Skip to main content
WireAndSun
Calculators
CEC PV Module

Hanersun Technology Co Ltd CP17-60HB355W — CEC Solar Module Specifications

Manufacturer: Hanersun Technology Co Ltd Registry: CEC Verified Engineering Specification

Hanersun Technology Co Ltd CP17-60HB355W is a 355.0 W STC (332.9 W PTC) Mono-c-Si solar module ranking #12,724 of 21,677 CEC listings (below all-CEC median; higher than 39.9% of peers). It delivers 19.51% efficiency, 40.4 V Voc at 25 C, and 44.51 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
355.0 W
PTC Wattage
332.9 W
Voc @ 25C
40.4 V
Efficiency
19.51%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hanersun Technology Co Ltd CP17-60HB355W Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hanersun Technology Co Ltd CP17-60HB355W (Mono-c-Si) residential solar systems.

Hanersun Technology Co Ltd CP17-60HB355W delivers 195.1 W/m2 (0.40 percentage points below 19.91% CEC median) and strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (451 sq ft). At -4 F (-20 C), string voltage climbs to 45.69 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with CSI Solar Co Ltd CS3L-360MS (360.0 W).

Where Does Hanersun Technology Co Ltd CP17-60HB355W Fall Across Listed CEC Models?

Comparison of Hanersun Technology Co Ltd CP17-60HB355W (355.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hanersun Technology Co Ltd CP17-60HB355W (355.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHanersun Technolog: 355.0 W

What Dataset Percentiles Define Hanersun Technology Co Ltd CP17-60HB355W?

Relative ranking of Hanersun Technology Co Ltd CP17-60HB355W across nameplate watts, 93.8% PTC thermal ratio, and module aperture efficiency.

Hanersun Technology Co Ltd CP17-60HB355W Engineering BenchmarksPercentile comparison of Hanersun Technology Co Ltd CP17-60HB355W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage355.0 WPTC/STC Retention93.8%Module Efficiency19.51%

What Do the Dataset Ranks Show for Hanersun Technology Co Ltd CP17-60HB355W?

Summary of Hanersun Technology Co Ltd CP17-60HB355W output rank, 8 kW array size (23 panels), efficiency rating, and 600 V string limit.

Rank #12,724 / 21,677

355.0 W STC · Higher Than 39.9%

355.0 W STC (-30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,152

19.51% Aperture Efficiency

Power density 195.1 W/m2 (0.40 percentage points below 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.51 V at -10 C (578.6 V string) and 45.69 V at -20 C (13 max).

8 kW Reference Array

23 Panels = 8,165 W STC

Occupies 41.9 m2 (451 sq ft) producing 7,657 W PTC; NEC 690.8 OCPD floor is 17.44 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.4 * (1 + (-0.291/100) * (-10 - 25)) = 44.51 V | OCPD = 1.56 * 11.18 = 17.44 A

Inputs from CEC Modules.csv for Hanersun Technology Co Ltd CP17-60HB355W: Voc=40.4 V, beta_Voc=-0.291%/C, Isc=11.18 A, STC=355.0 W, Area=1.82 m2.

Result: 13 panels max on 600 V (578.6 V); 23 panels for 8 kW (451 sq ft).

What Are the Published CEC Specifications for Hanersun Technology Co Ltd CP17-60HB355W?

Complete CEC test sheet for Hanersun Technology Co Ltd CP17-60HB355W including Isc (11.18 A), Voc (40.4 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Hanersun Technology Co Ltd CP17-60HB355W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 355.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 332.9 W (93.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.18 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 33.3 V / 10.66 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.291 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.51% (1.82 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Hanersun Technology Co Ltd CP17-60HB355W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hanersun Technology Co Ltd CP17-60HB355W.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.04 kW 333 sq ft $1,512 $2,556
8 kW Class 23 8.16 kW 451 sq ft $2,042 $3,454
10 kW Class 29 10.29 kW 568 sq ft $2,575 $4,355

Which Sibling Wattage & Trim Variants Belong to This Hanersun Technology Co Ltd Series?

Related Hanersun Technology Co Ltd power steps and black/silver trims consolidated into this Hanersun Technology Co Ltd CP17-60HB355W series guide.

Sibling CEC listings grouped into the Hanersun Technology Co Ltd CP17-60HB355W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hanersun Technology Co Ltd CP17-60HB350W 350.0 W 328.1 W 40.1 V 33.0 V 19.23%
Hanersun Technology Co Ltd CP17-60HB355W 355.0 W 332.9 W 40.4 V 33.3 V 19.51%

How Many Hanersun Technology Co Ltd CP17-60HB355W Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Hanersun Technology Co Ltd CP17-60HB355W (40.4 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=40.4V and beta_Voc=-0.291%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.69 V 13 panels 594.0 V 21 panels
-10 C (14 F) 44.51 V 13 panels 578.6 V 22 panels
0 C (32 F) 43.34 V 13 panels 563.4 V 23 panels
25 C (77 F STC) 40.4 V 14 panels 565.6 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Hanersun Technology Co Ltd CP17-60HB355W?

Four comparable CEC modules such as CSI Solar Co Ltd CS3L-360MS (360.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3L-360MS
CSI Solar Co Ltd
360.0 W +5.0 W 40.4 V 20.11% 93.0%
Apollo Renewables Inc Apollo-M660BH-360BB
Apollo Renewables Inc
360.0 W +5.0 W 40.5 V 20.0% 93.6%
AXITEC AC-360MH/120V
AXITEC
360.0 W +5.0 W 40.5 V 19.89% 92.3%
AXITEC AC-360MH/120VB
AXITEC
360.0 W +5.0 W 40.5 V 19.89% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hanersun Technology Co Ltd CP17-60HB355W?

Evaluate Hanersun Technology Co Ltd CP17-60HB355W (355.0 W STC, 40.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hanersun Technology Co Ltd CP17-60HB355W reaches 45.69 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 23 panels for an 8 kW build require 451 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (451 sq ft).
  • 2026 tax credit baseline: cash residential installs of Hanersun Technology Co Ltd CP17-60HB355W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hanersun Technology Co Ltd CP17-60HB355W 8 kW Residential Fit

Needs 23 modules (451 sq ft) with a 20 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS3L-360MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 332.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hanersun Technology Co Ltd CP17-60HB355W by Hanersun Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many Hanersun Technology Co Ltd CP17-60HB355W panels fit on a 600 V winter solar string?

At -10 C (14 F), Hanersun Technology Co Ltd CP17-60HB355W cold Voc rises from 40.4 V to 44.51 V (beta_Voc -0.291%/C), capping a 600 V string at 13 panels (578.6 V).

How much roof area does an 8 kW array of Hanersun Technology Co Ltd CP17-60HB355W need?

An 8 kW DC system uses 23 Hanersun Technology Co Ltd CP17-60HB355W modules (8,165 W STC / 7,657 W PTC), covering roughly 451 sq ft and saving ~$2,042/yr at 18.54 c/kWh.

How does Hanersun Technology Co Ltd CP17-60HB355W compare against CSI Solar Co Ltd CS3L-360MS?

Hanersun Technology Co Ltd CP17-60HB355W outputs 355.0 W STC (40.4 V Voc, rank #12,724 of 21,677), while CSI Solar Co Ltd CS3L-360MS delivers 360.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.