Hyperion Solar HY-DH144P8-535-B — CEC Solar Module Specifications

Manufacturer: Hyperion Solar Registry: CEC Verified Engineering Specification

Hyperion Solar HY-DH144P8-535-B is a 535.0 W STC (497.3 W PTC) Mono-c-Si solar module ranking #3,537 of 21,677 CEC listings (top 17.5%; higher than 82.5% of peers). It delivers 20.74% efficiency, 49.45 V Voc at 25 C, and 54.76 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
535.0 W
PTC Wattage
497.3 W
Voc @ 25C
49.45 V
Efficiency
20.74%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hyperion Solar HY-DH144P8-535-B Compare Against Peer CEC Listings?

How Hyperion Solar Hyperion Solar HY-DH144P8-535-B handles rooftop heat (497.3 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Hyperion Solar HY-DH144P8-535-B exhibits 13.79 A short-circuit current, requiring a 21.51 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #3,537 of 21,677 (125.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 38.7 m2 for an 8 kW system (19 panels for 10 kW). Higher 49.45 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does Hyperion Solar HY-DH144P8-535-B Fall Across Listed CEC Models?

Where Hyperion Solar HY-DH144P8-535-B (535.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hyperion Solar HY-DH144P8-535-B (535.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHyperion Solar HY-: 535.0 W

What Dataset Percentiles Define Hyperion Solar HY-DH144P8-535-B?

Percentile placement of Hyperion Solar HY-DH144P8-535-B across power density (207.4 W/m2), thermal retention, and nameplate STC wattage.

Hyperion Solar HY-DH144P8-535-B Engineering BenchmarksPercentile comparison of Hyperion Solar HY-DH144P8-535-B wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage535.0 WPTC/STC Retention93.0%Module Efficiency20.74%

What Do the Dataset Ranks Show for Hyperion Solar HY-DH144P8-535-B?

Four critical engineering numbers homeowners and solar installers check first when reviewing Hyperion Solar HY-DH144P8-535-B specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #3,537 / 21,677

Top 17.5% STC Output

535.0 W STC (+150.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,518

20.74% Aperture Efficiency

Power density 207.4 W/m2 (0.83 percentage points above 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.76 V at -10 C (547.6 V string) and 56.28 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,025 W STC

Occupies 38.7 m2 (417 sq ft) producing 7,460 W PTC; NEC 690.8 OCPD floor is 21.51 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.45 * (1 + (-0.307/100) * (-10 - 25)) = 54.76 V | OCPD = 1.56 * 13.79 = 21.51 A

Inputs from CEC Modules.csv for Hyperion Solar HY-DH144P8-535-B: Voc=49.45 V, beta_Voc=-0.307%/C, Isc=13.79 A, STC=535.0 W, Area=2.58 m2.

Result: 10 panels max on 600 V (547.6 V); 15 panels for 8 kW (417 sq ft).

What Are the Published CEC Specifications for Hyperion Solar HY-DH144P8-535-B?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hyperion Solar HY-DH144P8-535-B.

Official California Energy Commission (NREL SAM) test parameters for Hyperion Solar HY-DH144P8-535-B.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 535.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 497.3 W (93.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.45 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.79 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.47 V / 12.9 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.307 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.74% (2.58 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Hyperion Solar HY-DH144P8-535-B Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hyperion Solar HY-DH144P8-535-B (535.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.42 kW 333 sq ft $1,607 $2,717
8 kW Class 15 8.03 kW 417 sq ft $2,010 $3,398
10 kW Class 19 10.16 kW 528 sq ft $2,543 $4,300

Which Sibling Wattage & Trim Variants Belong to This Hyperion Solar Series?

All closely matched Hyperion Solar wattages and cosmetic trims sharing the Hyperion Solar HY-DH144P8-535-B architecture. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the Hyperion Solar HY-DH144P8-535-B wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hyperion Solar HY-DH144P8-525-B 525.0 W 487.7 W 49.15 V 41.15 V 20.35%
Hyperion Solar HY-DH144P8-530-B 530.0 W 492.5 W 49.3 V 41.31 V 20.54%
Hyperion Solar HY-DH144P8-535-B 535.0 W 497.3 W 49.45 V 41.47 V 20.74%
Hyperion Solar HY-DH144P8-540-B 540.0 W 502.1 W 49.6 V 41.64 V 20.93%
Hyperion Solar HY-DH144P8-545-B 545.0 W 506.9 W 49.75 V 41.8 V 21.12%

How Many Hyperion Solar HY-DH144P8-535-B Modules Fit in a Cold-Weather String?

Maximum series module counts for Hyperion Solar HY-DH144P8-535-B from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.45V and beta_Voc=-0.307%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.28 V 10 panels 562.8 V 17 panels
-10 C (14 F) 54.76 V 10 panels 547.6 V 18 panels
0 C (32 F) 53.25 V 11 panels 585.8 V 18 panels
25 C (77 F STC) 49.45 V 12 panels 593.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Hyperion Solar HY-DH144P8-535-B?

Alternative CEC solar modules from competing brands near Hyperion Solar HY-DH144P8-535-B (535.0 W), including Bila Solar Inc AA535US-6x24GG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Bila Solar Inc AA535US-6x24GG
Bila Solar Inc
535.0 W Tie (0 W) 49.45 V 21.31% 92.8%
ES Foundry Corp ES-DP8-H72-535
ES Foundry Corp
535.0 W Tie (0 W) 49.45 V 20.9% 93.8%
Hanersun Energy Co Ltd HN18-72HT535W
Hanersun Energy Co Ltd
535.0 W Tie (0 W) 49.45 V 21.23% 94.4%
G-Star Pte Ltd GSP7G72M(H)535WT
G-Star Pte Ltd
535.0 W Tie (0 W) 49.46 V 20.9% 94.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hyperion Solar HY-DH144P8-535-B?

Evaluate Hyperion Solar HY-DH144P8-535-B (535.0 W STC, 49.45 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hyperion Solar HY-DH144P8-535-B reaches 56.28 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Hyperion Solar HY-DH144P8-535-B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hyperion Solar HY-DH144P8-535-B 8 kW Residential Fit

Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Bila Solar Inc AA535US-6x24GG.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 497.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hyperion Solar HY-DH144P8-535-B by Hyperion Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Hyperion Solar HY-DH144P8-535-B PTC wattage (497.3 W) lower than STC (535.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 497.3 W PTC (93.0% retention) across Hyperion Solar HY-DH144P8-535-B's 2.58 m2 aperture.

Who should skip Hyperion Solar HY-DH144P8-535-B on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 Hyperion Solar HY-DH144P8-535-B panels (417 sq ft) leave unusable roof gaps vs. Bila Solar Inc AA535US-6x24GG.

What is the 1,000 V commercial string limit for Hyperion Solar HY-DH144P8-535-B?

On 1,000 V commercial inverters at -10 C (54.76 V cold Voc), Hyperion Solar HY-DH144P8-535-B fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Hyperion Solar HY-DH144P8-535-B.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls