ltd HS260NB-AN3 (260.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Hansol Technics Co Ltd HS260NB-AN3?
Relative ranking of Hansol Technics Co Ltd HS260NB-AN3 across nameplate watts, 91.6% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS260NB-AN3?
Summary of Hansol Technics Co Ltd HS260NB-AN3 output rank, 8 kW array size (31 panels), efficiency rating, and 600 V string limit.
260.0 W STC · Higher Than 10.4%
260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.57% Aperture Efficiency
Power density 155.7 W/m2 (4.34 percentage points below 19.91% CEC median). PTC/STC ratio: 91.6% (rank #15,328).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.55 V at -10 C (581.7 V string) and 42.68 V at -20 C (14 max).
31 Panels = 8,060 W STC
Occupies 51.8 m2 (557 sq ft) producing 7,384 W PTC; NEC 690.8 OCPD floor is 14.15 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.6 * (1 + (-0.3/100) * (-10 - 25)) = 41.55 V | OCPD = 1.56 * 9.07 = 14.15 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS260NB-AN3: Voc=37.6 V, beta_Voc=-0.3%/C, Isc=9.07 A, STC=260.0 W, Area=1.67 m2.
Result: 14 panels max on 600 V (581.7 V); 31 panels for 8 kW (557 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS260NB-AN3?
Complete CEC test sheet for Hansol Technics Co Ltd HS260NB-AN3 including Isc (9.07 A), Voc (37.6 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 238.2 W (91.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.07 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.5 V / 8.54 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.3 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.57% (1.67 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS260NB-AN3 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hansol Technics Co Ltd HS260NB-AN3.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.24 kW | 431 sq ft | $1,562 | $2,641 |
| 8 kW Class | 31 | 8.06 kW | 557 sq ft | $2,017 | $3,411 |
| 10 kW Class | 39 | 10.14 kW | 701 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?
Related Hansol Technics Co Ltd power steps and black/silver trims consolidated into this Hansol Technics Co Ltd HS260NB-AN3 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HS250NB-AN3 | 250.0 W | 228.9 W | 36.8 V | 29.7 V | 14.97% |
| Hansol Technics Co Ltd HS255NB-AN3 | 255.0 W | 233.6 W | 37.2 V | 30.1 V | 15.27% |
| Hansol Technics Co Ltd HS260NB-AN3 | 260.0 W | 238.2 W | 37.6 V | 30.5 V | 15.57% |
| Hansol Technics Co Ltd HS265NB-AN3 | 265.0 W | 242.9 W | 38.0 V | 30.9 V | 15.87% |
| Hansol Technics Co Ltd HS270NB-AN3 | 270.0 W | 247.6 W | 38.4 V | 31.3 V | 16.17% |
How Many Hansol Technics Co Ltd HS260NB-AN3 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Hansol Technics Co Ltd HS260NB-AN3 (37.6 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.68 V | 14 panels | 597.5 V | 23 panels |
| -10 C (14 F) | 41.55 V | 14 panels | 581.7 V | 24 panels |
| 0 C (32 F) | 40.42 V | 14 panels | 565.9 V | 24 panels |
| 25 C (77 F STC) | 37.6 V | 15 panels | 564.0 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS260NB-AN3?
Four comparable CEC modules such as Anhui Rinengzhongtian Semiconductor Development QJP260-60 (260.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Anhui Rinengzhongtian Semiconductor Development QJP260-60 Anhui Rinengzhongtian Semiconductor Development |
260.0 W | Tie (0 W) | 37.64 V | 15.98% | 90.7% |
| AXITEC AC-260P/156-60S AXITEC |
260.0 W | Tie (0 W) | 37.65 V | 16.02% | 89.0% |
| Centrosolar America EP6 260BW Centrosolar America |
260.0 W | Tie (0 W) | 37.65 V | 16.02% | 89.0% |
| Centrosolar America EP6 260SW Centrosolar America |
260.0 W | Tie (0 W) | 37.65 V | 16.02% | 89.0% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS260NB-AN3?
Evaluate Hansol Technics Co Ltd HS260NB-AN3 (260.0 W STC, 37.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS260NB-AN3 reaches 42.68 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 557 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (557 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS260NB-AN3 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS260NB-AN3 8 kW Residential Fit
Needs 31 modules (557 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJP260-60.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 238.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS260NB-AN3 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Hansol Technics Co Ltd HS260NB-AN3 PTC wattage (238.2 W) lower than STC (260.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 238.2 W PTC (91.6% retention) across Hansol Technics Co Ltd HS260NB-AN3's 1.67 m2 aperture.
Who should skip Hansol Technics Co Ltd HS260NB-AN3 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 31 Hansol Technics Co Ltd HS260NB-AN3 panels (557 sq ft) leave unusable roof gaps vs. Anhui Rinengzhongtian Semiconductor Development QJP260-60.
What is the 1,000 V commercial string limit for Hansol Technics Co Ltd HS260NB-AN3?
On 1,000 V commercial inverters at -10 C (41.55 V cold Voc), Hansol Technics Co Ltd HS260NB-AN3 fits up to 24 panels per series string.