FreeVolt ECP-PVGRAF-72HC-395W — CEC Solar Module Specifications

Manufacturer: FreeVolt Registry: CEC Verified Engineering Specification

FreeVolt ECP-PVGRAF-72HC-395W is a 395.0 W STC (365.4 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.68% efficiency, 48.7 V Voc at 25 C, and 53.18 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
395.0 W
PTC Wattage
365.4 W
Voc @ 25C
48.7 V
Efficiency
20.68%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does FreeVolt ECP-PVGRAF-72HC-395W Compare Against Peer CEC Listings?

How FreeVolt FreeVolt ECP-PVGRAF-72HC-395W handles rooftop heat (365.4 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, FreeVolt ECP-PVGRAF-72HC-395W exhibits 10.37 A short-circuit current, requiring a 16.18 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #9,869 of 21,677 (15.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 40.1 m2 for an 8 kW system (26 panels for 10 kW). Higher 48.7 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does FreeVolt ECP-PVGRAF-72HC-395W Fall Across Listed CEC Models?

Where FreeVolt ECP-PVGRAF-72HC-395W (395.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where FreeVolt ECP-PVGRAF-72HC-395W (395.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFreeVolt ECP-PVGRA: 395.0 W

What Dataset Percentiles Define FreeVolt ECP-PVGRAF-72HC-395W?

Percentile placement of FreeVolt ECP-PVGRAF-72HC-395W across power density (206.8 W/m2), thermal retention, and nameplate STC wattage. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

FreeVolt ECP-PVGRAF-72HC-395W Engineering BenchmarksPercentile comparison of FreeVolt ECP-PVGRAF-72HC-395W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage395.0 WPTC/STC Retention92.5%Module Efficiency20.68%

What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-72HC-395W?

Four critical engineering numbers homeowners and solar installers check first when reviewing FreeVolt ECP-PVGRAF-72HC-395W specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rank #9,869 / 21,677

Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,852

20.68% Aperture Efficiency

Power density 206.8 W/m2 (0.77 percentage points above 19.91% CEC median). PTC/STC ratio: 92.5% (rank #12,531).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.18 V at -10 C (585.0 V string) and 54.46 V at -20 C (11 max).

8 kW Reference Array

21 Panels = 8,295 W STC

Occupies 40.1 m2 (432 sq ft) producing 7,673 W PTC; NEC 690.8 OCPD floor is 16.18 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.7 * (1 + (-0.263/100) * (-10 - 25)) = 53.18 V | OCPD = 1.56 * 10.37 = 16.18 A

Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-72HC-395W: Voc=48.7 V, beta_Voc=-0.263%/C, Isc=10.37 A, STC=395.0 W, Area=1.91 m2.

Result: 11 panels max on 600 V (585.0 V); 21 panels for 8 kW (432 sq ft).

What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-72HC-395W?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for FreeVolt ECP-PVGRAF-72HC-395W. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for FreeVolt ECP-PVGRAF-72HC-395W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 395.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 365.4 W (92.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.37 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.1 V / 9.86 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.263 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.68% (1.91 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many FreeVolt ECP-PVGRAF-72HC-395W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using FreeVolt ECP-PVGRAF-72HC-395W (395.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.32 kW 329 sq ft $1,582 $2,675
8 kW Class 21 8.29 kW 432 sq ft $2,075 $3,509
10 kW Class 26 10.27 kW 535 sq ft $2,570 $4,347

How Many FreeVolt ECP-PVGRAF-72HC-395W Modules Fit in a Cold-Weather String?

Maximum series module counts for FreeVolt ECP-PVGRAF-72HC-395W from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=48.7V and beta_Voc=-0.263%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.46 V 11 panels 599.1 V 18 panels
-10 C (14 F) 53.18 V 11 panels 585.0 V 18 panels
0 C (32 F) 51.9 V 11 panels 570.9 V 19 panels
25 C (77 F STC) 48.7 V 12 panels 584.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-72HC-395W?

Alternative CEC solar modules from competing brands near FreeVolt ECP-PVGRAF-72HC-395W (395.0 W), including Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
395.0 W Tie (0 W) 48.7 V 20.26% 92.9%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-395W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
395.0 W Tie (0 W) 48.7 V 20.68% 92.5%
Dehui Solar Power (Vietnam) CoLtd DH-M872F 395W
Dehui Solar Power (Vietnam) CoLtd
395.0 W Tie (0 W) 48.7 V 20.26% 92.9%
Dehui Solar Power (Vietnam) CoLtd DH-M872W 395W
Dehui Solar Power (Vietnam) CoLtd
395.0 W Tie (0 W) 48.7 V 20.68% 92.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-72HC-395W?

Evaluate FreeVolt ECP-PVGRAF-72HC-395W (395.0 W STC, 48.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-72HC-395W reaches 54.46 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 432 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (432 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-72HC-395W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

FreeVolt ECP-PVGRAF-72HC-395W 8 kW Residential Fit

Needs 21 modules (432 sq ft) with a 20 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 365.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for FreeVolt ECP-PVGRAF-72HC-395W by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Why is FreeVolt ECP-PVGRAF-72HC-395W PTC wattage (365.4 W) lower than STC (395.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 365.4 W PTC (92.5% retention) across FreeVolt ECP-PVGRAF-72HC-395W's 1.91 m2 aperture.

Who should skip FreeVolt ECP-PVGRAF-72HC-395W on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 FreeVolt ECP-PVGRAF-72HC-395W panels (432 sq ft) leave unusable roof gaps vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W.

What is the 1,000 V commercial string limit for FreeVolt ECP-PVGRAF-72HC-395W?

On 1,000 V commercial inverters at -10 C (53.18 V cold Voc), FreeVolt ECP-PVGRAF-72HC-395W fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting FreeVolt ECP-PVGRAF-72HC-395W.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.