Hyperion Solar HY-DH144P8-550-B is a 550.0 W STC (511.6 W PTC) Mono-c-Si solar module ranking #2,737 of 21,677 CEC listings (top 13.8%; higher than 86.2% of peers). It delivers 21.32% efficiency, 49.9 V Voc at 25 C, and 55.26 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 550.0 W
- PTC Wattage
- 511.6 W
- Voc @ 25C
- 49.9 V
- Efficiency
- 21.32%
How Does Hyperion Solar HY-DH144P8-550-B Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hyperion Solar HY-DH144P8-550-B (Mono-c-Si) residential solar systems.
Homeowners evaluating Hyperion Solar HY-DH144P8-550-B need 11 panels for 6 kW or 15 panels (417 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.307%/C) pushes open-circuit voltage to 55.26 V at 14 F and 56.79 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.
Where Does Hyperion Solar HY-DH144P8-550-B Fall Across Listed CEC Models?
Comparison of Hyperion Solar HY-DH144P8-550-B (550.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Dataset Percentiles Define Hyperion Solar HY-DH144P8-550-B?
Relative ranking of Hyperion Solar HY-DH144P8-550-B across nameplate watts, 93.0% PTC thermal ratio, and module aperture efficiency. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
What Do the Dataset Ranks Show for Hyperion Solar HY-DH144P8-550-B?
Summary of Hyperion Solar HY-DH144P8-550-B output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.
Top 13.8% STC Output
550.0 W STC (+165.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.32% Aperture Efficiency
Power density 213.2 W/m2 (1.41 percentage points above 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 55.26 V at -10 C (552.6 V string) and 56.79 V at -20 C (10 max).
15 Panels = 8,250 W STC
Occupies 38.7 m2 (417 sq ft) producing 7,674 W PTC; NEC 690.8 OCPD floor is 21.84 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.9 * (1 + (-0.307/100) * (-10 - 25)) = 55.26 V | OCPD = 1.56 * 14.0 = 21.84 A
Inputs from CEC Modules.csv for Hyperion Solar HY-DH144P8-550-B: Voc=49.9 V, beta_Voc=-0.307%/C, Isc=14.0 A, STC=550.0 W, Area=2.58 m2.
Result: 10 panels max on 600 V (552.6 V); 15 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for Hyperion Solar HY-DH144P8-550-B?
Complete CEC test sheet for Hyperion Solar HY-DH144P8-550-B including Isc (14.0 A), Voc (49.9 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 550.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 511.6 W (93.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.0 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.96 V / 13.11 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.307 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.32% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Hyperion Solar HY-DH144P8-550-B Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hyperion Solar HY-DH144P8-550-B.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.05 kW | 305 sq ft | $1,514 | $2,561 |
| 8 kW Class | 15 | 8.25 kW | 417 sq ft | $2,065 | $3,492 |
| 10 kW Class | 19 | 10.45 kW | 528 sq ft | $2,616 | $4,423 |
How Many Hyperion Solar HY-DH144P8-550-B Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Hyperion Solar HY-DH144P8-550-B (49.9 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.79 V | 10 panels | 567.9 V | 17 panels |
| -10 C (14 F) | 55.26 V | 10 panels | 552.6 V | 18 panels |
| 0 C (32 F) | 53.73 V | 11 panels | 591.0 V | 18 panels |
| 25 C (77 F STC) | 49.9 V | 12 panels | 598.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Hyperion Solar HY-DH144P8-550-B?
Four comparable CEC modules such as AMPS Solar AMPS-550P-144BB (550.0 W) for side-by-side solar quote checks. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AMPS Solar AMPS-550P-144BB AMPS Solar |
550.0 W | Tie (0 W) | 49.9 V | 28.95% | 94.1% |
| Apollo Renewables Inc Apollo-M772BH-550TW Apollo Renewables Inc |
550.0 W | Tie (0 W) | 49.9 V | 21.48% | 93.6% |
| Exiom Solution S A EX550-144BMH-DG Exiom Solution S A |
550.0 W | Tie (0 W) | 49.9 V | 21.32% | 93.4% |
| Exiom Solution S A EX550-144M-BMH Exiom Solution S A |
550.0 W | Tie (0 W) | 49.9 V | 21.32% | 93.7% |
What Are the Design Limits and Best-Fit Uses for Hyperion Solar HY-DH144P8-550-B?
Evaluate Hyperion Solar HY-DH144P8-550-B (550.0 W STC, 49.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hyperion Solar HY-DH144P8-550-B reaches 56.79 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Hyperion Solar HY-DH144P8-550-B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hyperion Solar HY-DH144P8-550-B 8 kW Residential Fit
Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare AMPS Solar AMPS-550P-144BB.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 511.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hyperion Solar HY-DH144P8-550-B by Hyperion Solar grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Hyperion Solar HY-DH144P8-550-B PTC wattage (511.6 W) lower than STC (550.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 511.6 W PTC (93.0% retention) across Hyperion Solar HY-DH144P8-550-B's 2.58 m2 aperture.
Who should skip Hyperion Solar HY-DH144P8-550-B on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 Hyperion Solar HY-DH144P8-550-B panels (417 sq ft) leave unusable roof gaps vs. AMPS Solar AMPS-550P-144BB.
What is the 1,000 V commercial string limit for Hyperion Solar HY-DH144P8-550-B?
On 1,000 V commercial inverters at -10 C (55.26 V cold Voc), Hyperion Solar HY-DH144P8-550-B fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Hyperion Solar HY-DH144P8-550-B.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)