Skip to main content
WireAndSun
Calculators
CEC PV Module

Hanersun Technology Co Ltd CP17-60HB345W — CEC Solar Module Specifications

Manufacturer: Hanersun Technology Co Ltd Registry: CEC Verified Engineering Specification

Hanersun Technology Co Ltd CP17-60HB345W is a 345.0 W STC (323.3 W PTC) Mono-c-Si solar module ranking #13,309 of 21,677 CEC listings (below all-CEC median; higher than 37.4% of peers). It delivers 18.96% efficiency, 39.8 V Voc at 25 C, and 43.85 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
345.0 W
PTC Wattage
323.3 W
Voc @ 25C
39.8 V
Efficiency
18.96%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hanersun Technology Co Ltd CP17-60HB345W Compare Against Peer CEC Listings?

How Hanersun Technology Co Ltd Hanersun Technology Co Ltd CP17-60HB345W handles rooftop heat (323.3 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Hanersun Technology Co Ltd CP17-60HB345W exhibits 11.05 A short-circuit current, requiring a 17.24 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #13,309 of 21,677 (65.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 43.7 m2 for an 8 kW system (29 panels for 10 kW). Lower 39.8 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.

Where Does Hanersun Technology Co Ltd CP17-60HB345W Fall Across Listed CEC Models?

Where Hanersun Technology Co Ltd CP17-60HB345W (345.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hanersun Technology Co Ltd CP17-60HB345W (345.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHanersun Technolog: 345.0 W

What Dataset Percentiles Define Hanersun Technology Co Ltd CP17-60HB345W?

Percentile placement of Hanersun Technology Co Ltd CP17-60HB345W across power density (189.6 W/m2), thermal retention, and nameplate STC wattage.

Hanersun Technology Co Ltd CP17-60HB345W Engineering BenchmarksPercentile comparison of Hanersun Technology Co Ltd CP17-60HB345W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage345.0 WPTC/STC Retention93.7%Module Efficiency18.96%

What Do the Dataset Ranks Show for Hanersun Technology Co Ltd CP17-60HB345W?

Four critical engineering numbers homeowners and solar installers check first when reviewing Hanersun Technology Co Ltd CP17-60HB345W specifications.

Rank #13,309 / 21,677

345.0 W STC · Higher Than 37.4%

345.0 W STC (-40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,528

18.96% Aperture Efficiency

Power density 189.6 W/m2 (0.95 percentage points below 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.85 V at -10 C (570.1 V string) and 45.01 V at -20 C (13 max).

8 kW Reference Array

24 Panels = 8,280 W STC

Occupies 43.7 m2 (470 sq ft) producing 7,759 W PTC; NEC 690.8 OCPD floor is 17.24 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.8 * (1 + (-0.291/100) * (-10 - 25)) = 43.85 V | OCPD = 1.56 * 11.05 = 17.24 A

Inputs from CEC Modules.csv for Hanersun Technology Co Ltd CP17-60HB345W: Voc=39.8 V, beta_Voc=-0.291%/C, Isc=11.05 A, STC=345.0 W, Area=1.82 m2.

Result: 13 panels max on 600 V (570.1 V); 24 panels for 8 kW (470 sq ft).

What Are the Published CEC Specifications for Hanersun Technology Co Ltd CP17-60HB345W?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hanersun Technology Co Ltd CP17-60HB345W.

Official California Energy Commission (NREL SAM) test parameters for Hanersun Technology Co Ltd CP17-60HB345W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 345.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 323.3 W (93.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.05 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.8 V / 10.53 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.291 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.96% (1.82 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Hanersun Technology Co Ltd CP17-60HB345W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hanersun Technology Co Ltd CP17-60HB345W (345.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.21 kW 353 sq ft $1,554 $2,628
8 kW Class 24 8.28 kW 470 sq ft $2,072 $3,504
10 kW Class 29 10.01 kW 568 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This Hanersun Technology Co Ltd Series?

All closely matched Hanersun Technology Co Ltd wattages and cosmetic trims sharing the Hanersun Technology Co Ltd CP17-60HB345W architecture.

Sibling CEC listings grouped into the Hanersun Technology Co Ltd CP17-60HB345W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hanersun Technology Co Ltd CP17-60HB340W 340.0 W 318.5 W 39.6 V 32.5 V 18.68%
Hanersun Technology Co Ltd CP17-60HB345W 345.0 W 323.3 W 39.8 V 32.8 V 18.96%

How Many Hanersun Technology Co Ltd CP17-60HB345W Modules Fit in a Cold-Weather String?

Maximum series module counts for Hanersun Technology Co Ltd CP17-60HB345W from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=39.8V and beta_Voc=-0.291%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.01 V 13 panels 585.1 V 22 panels
-10 C (14 F) 43.85 V 13 panels 570.1 V 22 panels
0 C (32 F) 42.7 V 14 panels 597.8 V 23 panels
25 C (77 F STC) 39.8 V 15 panels 597.0 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to Hanersun Technology Co Ltd CP17-60HB345W?

Alternative CEC solar modules from competing brands near Hanersun Technology Co Ltd CP17-60HB345W (345.0 W), including CSI Solar Co Ltd CS3L-345MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3L-345MS
CSI Solar Co Ltd
345.0 W Tie (0 W) 39.8 V 19.27% 92.9%
ELITE Solar ET-M660BH345BB
ELITE Solar
345.0 W Tie (0 W) 39.9 V 19.17% 93.5%
Caterpillar Inc PVC345MP03HA
Caterpillar Inc
345.0 W Tie (0 W) 40.2 V 19.49% 93.3%
DualSun SAS DualSun 340M-120-00
DualSun SAS
340.0 W -5.0 W 40.1 V 18.78% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hanersun Technology Co Ltd CP17-60HB345W?

Evaluate Hanersun Technology Co Ltd CP17-60HB345W (345.0 W STC, 39.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hanersun Technology Co Ltd CP17-60HB345W reaches 45.01 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 470 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (470 sq ft).
  • 2026 tax credit baseline: cash residential installs of Hanersun Technology Co Ltd CP17-60HB345W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hanersun Technology Co Ltd CP17-60HB345W 8 kW Residential Fit

Needs 24 modules (470 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS3L-345MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 323.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hanersun Technology Co Ltd CP17-60HB345W by Hanersun Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Hanersun Technology Co Ltd CP17-60HB345W PTC wattage (323.3 W) lower than STC (345.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 323.3 W PTC (93.7% retention) across Hanersun Technology Co Ltd CP17-60HB345W's 1.82 m2 aperture.

Who should skip Hanersun Technology Co Ltd CP17-60HB345W on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 24 Hanersun Technology Co Ltd CP17-60HB345W panels (470 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3L-345MS.

What is the 1,000 V commercial string limit for Hanersun Technology Co Ltd CP17-60HB345W?

On 1,000 V commercial inverters at -10 C (43.85 V cold Voc), Hanersun Technology Co Ltd CP17-60HB345W fits up to 22 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.