Anhui Rinengzhongtian Semiconductor Development QJP260-60 is a 260.0 W STC (235.7 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 15.98% efficiency, 37.64 V Voc at 25 C, and 41.99 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 260.0 W
- PTC Wattage
- 235.7 W
- Voc @ 25C
- 37.64 V
- Efficiency
- 15.98%
How Does Anhui Rinengzhongtian Semiconductor Development QJP260-60 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Anhui Rinengzhongtian Semiconductor Development QJP260-60 (Multi-c-Si) residential solar systems.
Anhui Rinengzhongtian Semiconductor Development QJP260-60 delivers 159.8 W/m2 (3.93 percentage points below 19.91% CEC median) and typical 90.7% PTC-to-STC thermal output (235.7 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (543 sq ft). At -4 F (-20 C), string voltage climbs to 43.23 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with AXITEC AC-260P/156-60S (260.0 W).
Where Does Anhui Rinengzhongtian Semiconductor Development QJP260-60 Fall Across Listed CEC Models?
Comparison of Anhui Rinengzhongtian Semiconductor Development QJP260-60 (260.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Anhui Rinengzhongtian Semiconductor Development QJP260-60?
Relative ranking of Anhui Rinengzhongtian Semiconductor Development QJP260-60 across nameplate watts, 90.7% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Anhui Rinengzhongtian Semiconductor Development QJP260-60?
Summary of Anhui Rinengzhongtian Semiconductor Development QJP260-60 output rank, 8 kW array size (31 panels), efficiency rating, and 600 V string limit.
260.0 W STC · Higher Than 10.4%
260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.98% Aperture Efficiency
Power density 159.8 W/m2 (3.93 percentage points below 19.91% CEC median). PTC/STC ratio: 90.7% (rank #17,330).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.99 V at -10 C (587.9 V string) and 43.23 V at -20 C (13 max).
31 Panels = 8,060 W STC
Occupies 50.4 m2 (543 sq ft) producing 7,307 W PTC; NEC 690.8 OCPD floor is 14.18 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.64 * (1 + (-0.33/100) * (-10 - 25)) = 41.99 V | OCPD = 1.56 * 9.09 = 14.18 A
Inputs from CEC Modules.csv for Anhui Rinengzhongtian Semiconductor Development QJP260-60: Voc=37.64 V, beta_Voc=-0.33%/C, Isc=9.09 A, STC=260.0 W, Area=1.627 m2.
Result: 14 panels max on 600 V (587.9 V); 31 panels for 8 kW (543 sq ft).
What Are the Published CEC Specifications for Anhui Rinengzhongtian Semiconductor Development QJP260-60?
Complete CEC test sheet for Anhui Rinengzhongtian Semiconductor Development QJP260-60 including Isc (9.09 A), Voc (37.64 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 260.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 235.7 W (90.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.64 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.09 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.6 V / 8.5 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.33 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.98% (1.627 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Anhui Rinengzhongtian Semiconductor Development QJP260-60 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Anhui Rinengzhongtian Semiconductor Development QJP260-60.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.24 kW | 420 sq ft | $1,562 | $2,641 |
| 8 kW Class | 31 | 8.06 kW | 543 sq ft | $2,017 | $3,411 |
| 10 kW Class | 39 | 10.14 kW | 683 sq ft | $2,538 | $4,292 |
Which Sibling Wattage & Trim Variants Belong to This Anhui Rinengzhongtian Semiconductor Development Series?
Related Anhui Rinengzhongtian Semiconductor Development power steps and black/silver trims consolidated into this Anhui Rinengzhongtian Semiconductor Development QJP260-60 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Anhui Rinengzhongtian Semiconductor Development QJP250-60 | 250.0 W | 223.6 W | 36.5 V | 30.4 V | 15.37% |
| Anhui Rinengzhongtian Semiconductor Development QJP255-60 | 255.0 W | 231.0 W | 37.52 V | 30.5 V | 15.67% |
| Anhui Rinengzhongtian Semiconductor Development QJP260-60 | 260.0 W | 235.7 W | 37.64 V | 30.6 V | 15.98% |
| Anhui Rinengzhongtian Semiconductor Development QJP265-60 | 265.0 W | 240.4 W | 37.76 V | 30.7 V | 16.29% |
| Anhui Rinengzhongtian Semiconductor Development QJP270-60 | 270.0 W | 245.0 W | 37.88 V | 30.8 V | 16.6% |
How Many Anhui Rinengzhongtian Semiconductor Development QJP260-60 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Anhui Rinengzhongtian Semiconductor Development QJP260-60 (37.64 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.23 V | 13 panels | 562.0 V | 23 panels |
| -10 C (14 F) | 41.99 V | 14 panels | 587.9 V | 23 panels |
| 0 C (32 F) | 40.75 V | 14 panels | 570.5 V | 24 panels |
| 25 C (77 F STC) | 37.64 V | 15 panels | 564.6 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Anhui Rinengzhongtian Semiconductor Development QJP260-60?
Four comparable CEC modules such as AXITEC AC-260P/156-60S (260.0 W) for side-by-side solar quote checks. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-260P/156-60S AXITEC |
260.0 W | Tie (0 W) | 37.65 V | 16.02% | 89.0% |
| Centrosolar America EP6 260BW Centrosolar America |
260.0 W | Tie (0 W) | 37.65 V | 16.02% | 89.0% |
| Centrosolar America EP6 260SW Centrosolar America |
260.0 W | Tie (0 W) | 37.65 V | 16.02% | 89.0% |
| AXITEC AC-260M/156-60S AXITEC |
260.0 W | Tie (0 W) | 37.73 V | 16.02% | 90.2% |
What Are the Design Limits and Best-Fit Uses for Anhui Rinengzhongtian Semiconductor Development QJP260-60?
Evaluate Anhui Rinengzhongtian Semiconductor Development QJP260-60 (260.0 W STC, 37.64 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Anhui Rinengzhongtian Semiconductor Development QJP260-60 reaches 43.23 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 31 panels for an 8 kW build require 543 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (543 sq ft).
- 2026 tax credit baseline: cash residential installs of Anhui Rinengzhongtian Semiconductor Development QJP260-60 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Anhui Rinengzhongtian Semiconductor Development QJP260-60 8 kW Residential Fit
Needs 31 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-260P/156-60S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 235.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Anhui Rinengzhongtian Semiconductor Development QJP260-60 by Anhui Rinengzhongtian Semiconductor Development grounded in CEC test data and NEC 690.7/690.8 limits.
How many Anhui Rinengzhongtian Semiconductor Development QJP260-60 panels fit on a 600 V winter solar string?
At -10 C (14 F), Anhui Rinengzhongtian Semiconductor Development QJP260-60 cold Voc rises from 37.64 V to 41.99 V (beta_Voc -0.33%/C), capping a 600 V string at 14 panels (587.9 V).
How much roof area does an 8 kW array of Anhui Rinengzhongtian Semiconductor Development QJP260-60 need?
An 8 kW DC system uses 31 Anhui Rinengzhongtian Semiconductor Development QJP260-60 modules (8,060 W STC / 7,307 W PTC), covering roughly 543 sq ft and saving ~$2,017/yr at 18.54 c/kWh.
How does Anhui Rinengzhongtian Semiconductor Development QJP260-60 compare against AXITEC AC-260P/156-60S?
Anhui Rinengzhongtian Semiconductor Development QJP260-60 outputs 260.0 W STC (37.64 V Voc, rank #19,146 of 21,677), while AXITEC AC-260P/156-60S delivers 260.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)