FreeVolt ECP-PVGRAF-72BHC-395W is a 395.0 W STC (367.1 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.26% efficiency, 48.7 V Voc at 25 C, and 53.15 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 367.1 W
- Voc @ 25C
- 48.7 V
- Efficiency
- 20.26%
How Does FreeVolt ECP-PVGRAF-72BHC-395W Compare Against Peer CEC Listings?
Solar engineering breakdown for FreeVolt ECP-PVGRAF-72BHC-395W: PTC thermal retention, roof footprint, and cold Voc string bounds. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
Across 5,889 Mono-c-Si listings from FreeVolt and peers, FreeVolt ECP-PVGRAF-72BHC-395W stands 15.0 W below the 410.0 W Mono-c-Si median and strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677). Sizing 6 kW (16 panels) to 10 kW (26 panels) yields $1,582-$2,570/yr in baseline US bill offset. Higher 48.7 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does FreeVolt ECP-PVGRAF-72BHC-395W Fall Across Listed CEC Models?
Distribution marker showing FreeVolt ECP-PVGRAF-72BHC-395W (395.0 W) relative to the 385.0 W all-CEC solar panel median. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Dataset Percentiles Define FreeVolt ECP-PVGRAF-72BHC-395W?
Dataset percentiles tracking FreeVolt ECP-PVGRAF-72BHC-395W power output, thermal retention ratio, and aperture efficiency against 21,677 models. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-72BHC-395W?
Benchmark highlights for FreeVolt ECP-PVGRAF-72BHC-395W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.26% Aperture Efficiency
Power density 202.6 W/m2 (0.35 percentage points above 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.15 V at -10 C (584.6 V string) and 54.42 V at -20 C (11 max).
21 Panels = 8,295 W STC
Occupies 40.9 m2 (441 sq ft) producing 7,709 W PTC; NEC 690.8 OCPD floor is 16.05 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.7 * (1 + (-0.261/100) * (-10 - 25)) = 53.15 V | OCPD = 1.56 * 10.29 = 16.05 A
Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-72BHC-395W: Voc=48.7 V, beta_Voc=-0.261%/C, Isc=10.29 A, STC=395.0 W, Area=1.95 m2.
Result: 11 panels max on 600 V (584.6 V); 21 panels for 8 kW (441 sq ft).
What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-72BHC-395W?
Official CEC datasheet figures for FreeVolt ECP-PVGRAF-72BHC-395W (Mono-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 367.1 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.29 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.5 V / 9.76 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.261 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.26% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many FreeVolt ECP-PVGRAF-72BHC-395W Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many FreeVolt ECP-PVGRAF-72BHC-395W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 336 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 441 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 546 sq ft | $2,570 | $4,347 |
Which Sibling Wattage & Trim Variants Belong to This FreeVolt Series?
Consolidated FreeVolt wattage variants sharing the FreeVolt ECP-PVGRAF-72BHC-395W mechanical and cell layout. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| FreeVolt ECP-PVGRAF-72BHC-390W | 390.0 W | 362.3 W | 48.5 V | 40.2 V | 20.0% |
| FreeVolt ECP-PVGRAF-72BHC-395W | 395.0 W | 367.1 W | 48.7 V | 40.5 V | 20.26% |
How Many FreeVolt ECP-PVGRAF-72BHC-395W Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on FreeVolt ECP-PVGRAF-72BHC-395W (53.15 V at 14 F). Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.42 V | 11 panels | 598.6 V | 18 panels |
| -10 C (14 F) | 53.15 V | 11 panels | 584.6 V | 18 panels |
| 0 C (32 F) | 51.88 V | 11 panels | 570.7 V | 19 panels |
| 25 C (77 F STC) | 48.7 V | 12 panels | 584.4 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-72BHC-395W?
Competing CEC solar panels closest to FreeVolt ECP-PVGRAF-72BHC-395W in nameplate wattage and Voc, starting with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
395.0 W | Tie (0 W) | 48.7 V | 20.26% | 92.9% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-395W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
395.0 W | Tie (0 W) | 48.7 V | 20.68% | 92.5% |
| Dehui Solar Power (Vietnam) CoLtd DH-M872F 395W Dehui Solar Power (Vietnam) CoLtd |
395.0 W | Tie (0 W) | 48.7 V | 20.26% | 92.9% |
| Dehui Solar Power (Vietnam) CoLtd DH-M872W 395W Dehui Solar Power (Vietnam) CoLtd |
395.0 W | Tie (0 W) | 48.7 V | 20.68% | 92.5% |
What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-72BHC-395W?
Evaluate FreeVolt ECP-PVGRAF-72BHC-395W (395.0 W STC, 48.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-72BHC-395W reaches 54.42 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 441 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (441 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-72BHC-395W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
FreeVolt ECP-PVGRAF-72BHC-395W 8 kW Residential Fit
Needs 21 modules (441 sq ft) with a 20 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 367.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for FreeVolt ECP-PVGRAF-72BHC-395W by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What fuse or breaker size does NEC 690.8 require for FreeVolt ECP-PVGRAF-72BHC-395W?
Multiplying FreeVolt ECP-PVGRAF-72BHC-395W's 10.29 A short-circuit current by 1.56 equals 16.05 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for FreeVolt ECP-PVGRAF-72BHC-395W before finalizing component orders.
Can FreeVolt ECP-PVGRAF-72BHC-395W pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.15 V cold Voc at 14 F and handles 10.29 A Isc; string inverters cap FreeVolt ECP-PVGRAF-72BHC-395W at 11 panels on 600 V.
Is FreeVolt ECP-PVGRAF-72BHC-395W eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of FreeVolt ECP-PVGRAF-72BHC-395W rely on utility bill offset (~$2,075/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)