FreeVolt ECP-PVGRAF-72HC-395W is a 395.0 W STC (365.4 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.68% efficiency, 48.7 V Voc at 25 C, and 53.18 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 365.4 W
- Voc @ 25C
- 48.7 V
- Efficiency
- 20.68%
How Does FreeVolt ECP-PVGRAF-72HC-395W Compare Against Peer CEC Listings?
How FreeVolt FreeVolt ECP-PVGRAF-72HC-395W handles rooftop heat (365.4 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, FreeVolt ECP-PVGRAF-72HC-395W exhibits 10.37 A short-circuit current, requiring a 16.18 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #9,869 of 21,677 (15.0 W below the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 40.1 m2 for an 8 kW system (26 panels for 10 kW). Higher 48.7 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does FreeVolt ECP-PVGRAF-72HC-395W Fall Across Listed CEC Models?
Where FreeVolt ECP-PVGRAF-72HC-395W (395.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define FreeVolt ECP-PVGRAF-72HC-395W?
Percentile placement of FreeVolt ECP-PVGRAF-72HC-395W across power density (206.8 W/m2), thermal retention, and nameplate STC wattage. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-72HC-395W?
Four critical engineering numbers homeowners and solar installers check first when reviewing FreeVolt ECP-PVGRAF-72HC-395W specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.68% Aperture Efficiency
Power density 206.8 W/m2 (0.77 percentage points above 19.91% CEC median). PTC/STC ratio: 92.5% (rank #12,531).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.18 V at -10 C (585.0 V string) and 54.46 V at -20 C (11 max).
21 Panels = 8,295 W STC
Occupies 40.1 m2 (432 sq ft) producing 7,673 W PTC; NEC 690.8 OCPD floor is 16.18 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.7 * (1 + (-0.263/100) * (-10 - 25)) = 53.18 V | OCPD = 1.56 * 10.37 = 16.18 A
Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-72HC-395W: Voc=48.7 V, beta_Voc=-0.263%/C, Isc=10.37 A, STC=395.0 W, Area=1.91 m2.
Result: 11 panels max on 600 V (585.0 V); 21 panels for 8 kW (432 sq ft).
What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-72HC-395W?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for FreeVolt ECP-PVGRAF-72HC-395W. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 365.4 W (92.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.37 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.1 V / 9.86 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.263 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.68% (1.91 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many FreeVolt ECP-PVGRAF-72HC-395W Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using FreeVolt ECP-PVGRAF-72HC-395W (395.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 329 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 432 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 535 sq ft | $2,570 | $4,347 |
How Many FreeVolt ECP-PVGRAF-72HC-395W Modules Fit in a Cold-Weather String?
Maximum series module counts for FreeVolt ECP-PVGRAF-72HC-395W from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.46 V | 11 panels | 599.1 V | 18 panels |
| -10 C (14 F) | 53.18 V | 11 panels | 585.0 V | 18 panels |
| 0 C (32 F) | 51.9 V | 11 panels | 570.9 V | 19 panels |
| 25 C (77 F STC) | 48.7 V | 12 panels | 584.4 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-72HC-395W?
Alternative CEC solar modules from competing brands near FreeVolt ECP-PVGRAF-72HC-395W (395.0 W), including Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
395.0 W | Tie (0 W) | 48.7 V | 20.26% | 92.9% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-395W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
395.0 W | Tie (0 W) | 48.7 V | 20.68% | 92.5% |
| Dehui Solar Power (Vietnam) CoLtd DH-M872F 395W Dehui Solar Power (Vietnam) CoLtd |
395.0 W | Tie (0 W) | 48.7 V | 20.26% | 92.9% |
| Dehui Solar Power (Vietnam) CoLtd DH-M872W 395W Dehui Solar Power (Vietnam) CoLtd |
395.0 W | Tie (0 W) | 48.7 V | 20.68% | 92.5% |
What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-72HC-395W?
Evaluate FreeVolt ECP-PVGRAF-72HC-395W (395.0 W STC, 48.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-72HC-395W reaches 54.46 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 432 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (432 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-72HC-395W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
FreeVolt ECP-PVGRAF-72HC-395W 8 kW Residential Fit
Needs 21 modules (432 sq ft) with a 20 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 365.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for FreeVolt ECP-PVGRAF-72HC-395W by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
Why is FreeVolt ECP-PVGRAF-72HC-395W PTC wattage (365.4 W) lower than STC (395.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 365.4 W PTC (92.5% retention) across FreeVolt ECP-PVGRAF-72HC-395W's 1.91 m2 aperture.
Who should skip FreeVolt ECP-PVGRAF-72HC-395W on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 21 FreeVolt ECP-PVGRAF-72HC-395W panels (432 sq ft) leave unusable roof gaps vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W.
What is the 1,000 V commercial string limit for FreeVolt ECP-PVGRAF-72HC-395W?
On 1,000 V commercial inverters at -10 C (53.18 V cold Voc), FreeVolt ECP-PVGRAF-72HC-395W fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting FreeVolt ECP-PVGRAF-72HC-395W.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)