FreeVolt ECP-PVGRAF-72BHC-395W — CEC Solar Module Specifications

Manufacturer: FreeVolt Registry: CEC Verified Engineering Specification

FreeVolt ECP-PVGRAF-72BHC-395W is a 395.0 W STC (367.1 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.26% efficiency, 48.7 V Voc at 25 C, and 53.15 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
395.0 W
PTC Wattage
367.1 W
Voc @ 25C
48.7 V
Efficiency
20.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does FreeVolt ECP-PVGRAF-72BHC-395W Compare Against Peer CEC Listings?

Solar engineering breakdown for FreeVolt ECP-PVGRAF-72BHC-395W: PTC thermal retention, roof footprint, and cold Voc string bounds. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Across 5,889 Mono-c-Si listings from FreeVolt and peers, FreeVolt ECP-PVGRAF-72BHC-395W stands 15.0 W below the 410.0 W Mono-c-Si median and strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677). Sizing 6 kW (16 panels) to 10 kW (26 panels) yields $1,582-$2,570/yr in baseline US bill offset. Higher 48.7 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does FreeVolt ECP-PVGRAF-72BHC-395W Fall Across Listed CEC Models?

Distribution marker showing FreeVolt ECP-PVGRAF-72BHC-395W (395.0 W) relative to the 385.0 W all-CEC solar panel median. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where FreeVolt ECP-PVGRAF-72BHC-395W (395.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFreeVolt ECP-PVGRA: 395.0 W

What Dataset Percentiles Define FreeVolt ECP-PVGRAF-72BHC-395W?

Dataset percentiles tracking FreeVolt ECP-PVGRAF-72BHC-395W power output, thermal retention ratio, and aperture efficiency against 21,677 models. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

FreeVolt ECP-PVGRAF-72BHC-395W Engineering BenchmarksPercentile comparison of FreeVolt ECP-PVGRAF-72BHC-395W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage395.0 WPTC/STC Retention92.9%Module Efficiency20.26%

What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-72BHC-395W?

Benchmark highlights for FreeVolt ECP-PVGRAF-72BHC-395W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #9,869 / 21,677

Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,479

20.26% Aperture Efficiency

Power density 202.6 W/m2 (0.35 percentage points above 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.15 V at -10 C (584.6 V string) and 54.42 V at -20 C (11 max).

8 kW Reference Array

21 Panels = 8,295 W STC

Occupies 40.9 m2 (441 sq ft) producing 7,709 W PTC; NEC 690.8 OCPD floor is 16.05 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.7 * (1 + (-0.261/100) * (-10 - 25)) = 53.15 V | OCPD = 1.56 * 10.29 = 16.05 A

Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-72BHC-395W: Voc=48.7 V, beta_Voc=-0.261%/C, Isc=10.29 A, STC=395.0 W, Area=1.95 m2.

Result: 11 panels max on 600 V (584.6 V); 21 panels for 8 kW (441 sq ft).

What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-72BHC-395W?

Official CEC datasheet figures for FreeVolt ECP-PVGRAF-72BHC-395W (Mono-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for FreeVolt ECP-PVGRAF-72BHC-395W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 395.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 367.1 W (92.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.29 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.5 V / 9.76 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.261 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.26% (1.95 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many FreeVolt ECP-PVGRAF-72BHC-395W Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many FreeVolt ECP-PVGRAF-72BHC-395W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.32 kW 336 sq ft $1,582 $2,675
8 kW Class 21 8.29 kW 441 sq ft $2,075 $3,509
10 kW Class 26 10.27 kW 546 sq ft $2,570 $4,347

Which Sibling Wattage & Trim Variants Belong to This FreeVolt Series?

Consolidated FreeVolt wattage variants sharing the FreeVolt ECP-PVGRAF-72BHC-395W mechanical and cell layout. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the FreeVolt ECP-PVGRAF-72BHC-395W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
FreeVolt ECP-PVGRAF-72BHC-390W 390.0 W 362.3 W 48.5 V 40.2 V 20.0%
FreeVolt ECP-PVGRAF-72BHC-395W 395.0 W 367.1 W 48.7 V 40.5 V 20.26%

How Many FreeVolt ECP-PVGRAF-72BHC-395W Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on FreeVolt ECP-PVGRAF-72BHC-395W (53.15 V at 14 F). Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Computed from Voc=48.7V and beta_Voc=-0.261%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.42 V 11 panels 598.6 V 18 panels
-10 C (14 F) 53.15 V 11 panels 584.6 V 18 panels
0 C (32 F) 51.88 V 11 panels 570.7 V 19 panels
25 C (77 F STC) 48.7 V 12 panels 584.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-72BHC-395W?

Competing CEC solar panels closest to FreeVolt ECP-PVGRAF-72BHC-395W in nameplate wattage and Voc, starting with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
395.0 W Tie (0 W) 48.7 V 20.26% 92.9%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-395W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
395.0 W Tie (0 W) 48.7 V 20.68% 92.5%
Dehui Solar Power (Vietnam) CoLtd DH-M872F 395W
Dehui Solar Power (Vietnam) CoLtd
395.0 W Tie (0 W) 48.7 V 20.26% 92.9%
Dehui Solar Power (Vietnam) CoLtd DH-M872W 395W
Dehui Solar Power (Vietnam) CoLtd
395.0 W Tie (0 W) 48.7 V 20.68% 92.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-72BHC-395W?

Evaluate FreeVolt ECP-PVGRAF-72BHC-395W (395.0 W STC, 48.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-72BHC-395W reaches 54.42 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 441 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (441 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-72BHC-395W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

FreeVolt ECP-PVGRAF-72BHC-395W 8 kW Residential Fit

Needs 21 modules (441 sq ft) with a 20 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 367.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for FreeVolt ECP-PVGRAF-72BHC-395W by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

What fuse or breaker size does NEC 690.8 require for FreeVolt ECP-PVGRAF-72BHC-395W?

Multiplying FreeVolt ECP-PVGRAF-72BHC-395W's 10.29 A short-circuit current by 1.56 equals 16.05 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for FreeVolt ECP-PVGRAF-72BHC-395W before finalizing component orders.

Can FreeVolt ECP-PVGRAF-72BHC-395W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.15 V cold Voc at 14 F and handles 10.29 A Isc; string inverters cap FreeVolt ECP-PVGRAF-72BHC-395W at 11 panels on 600 V.

Is FreeVolt ECP-PVGRAF-72BHC-395W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of FreeVolt ECP-PVGRAF-72BHC-395W rely on utility bill offset (~$2,075/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.