Manufacturer: Centrosolar America Registry: CEC Verified Engineering Specification

Centrosolar America EP6 260SW is a 260.0 W STC (231.5 W PTC) Multi-c-Si solar module ranking #19,146 of 21,677 CEC listings (below all-CEC median; higher than 10.4% of peers). It delivers 16.02% efficiency, 37.65 V Voc at 25 C, and 42.13 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
260.0 W
PTC Wattage
231.5 W
Voc @ 25C
37.65 V
Efficiency
16.02%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Centrosolar America EP6 260SW Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Centrosolar America EP6 260SW (Multi-c-Si) residential solar systems.

Homeowners evaluating Centrosolar America EP6 260SW need 24 panels for 6 kW or 31 panels (542 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (542 sq ft). Under NEC 690.7(A), beta_Voc (-0.34%/C) pushes open-circuit voltage to 42.13 V at 14 F and 43.41 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Centrosolar America EP6 260SW Fall Across Listed CEC Models?

Comparison of Centrosolar America EP6 260SW (260.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Centrosolar America EP6 260SW (260.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCentrosolar Americ: 260.0 W

What Dataset Percentiles Define Centrosolar America EP6 260SW?

Relative ranking of Centrosolar America EP6 260SW across nameplate watts, 89.0% PTC thermal ratio, and module aperture efficiency.

Centrosolar America EP6 260SW Engineering BenchmarksPercentile comparison of Centrosolar America EP6 260SW wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage260.0 WPTC/STC Retention89.0%Module Efficiency16.02%

What Do the Dataset Ranks Show for Centrosolar America EP6 260SW?

Summary of Centrosolar America EP6 260SW output rank, 8 kW array size (31 panels), efficiency rating, and 600 V string limit.

Rank #19,146 / 21,677

260.0 W STC · Higher Than 10.4%

260.0 W STC (-125.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,108

16.02% Aperture Efficiency

Power density 160.2 W/m2 (3.89 percentage points below 19.91% CEC median). PTC/STC ratio: 89.0% (rank #20,637).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.13 V at -10 C (589.8 V string) and 43.41 V at -20 C (13 max).

8 kW Reference Array

31 Panels = 8,060 W STC

Occupies 50.3 m2 (542 sq ft) producing 7,176 W PTC; NEC 690.8 OCPD floor is 14.18 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.65 * (1 + (-0.34/100) * (-10 - 25)) = 42.13 V | OCPD = 1.56 * 9.09 = 14.18 A

Inputs from CEC Modules.csv for Centrosolar America EP6 260SW: Voc=37.65 V, beta_Voc=-0.34%/C, Isc=9.09 A, STC=260.0 W, Area=1.623 m2.

Result: 14 panels max on 600 V (589.8 V); 31 panels for 8 kW (542 sq ft).

What Are the Published CEC Specifications for Centrosolar America EP6 260SW?

Complete CEC test sheet for Centrosolar America EP6 260SW including Isc (9.09 A), Voc (37.65 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America EP6 260SW.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 260.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 231.5 W (89.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.65 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.09 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.51 V / 8.52 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.34 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.02% (1.623 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Centrosolar America EP6 260SW Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Centrosolar America EP6 260SW.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.24 kW 419 sq ft $1,562 $2,641
8 kW Class 31 8.06 kW 542 sq ft $2,017 $3,411
10 kW Class 39 10.14 kW 681 sq ft $2,538 $4,292

Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?

Related Centrosolar America power steps and black/silver trims consolidated into this Centrosolar America EP6 260SW series guide.

Sibling CEC listings grouped into the Centrosolar America EP6 260SW wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Centrosolar America EP6 250SW 250.0 W 222.3 W 37.41 V 29.98 V 15.4%
Centrosolar America EP6 255SW 255.0 W 226.9 W 37.54 V 30.25 V 15.71%
Centrosolar America EP6 260SW 260.0 W 231.5 W 37.65 V 30.51 V 16.02%
Centrosolar America EP6 265SW 265.0 W 236.1 W 37.77 V 30.78 V 16.33%

How Many Centrosolar America EP6 260SW Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Centrosolar America EP6 260SW (37.65 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.65V and beta_Voc=-0.34%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.41 V 13 panels 564.3 V 23 panels
-10 C (14 F) 42.13 V 14 panels 589.8 V 23 panels
0 C (32 F) 40.85 V 14 panels 571.9 V 24 panels
25 C (77 F STC) 37.65 V 15 panels 564.8 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Centrosolar America EP6 260SW?

Four comparable CEC modules such as AXITEC AC-260P/156-60S (260.0 W) for side-by-side solar quote checks. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-260P/156-60S
AXITEC
260.0 W Tie (0 W) 37.65 V 16.02% 89.0%
Anhui Rinengzhongtian Semiconductor Development QJP260-60
Anhui Rinengzhongtian Semiconductor Development
260.0 W Tie (0 W) 37.64 V 15.98% 90.7%
AXITEC AC-260M/156-60S
AXITEC
260.0 W Tie (0 W) 37.73 V 16.02% 90.2%
Gintung Energy ASEC-260G6M6A
Gintung Energy
260.0 W Tie (0 W) 37.78 V 16.14% 88.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Centrosolar America EP6 260SW?

Evaluate Centrosolar America EP6 260SW (260.0 W STC, 37.65 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America EP6 260SW reaches 43.41 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 31 panels for an 8 kW build require 542 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 31 panels (542 sq ft).
  • 2026 tax credit baseline: cash residential installs of Centrosolar America EP6 260SW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Centrosolar America EP6 260SW 8 kW Residential Fit

Needs 31 modules (542 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-260P/156-60S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 231.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America EP6 260SW by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Centrosolar America EP6 260SW PTC wattage (231.5 W) lower than STC (260.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 231.5 W PTC (89.0% retention) across Centrosolar America EP6 260SW's 1.623 m2 aperture.

Who should skip Centrosolar America EP6 260SW on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 31 Centrosolar America EP6 260SW panels (542 sq ft) leave unusable roof gaps vs. AXITEC AC-260P/156-60S.

What is the 1,000 V commercial string limit for Centrosolar America EP6 260SW?

On 1,000 V commercial inverters at -10 C (42.13 V cold Voc), Centrosolar America EP6 260SW fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Centrosolar America EP6 260SW.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.