Manufacturer: Hyperion Solar Registry: CEC Verified Engineering Specification

Hyperion Solar HY-DH144P8-550 is a 550.0 W STC (511.6 W PTC) Mono-c-Si solar module ranking #2,737 of 21,677 CEC listings (top 13.8%; higher than 86.2% of peers). It delivers 21.32% efficiency, 49.9 V Voc at 25 C, and 55.26 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
550.0 W
PTC Wattage
511.6 W
Voc @ 25C
49.9 V
Efficiency
21.32%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hyperion Solar HY-DH144P8-550 Compare Against Peer CEC Listings?

Solar engineering breakdown for Hyperion Solar HY-DH144P8-550: PTC thermal retention, roof footprint, and cold Voc string bounds. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Measured at 550.0 W STC and 511.6 W PTC, Hyperion Solar HY-DH144P8-550 sits +165.0 W vs all-CEC median (top 13.8%; higher than 86.2% of peers) among 21,677 listed modules. Power density reaches 213.2 W/m2 (1.41 percentage points above 19.91% CEC median). Higher 49.9 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer AMPS Solar AMPS-550P-144BB rates 550.0 W.

Where Does Hyperion Solar HY-DH144P8-550 Fall Across Listed CEC Models?

Distribution marker showing Hyperion Solar HY-DH144P8-550 (550.0 W) relative to the 385.0 W all-CEC solar panel median. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hyperion Solar HY-DH144P8-550 (550.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHyperion Solar HY-: 550.0 W

What Dataset Percentiles Define Hyperion Solar HY-DH144P8-550?

Dataset percentiles tracking Hyperion Solar HY-DH144P8-550 power output, thermal retention ratio, and aperture efficiency against 21,677 models. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Hyperion Solar HY-DH144P8-550 Engineering BenchmarksPercentile comparison of Hyperion Solar HY-DH144P8-550 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage550.0 WPTC/STC Retention93.0%Module Efficiency21.32%

What Do the Dataset Ranks Show for Hyperion Solar HY-DH144P8-550?

Benchmark highlights for Hyperion Solar HY-DH144P8-550 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #2,737 / 21,677

Top 13.8% STC Output

550.0 W STC (+165.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,973

21.32% Aperture Efficiency

Power density 213.2 W/m2 (1.41 percentage points above 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.26 V at -10 C (552.6 V string) and 56.79 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,250 W STC

Occupies 38.7 m2 (417 sq ft) producing 7,674 W PTC; NEC 690.8 OCPD floor is 21.84 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.9 * (1 + (-0.307/100) * (-10 - 25)) = 55.26 V | OCPD = 1.56 * 14.0 = 21.84 A

Inputs from CEC Modules.csv for Hyperion Solar HY-DH144P8-550: Voc=49.9 V, beta_Voc=-0.307%/C, Isc=14.0 A, STC=550.0 W, Area=2.58 m2.

Result: 10 panels max on 600 V (552.6 V); 15 panels for 8 kW (417 sq ft).

What Are the Published CEC Specifications for Hyperion Solar HY-DH144P8-550?

Official CEC datasheet figures for Hyperion Solar HY-DH144P8-550 (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Official California Energy Commission (NREL SAM) test parameters for Hyperion Solar HY-DH144P8-550.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 550.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 511.6 W (93.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.0 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.96 V / 13.11 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.307 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.32% (2.58 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Hyperion Solar HY-DH144P8-550 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Hyperion Solar HY-DH144P8-550 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.05 kW 305 sq ft $1,514 $2,561
8 kW Class 15 8.25 kW 417 sq ft $2,065 $3,492
10 kW Class 19 10.45 kW 528 sq ft $2,616 $4,423

How Many Hyperion Solar HY-DH144P8-550 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Hyperion Solar HY-DH144P8-550 (55.26 V at 14 F).

Computed from Voc=49.9V and beta_Voc=-0.307%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.79 V 10 panels 567.9 V 17 panels
-10 C (14 F) 55.26 V 10 panels 552.6 V 18 panels
0 C (32 F) 53.73 V 11 panels 591.0 V 18 panels
25 C (77 F STC) 49.9 V 12 panels 598.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Hyperion Solar HY-DH144P8-550?

Competing CEC solar panels closest to Hyperion Solar HY-DH144P8-550 in nameplate wattage and Voc, starting with AMPS Solar AMPS-550P-144BB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AMPS Solar AMPS-550P-144BB
AMPS Solar
550.0 W Tie (0 W) 49.9 V 28.95% 94.1%
Apollo Renewables Inc Apollo-M772BH-550TW
Apollo Renewables Inc
550.0 W Tie (0 W) 49.9 V 21.48% 93.6%
Exiom Solution S A EX550-144BMH-DG
Exiom Solution S A
550.0 W Tie (0 W) 49.9 V 21.32% 93.4%
Exiom Solution S A EX550-144M-BMH
Exiom Solution S A
550.0 W Tie (0 W) 49.9 V 21.32% 93.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hyperion Solar HY-DH144P8-550?

Evaluate Hyperion Solar HY-DH144P8-550 (550.0 W STC, 49.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hyperion Solar HY-DH144P8-550 reaches 56.79 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Hyperion Solar HY-DH144P8-550 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hyperion Solar HY-DH144P8-550 8 kW Residential Fit

Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare AMPS Solar AMPS-550P-144BB.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 511.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hyperion Solar HY-DH144P8-550 by Hyperion Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Hyperion Solar HY-DH144P8-550 panels fit on a 600 V winter solar string?

At -10 C (14 F), Hyperion Solar HY-DH144P8-550 cold Voc rises from 49.9 V to 55.26 V (beta_Voc -0.307%/C), capping a 600 V string at 10 panels (552.6 V).

How much roof area does an 8 kW array of Hyperion Solar HY-DH144P8-550 need?

An 8 kW DC system uses 15 Hyperion Solar HY-DH144P8-550 modules (8,250 W STC / 7,674 W PTC), covering roughly 417 sq ft and saving ~$2,065/yr at 18.54 c/kWh.

How does Hyperion Solar HY-DH144P8-550 compare against AMPS Solar AMPS-550P-144BB?

Hyperion Solar HY-DH144P8-550 outputs 550.0 W STC (49.9 V Voc, rank #2,737 of 21,677), while AMPS Solar AMPS-550P-144BB delivers 550.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.