Manufacturer: Hanersun Technology Co Ltd Registry: CEC Verified Engineering Specification

Hanersun Technology Co Ltd CP17-72HB430W is a 430.0 W STC (403.4 W PTC) Mono-c-Si solar module ranking #7,266 of 21,677 CEC listings (top 35.2%; higher than 64.8% of peers). It delivers 19.82% efficiency, 48.8 V Voc at 25 C, and 53.77 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
430.0 W
PTC Wattage
403.4 W
Voc @ 25C
48.8 V
Efficiency
19.82%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hanersun Technology Co Ltd CP17-72HB430W Compare Against Peer CEC Listings?

Solar engineering breakdown for Hanersun Technology Co Ltd CP17-72HB430W: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 430.0 W STC and 403.4 W PTC, Hanersun Technology Co Ltd CP17-72HB430W sits +45.0 W vs all-CEC median (top 35.2%; higher than 64.8% of peers) among 21,677 listed modules. Power density reaches 198.2 W/m2 (0.09 percentage points below 19.91% CEC median). Higher 48.8 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Caterpillar Inc PVC435MP03H rates 435.0 W.

Where Does Hanersun Technology Co Ltd CP17-72HB430W Fall Across Listed CEC Models?

Distribution marker showing Hanersun Technology Co Ltd CP17-72HB430W (430.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hanersun Technology Co Ltd CP17-72HB430W (430.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHanersun Technolog: 430.0 W

What Dataset Percentiles Define Hanersun Technology Co Ltd CP17-72HB430W?

Dataset percentiles tracking Hanersun Technology Co Ltd CP17-72HB430W power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Hanersun Technology Co Ltd CP17-72HB430W Engineering BenchmarksPercentile comparison of Hanersun Technology Co Ltd CP17-72HB430W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage430.0 WPTC/STC Retention93.8%Module Efficiency19.82%

What Do the Dataset Ranks Show for Hanersun Technology Co Ltd CP17-72HB430W?

Benchmark highlights for Hanersun Technology Co Ltd CP17-72HB430W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #7,266 / 21,677

Top 35.2% STC Output

430.0 W STC (+45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,125

19.82% Aperture Efficiency

Power density 198.2 W/m2 (0.09 percentage points below 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.77 V at -10 C (591.5 V string) and 55.19 V at -20 C (10 max).

8 kW Reference Array

19 Panels = 8,170 W STC

Occupies 41.2 m2 (444 sq ft) producing 7,665 W PTC; NEC 690.8 OCPD floor is 17.53 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.8 * (1 + (-0.291/100) * (-10 - 25)) = 53.77 V | OCPD = 1.56 * 11.24 = 17.53 A

Inputs from CEC Modules.csv for Hanersun Technology Co Ltd CP17-72HB430W: Voc=48.8 V, beta_Voc=-0.291%/C, Isc=11.24 A, STC=430.0 W, Area=2.17 m2.

Result: 11 panels max on 600 V (591.5 V); 19 panels for 8 kW (444 sq ft).

What Are the Published CEC Specifications for Hanersun Technology Co Ltd CP17-72HB430W?

Official CEC datasheet figures for Hanersun Technology Co Ltd CP17-72HB430W (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Hanersun Technology Co Ltd CP17-72HB430W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 430.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 403.4 W (93.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.24 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.3 V / 10.67 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.291 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.82% (2.17 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Hanersun Technology Co Ltd CP17-72HB430W Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Hanersun Technology Co Ltd CP17-72HB430W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.02 kW 327 sq ft $1,507 $2,548
8 kW Class 19 8.17 kW 444 sq ft $2,045 $3,458
10 kW Class 24 10.32 kW 561 sq ft $2,583 $4,368

Which Sibling Wattage & Trim Variants Belong to This Hanersun Technology Co Ltd Series?

Consolidated Hanersun Technology Co Ltd wattage variants sharing the Hanersun Technology Co Ltd CP17-72HB430W mechanical and cell layout.

Sibling CEC listings grouped into the Hanersun Technology Co Ltd CP17-72HB430W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hanersun Technology Co Ltd CP17-72HB425W 425.0 W 398.6 W 48.6 V 40.1 V 19.59%
Hanersun Technology Co Ltd CP17-72HB430W 430.0 W 403.4 W 48.8 V 40.3 V 19.82%

How Many Hanersun Technology Co Ltd CP17-72HB430W Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Hanersun Technology Co Ltd CP17-72HB430W (53.77 V at 14 F).

Computed from Voc=48.8V and beta_Voc=-0.291%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.19 V 10 panels 551.9 V 18 panels
-10 C (14 F) 53.77 V 11 panels 591.5 V 18 panels
0 C (32 F) 52.35 V 11 panels 575.9 V 19 panels
25 C (77 F STC) 48.8 V 12 panels 585.6 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Hanersun Technology Co Ltd CP17-72HB430W?

Competing CEC solar panels closest to Hanersun Technology Co Ltd CP17-72HB430W in nameplate wattage and Voc, starting with Caterpillar Inc PVC435MP03H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Caterpillar Inc PVC435MP03H
Caterpillar Inc
435.0 W +5.0 W 48.7 V 20.52% 93.6%
CSI Solar Co Ltd CS3W-435P
CSI Solar Co Ltd
435.0 W +5.0 W 48.6 V 20.33% 92.4%
AXITEC AC-435MB/144V
AXITEC
435.0 W +5.0 W 49.1 V 20.33% 92.6%
Dehui Solar Power (Vietnam) CoLtd DH-M772F 435W
Dehui Solar Power (Vietnam) CoLtd
435.0 W +5.0 W 49.1 V 20.33% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hanersun Technology Co Ltd CP17-72HB430W?

Evaluate Hanersun Technology Co Ltd CP17-72HB430W (430.0 W STC, 48.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hanersun Technology Co Ltd CP17-72HB430W reaches 55.19 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 444 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (444 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Hanersun Technology Co Ltd CP17-72HB430W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hanersun Technology Co Ltd CP17-72HB430W 8 kW Residential Fit

Needs 19 modules (444 sq ft) with a 20 A string OCPD, offsetting ~$2,045/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Caterpillar Inc PVC435MP03H.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 403.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hanersun Technology Co Ltd CP17-72HB430W by Hanersun Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many Hanersun Technology Co Ltd CP17-72HB430W panels fit on a 600 V winter solar string?

At -10 C (14 F), Hanersun Technology Co Ltd CP17-72HB430W cold Voc rises from 48.8 V to 53.77 V (beta_Voc -0.291%/C), capping a 600 V string at 11 panels (591.5 V).

How much roof area does an 8 kW array of Hanersun Technology Co Ltd CP17-72HB430W need?

An 8 kW DC system uses 19 Hanersun Technology Co Ltd CP17-72HB430W modules (8,170 W STC / 7,665 W PTC), covering roughly 444 sq ft and saving ~$2,045/yr at 18.54 c/kWh.

How does Hanersun Technology Co Ltd CP17-72HB430W compare against Caterpillar Inc PVC435MP03H?

Hanersun Technology Co Ltd CP17-72HB430W outputs 430.0 W STC (48.8 V Voc, rank #7,266 of 21,677), while Caterpillar Inc PVC435MP03H delivers 435.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.