Hanersun Energy Co Ltd HN18-72HT535W — CEC Solar Module Specifications

Manufacturer: Hanersun Energy Co Ltd Registry: CEC Verified Engineering Specification

Hanersun Energy Co Ltd HN18-72HT535W is a 535.0 W STC (505.0 W PTC) Mono-c-Si solar module ranking #3,537 of 21,677 CEC listings (top 17.5%; higher than 82.5% of peers). It delivers 21.23% efficiency, 49.45 V Voc at 25 C, and 53.83 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
535.0 W
PTC Wattage
505.0 W
Voc @ 25C
49.45 V
Efficiency
21.23%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hanersun Energy Co Ltd HN18-72HT535W Compare Against Peer CEC Listings?

How Hanersun Energy Co Ltd Hanersun Energy Co Ltd HN18-72HT535W handles rooftop heat (505.0 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Hanersun Energy Co Ltd HN18-72HT535W exhibits 13.79 A short-circuit current, requiring a 21.51 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #3,537 of 21,677 (125.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 37.8 m2 for an 8 kW system (19 panels for 10 kW). Higher 49.45 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does Hanersun Energy Co Ltd HN18-72HT535W Fall Across Listed CEC Models?

Where Hanersun Energy Co Ltd HN18-72HT535W (535.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hanersun Energy Co Ltd HN18-72HT535W (535.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHanersun Energy Co: 535.0 W

What Dataset Percentiles Define Hanersun Energy Co Ltd HN18-72HT535W?

Percentile placement of Hanersun Energy Co Ltd HN18-72HT535W across power density (212.3 W/m2), thermal retention, and nameplate STC wattage.

Hanersun Energy Co Ltd HN18-72HT535W Engineering BenchmarksPercentile comparison of Hanersun Energy Co Ltd HN18-72HT535W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage535.0 WPTC/STC Retention94.4%Module Efficiency21.23%

What Do the Dataset Ranks Show for Hanersun Energy Co Ltd HN18-72HT535W?

Four critical engineering numbers homeowners and solar installers check first when reviewing Hanersun Energy Co Ltd HN18-72HT535W specifications.

Rank #3,537 / 21,677

Top 17.5% STC Output

535.0 W STC (+150.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,486

21.23% Aperture Efficiency

Power density 212.3 W/m2 (1.32 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.83 V at -10 C (592.1 V string) and 55.08 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,025 W STC

Occupies 37.8 m2 (407 sq ft) producing 7,575 W PTC; NEC 690.8 OCPD floor is 21.51 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.45 * (1 + (-0.253/100) * (-10 - 25)) = 53.83 V | OCPD = 1.56 * 13.79 = 21.51 A

Inputs from CEC Modules.csv for Hanersun Energy Co Ltd HN18-72HT535W: Voc=49.45 V, beta_Voc=-0.253%/C, Isc=13.79 A, STC=535.0 W, Area=2.52 m2.

Result: 11 panels max on 600 V (592.1 V); 15 panels for 8 kW (407 sq ft).

What Are the Published CEC Specifications for Hanersun Energy Co Ltd HN18-72HT535W?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hanersun Energy Co Ltd HN18-72HT535W.

Official California Energy Commission (NREL SAM) test parameters for Hanersun Energy Co Ltd HN18-72HT535W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 535.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 505.0 W (94.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.45 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.79 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.47 V / 12.9 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.253 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.23% (2.52 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Hanersun Energy Co Ltd HN18-72HT535W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hanersun Energy Co Ltd HN18-72HT535W (535.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.42 kW 326 sq ft $1,607 $2,717
8 kW Class 15 8.03 kW 407 sq ft $2,010 $3,398
10 kW Class 19 10.16 kW 515 sq ft $2,543 $4,300

Which Sibling Wattage & Trim Variants Belong to This Hanersun Energy Co Ltd Series?

All closely matched Hanersun Energy Co Ltd wattages and cosmetic trims sharing the Hanersun Energy Co Ltd HN18-72HT535W architecture.

Sibling CEC listings grouped into the Hanersun Energy Co Ltd HN18-72HT535W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hanersun Energy Co Ltd HN18-72HT525W 525.0 W 495.4 W 49.15 V 41.15 V 20.83%
Hanersun Energy Co Ltd HN18-72HT530W 530.0 W 500.2 W 49.3 V 41.31 V 21.03%
Hanersun Energy Co Ltd HN18-72HT535W 535.0 W 505.0 W 49.45 V 41.47 V 21.23%
Hanersun Energy Co Ltd HN18-72HT540W 540.0 W 509.9 W 49.6 V 41.64 V 21.43%
Hanersun Energy Co Ltd HN18-72HT545W 545.0 W 514.7 W 49.75 V 41.8 V 21.63%

How Many Hanersun Energy Co Ltd HN18-72HT535W Modules Fit in a Cold-Weather String?

Maximum series module counts for Hanersun Energy Co Ltd HN18-72HT535W from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.45V and beta_Voc=-0.253%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.08 V 10 panels 550.8 V 18 panels
-10 C (14 F) 53.83 V 11 panels 592.1 V 18 panels
0 C (32 F) 52.58 V 11 panels 578.4 V 19 panels
25 C (77 F STC) 49.45 V 12 panels 593.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Hanersun Energy Co Ltd HN18-72HT535W?

Alternative CEC solar modules from competing brands near Hanersun Energy Co Ltd HN18-72HT535W (535.0 W), including Bila Solar Inc AA535US-6x24GG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Bila Solar Inc AA535US-6x24GG
Bila Solar Inc
535.0 W Tie (0 W) 49.45 V 21.31% 92.8%
ES Foundry Corp ES-DP8-H72-535
ES Foundry Corp
535.0 W Tie (0 W) 49.45 V 20.9% 93.8%
Hyperion Solar HY-DH144P8-535
Hyperion Solar
535.0 W Tie (0 W) 49.45 V 20.74% 93.0%
Hyperion Solar HY-DH144P8-535-B
Hyperion Solar
535.0 W Tie (0 W) 49.45 V 20.74% 93.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hanersun Energy Co Ltd HN18-72HT535W?

Evaluate Hanersun Energy Co Ltd HN18-72HT535W (535.0 W STC, 49.45 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hanersun Energy Co Ltd HN18-72HT535W reaches 55.08 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 407 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Hanersun Energy Co Ltd HN18-72HT535W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hanersun Energy Co Ltd HN18-72HT535W 8 kW Residential Fit

Needs 15 modules (407 sq ft) with a 25 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Bila Solar Inc AA535US-6x24GG.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 505.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hanersun Energy Co Ltd HN18-72HT535W by Hanersun Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Hanersun Energy Co Ltd HN18-72HT535W PTC wattage (505.0 W) lower than STC (535.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 505.0 W PTC (94.4% retention) across Hanersun Energy Co Ltd HN18-72HT535W's 2.52 m2 aperture.

Who should skip Hanersun Energy Co Ltd HN18-72HT535W on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 Hanersun Energy Co Ltd HN18-72HT535W panels (407 sq ft) leave unusable roof gaps vs. Bila Solar Inc AA535US-6x24GG.

What is the 1,000 V commercial string limit for Hanersun Energy Co Ltd HN18-72HT535W?

On 1,000 V commercial inverters at -10 C (53.83 V cold Voc), Hanersun Energy Co Ltd HN18-72HT535W fits up to 18 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.