Skip to main content
WireAndSun
Calculators
CEC PV Module

Centrosolar America EP6 260BW — CEC Solar Module Specifications

Manufacturer: Centrosolar America Registry: CEC Verified Engineering Specification

Centrosolar America EP6 260BW is a 260.0 W STC (231.5 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 16.02% efficiency, 37.65 V Voc at 25 C, and 42.13 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
260.0 W
PTC Wattage
231.5 W
Voc @ 25C
37.65 V
Efficiency
16.02%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Centrosolar America EP6 260BW Compare Against Peer CEC Listings?

How Centrosolar America Centrosolar America EP6 260BW handles rooftop heat (231.5 W PTC), 8 kW sizing, and cold winter string voltage.

Centrosolar America builds the Centrosolar America EP6 260BW (Multi-c-Si) as a compact residential or specialty off-grid module delivering 160.2 W/m2 (3.89 percentage points below 19.91% CEC median). Compared against AXITEC AC-260P/156-60S (260.0 W), this model holds typical 89.0% PTC-to-STC thermal output (231.5 W real-world rating). Lower 37.65 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 14.18 A overcurrent floor served by a 15 A breaker.

Where Does Centrosolar America EP6 260BW Fall Across Listed CEC Models?

Where Centrosolar America EP6 260BW (260.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Centrosolar America EP6 260BW (260.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCentrosolar Americ: 260.0 W

What Dataset Percentiles Define Centrosolar America EP6 260BW?

Percentile placement of Centrosolar America EP6 260BW across power density (160.2 W/m2), thermal retention, and nameplate STC wattage.

Centrosolar America EP6 260BW Engineering BenchmarksPercentile comparison of Centrosolar America EP6 260BW wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage260.0 WPTC/STC Retention89.0%Module Efficiency16.02%

What Do the Dataset Ranks Show for Centrosolar America EP6 260BW?

Four critical engineering numbers homeowners and solar installers check first when reviewing Centrosolar America EP6 260BW specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #19,146 / 21,677

260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,108

16.02% Aperture Efficiency

Power density 160.2 W/m2 (3.89 percentage points below 19.91% CEC median). PTC/STC ratio: 89.0% (rank #20,637).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.13 V at -10 C (589.8 V string) and 43.41 V at -20 C (13 max).

8 kW Reference Array

31 Panels = 8,060 W STC

Occupies 50.3 m2 (542 sq ft) producing 7,176 W PTC; NEC 690.8 OCPD floor is 14.18 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.65 * (1 + (-0.34/100) * (-10 - 25)) = 42.13 V | OCPD = 1.56 * 9.09 = 14.18 A

Inputs from CEC Modules.csv for Centrosolar America EP6 260BW: Voc=37.65 V, beta_Voc=-0.34%/C, Isc=9.09 A, STC=260.0 W, Area=1.623 m2.

Result: 14 panels max on 600 V (589.8 V); 31 panels for 8 kW (542 sq ft).

What Are the Published CEC Specifications for Centrosolar America EP6 260BW?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Centrosolar America EP6 260BW.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America EP6 260BW.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 260.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 231.5 W (89.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.65 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.09 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.51 V / 8.52 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.34 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.02% (1.623 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Centrosolar America EP6 260BW Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Centrosolar America EP6 260BW (260.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.24 kW 419 sq ft $1,562 $2,641
8 kW Class 31 8.06 kW 542 sq ft $2,017 $3,411
10 kW Class 39 10.14 kW 681 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?

All closely matched Centrosolar America wattages and cosmetic trims sharing the Centrosolar America EP6 260BW architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the Centrosolar America EP6 260BW wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Centrosolar America EP6 250BW 250.0 W 222.3 W 37.41 V 29.98 V 15.4%
Centrosolar America EP6 255BW 255.0 W 226.9 W 37.54 V 30.25 V 15.71%
Centrosolar America EP6 260BW 260.0 W 231.5 W 37.65 V 30.51 V 16.02%
Centrosolar America EP6 265BW 265.0 W 236.1 W 37.77 V 30.78 V 16.33%

How Many Centrosolar America EP6 260BW Modules Fit in a Cold-Weather String?

Maximum series module counts for Centrosolar America EP6 260BW from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.65V and beta_Voc=-0.34%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.41 V 13 panels 564.3 V 23 panels
-10 C (14 F) 42.13 V 14 panels 589.8 V 23 panels
0 C (32 F) 40.85 V 14 panels 571.9 V 24 panels
25 C (77 F STC) 37.65 V 15 panels 564.8 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Centrosolar America EP6 260BW?

Alternative CEC solar modules from competing brands near Centrosolar America EP6 260BW (260.0 W), including AXITEC AC-260P/156-60S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-260P/156-60S
AXITEC
260.0 W Tie (0 W) 37.65 V 16.02% 89.0%
Anhui Rinengzhongtian Semiconductor Development QJP260-60
Anhui Rinengzhongtian Semiconductor Development
260.0 W Tie (0 W) 37.64 V 15.98% 90.7%
AXITEC AC-260M/156-60S
AXITEC
260.0 W Tie (0 W) 37.73 V 16.02% 90.2%
Gintung Energy ASEC-260G6M6A
Gintung Energy
260.0 W Tie (0 W) 37.78 V 16.14% 88.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Centrosolar America EP6 260BW?

Evaluate Centrosolar America EP6 260BW (260.0 W STC, 37.65 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America EP6 260BW reaches 43.41 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 542 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (542 sq ft).
  • 2026 tax credit baseline: cash residential installs of Centrosolar America EP6 260BW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Centrosolar America EP6 260BW 8 kW Residential Fit

Needs 31 modules (542 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-260P/156-60S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 231.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America EP6 260BW by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Centrosolar America EP6 260BW?

Multiplying Centrosolar America EP6 260BW's 9.09 A short-circuit current by 1.56 equals 14.18 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Centrosolar America EP6 260BW pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.13 V cold Voc at 14 F and handles 9.09 A Isc; string inverters cap Centrosolar America EP6 260BW at 14 panels on 600 V.

Is Centrosolar America EP6 260BW eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Centrosolar America EP6 260BW rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.