Skip to main content
WireAndSun
Calculators
CEC PV Module

Hyperion Solar HY-DH144P8-535 — CEC Solar Module Specifications

Manufacturer: Hyperion Solar Registry: CEC Verified Engineering Specification

Hyperion Solar HY-DH144P8-535 is a 535.0 W STC (497.3 W PTC) Mono-c-Si solar module ranking #3,537 of 21,677 CEC listings (top 17.5%; higher than 82.5% of peers). It delivers 20.74% efficiency, 49.45 V Voc at 25 C, and 54.76 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
535.0 W
PTC Wattage
497.3 W
Voc @ 25C
49.45 V
Efficiency
20.74%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hyperion Solar HY-DH144P8-535 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hyperion Solar HY-DH144P8-535 (Mono-c-Si) residential solar systems.

Hyperion Solar HY-DH144P8-535 delivers 207.4 W/m2 (0.83 percentage points above 19.91% CEC median) and strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 56.28 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with Bila Solar Inc AA535US-6x24GG (535.0 W).

Where Does Hyperion Solar HY-DH144P8-535 Fall Across Listed CEC Models?

Comparison of Hyperion Solar HY-DH144P8-535 (535.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hyperion Solar HY-DH144P8-535 (535.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHyperion Solar HY-: 535.0 W

What Dataset Percentiles Define Hyperion Solar HY-DH144P8-535?

Relative ranking of Hyperion Solar HY-DH144P8-535 across nameplate watts, 93.0% PTC thermal ratio, and module aperture efficiency. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Hyperion Solar HY-DH144P8-535 Engineering BenchmarksPercentile comparison of Hyperion Solar HY-DH144P8-535 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage535.0 WPTC/STC Retention93.0%Module Efficiency20.74%

What Do the Dataset Ranks Show for Hyperion Solar HY-DH144P8-535?

Summary of Hyperion Solar HY-DH144P8-535 output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.

Rank #3,537 / 21,677

Top 17.5% STC Output

535.0 W STC (+150.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,518

20.74% Aperture Efficiency

Power density 207.4 W/m2 (0.83 percentage points above 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.76 V at -10 C (547.6 V string) and 56.28 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,025 W STC

Occupies 38.7 m2 (417 sq ft) producing 7,460 W PTC; NEC 690.8 OCPD floor is 21.51 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.45 * (1 + (-0.307/100) * (-10 - 25)) = 54.76 V | OCPD = 1.56 * 13.79 = 21.51 A

Inputs from CEC Modules.csv for Hyperion Solar HY-DH144P8-535: Voc=49.45 V, beta_Voc=-0.307%/C, Isc=13.79 A, STC=535.0 W, Area=2.58 m2.

Result: 10 panels max on 600 V (547.6 V); 15 panels for 8 kW (417 sq ft).

What Are the Published CEC Specifications for Hyperion Solar HY-DH144P8-535?

Complete CEC test sheet for Hyperion Solar HY-DH144P8-535 including Isc (13.79 A), Voc (49.45 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Hyperion Solar HY-DH144P8-535.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 535.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 497.3 W (93.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.45 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.79 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.47 V / 12.9 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.307 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.74% (2.58 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Hyperion Solar HY-DH144P8-535 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hyperion Solar HY-DH144P8-535.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.42 kW 333 sq ft $1,607 $2,717
8 kW Class 15 8.03 kW 417 sq ft $2,010 $3,398
10 kW Class 19 10.16 kW 528 sq ft $2,543 $4,300

Which Sibling Wattage & Trim Variants Belong to This Hyperion Solar Series?

Related Hyperion Solar power steps and black/silver trims consolidated into this Hyperion Solar HY-DH144P8-535 series guide. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the Hyperion Solar HY-DH144P8-535 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hyperion Solar HY-DH144P8-525 525.0 W 487.7 W 49.15 V 41.15 V 20.35%
Hyperion Solar HY-DH144P8-530 530.0 W 492.5 W 49.3 V 41.31 V 20.54%
Hyperion Solar HY-DH144P8-535 535.0 W 497.3 W 49.45 V 41.47 V 20.74%
Hyperion Solar HY-DH144P8-540 540.0 W 502.1 W 49.6 V 41.64 V 20.93%
Hyperion Solar HY-DH144P8-545 545.0 W 506.9 W 49.75 V 41.8 V 21.12%

How Many Hyperion Solar HY-DH144P8-535 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Hyperion Solar HY-DH144P8-535 (49.45 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=49.45V and beta_Voc=-0.307%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.28 V 10 panels 562.8 V 17 panels
-10 C (14 F) 54.76 V 10 panels 547.6 V 18 panels
0 C (32 F) 53.25 V 11 panels 585.8 V 18 panels
25 C (77 F STC) 49.45 V 12 panels 593.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Hyperion Solar HY-DH144P8-535?

Four comparable CEC modules such as Bila Solar Inc AA535US-6x24GG (535.0 W) for side-by-side solar quote checks. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Bila Solar Inc AA535US-6x24GG
Bila Solar Inc
535.0 W Tie (0 W) 49.45 V 21.31% 92.8%
ES Foundry Corp ES-DP8-H72-535
ES Foundry Corp
535.0 W Tie (0 W) 49.45 V 20.9% 93.8%
Hanersun Energy Co Ltd HN18-72HT535W
Hanersun Energy Co Ltd
535.0 W Tie (0 W) 49.45 V 21.23% 94.4%
G-Star Pte Ltd GSP7G72M(H)535WT
G-Star Pte Ltd
535.0 W Tie (0 W) 49.46 V 20.9% 94.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hyperion Solar HY-DH144P8-535?

Evaluate Hyperion Solar HY-DH144P8-535 (535.0 W STC, 49.45 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hyperion Solar HY-DH144P8-535 reaches 56.28 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Hyperion Solar HY-DH144P8-535 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hyperion Solar HY-DH144P8-535 8 kW Residential Fit

Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Bila Solar Inc AA535US-6x24GG.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 497.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hyperion Solar HY-DH144P8-535 by Hyperion Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Hyperion Solar HY-DH144P8-535 panels fit on a 600 V winter solar string?

At -10 C (14 F), Hyperion Solar HY-DH144P8-535 cold Voc rises from 49.45 V to 54.76 V (beta_Voc -0.307%/C), capping a 600 V string at 10 panels (547.6 V).

How much roof area does an 8 kW array of Hyperion Solar HY-DH144P8-535 need?

An 8 kW DC system uses 15 Hyperion Solar HY-DH144P8-535 modules (8,025 W STC / 7,460 W PTC), covering roughly 417 sq ft and saving ~$2,010/yr at 18.54 c/kWh.

How does Hyperion Solar HY-DH144P8-535 compare against Bila Solar Inc AA535US-6x24GG?

Hyperion Solar HY-DH144P8-535 outputs 535.0 W STC (49.45 V Voc, rank #3,537 of 21,677), while Bila Solar Inc AA535US-6x24GG delivers 535.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.