FreeVolt ECP-PVGRAF-120HC-375W is a 375.0 W STC (346.5 W PTC) Mono-c-Si solar module ranking #11,367 of 21,677 CEC listings (below all-CEC median; higher than 46.0% of peers). It delivers 20.72% efficiency, 41.1 V Voc at 25 C, and 45.11 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 375.0 W
- PTC Wattage
- 346.5 W
- Voc @ 25C
- 41.1 V
- Efficiency
- 20.72%
How Does FreeVolt ECP-PVGRAF-120HC-375W Compare Against Peer CEC Listings?
How FreeVolt FreeVolt ECP-PVGRAF-120HC-375W handles rooftop heat (346.5 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, FreeVolt ECP-PVGRAF-120HC-375W exhibits 11.6 A short-circuit current, requiring a 18.1 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #11,367 of 21,677 (35.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 39.8 m2 for an 8 kW system (27 panels for 10 kW). Mid-range 41.1 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does FreeVolt ECP-PVGRAF-120HC-375W Fall Across Listed CEC Models?
Where FreeVolt ECP-PVGRAF-120HC-375W (375.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define FreeVolt ECP-PVGRAF-120HC-375W?
Percentile placement of FreeVolt ECP-PVGRAF-120HC-375W across power density (207.2 W/m2), thermal retention, and nameplate STC wattage. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-120HC-375W?
Four critical engineering numbers homeowners and solar installers check first when reviewing FreeVolt ECP-PVGRAF-120HC-375W specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
375.0 W STC · Higher Than 46.0%
375.0 W STC (-10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.72% Aperture Efficiency
Power density 207.2 W/m2 (0.81 percentage points above 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.11 V at -10 C (586.4 V string) and 46.26 V at -20 C (12 max).
22 Panels = 8,250 W STC
Occupies 39.8 m2 (429 sq ft) producing 7,623 W PTC; NEC 690.8 OCPD floor is 18.1 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.1 * (1 + (-0.279/100) * (-10 - 25)) = 45.11 V | OCPD = 1.56 * 11.6 = 18.1 A
Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-120HC-375W: Voc=41.1 V, beta_Voc=-0.279%/C, Isc=11.6 A, STC=375.0 W, Area=1.81 m2.
Result: 13 panels max on 600 V (586.4 V); 22 panels for 8 kW (429 sq ft).
What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-120HC-375W?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for FreeVolt ECP-PVGRAF-120HC-375W. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 375.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 346.5 W (92.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.6 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.6 V / 10.84 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.279 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.72% (1.81 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many FreeVolt ECP-PVGRAF-120HC-375W Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using FreeVolt ECP-PVGRAF-120HC-375W (375.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.0 kW | 312 sq ft | $1,502 | $2,539 |
| 8 kW Class | 22 | 8.25 kW | 429 sq ft | $2,065 | $3,492 |
| 10 kW Class | 27 | 10.12 kW | 526 sq ft | $2,533 | $4,283 |
How Many FreeVolt ECP-PVGRAF-120HC-375W Modules Fit in a Cold-Weather String?
Maximum series module counts for FreeVolt ECP-PVGRAF-120HC-375W from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.26 V | 12 panels | 555.1 V | 21 panels |
| -10 C (14 F) | 45.11 V | 13 panels | 586.4 V | 22 panels |
| 0 C (32 F) | 43.97 V | 13 panels | 571.6 V | 22 panels |
| 25 C (77 F STC) | 41.1 V | 14 panels | 575.4 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-120HC-375W?
Alternative CEC solar modules from competing brands near FreeVolt ECP-PVGRAF-120HC-375W (375.0 W), including Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
375.0 W | Tie (0 W) | 41.1 V | 21.07% | 92.6% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
375.0 W | Tie (0 W) | 41.1 V | 20.72% | 92.4% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W Black Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
375.0 W | Tie (0 W) | 41.1 V | 20.49% | 93.4% |
| AXITEC AC-375MH/120V AXITEC |
375.0 W | Tie (0 W) | 41.1 V | 20.72% | 92.4% |
What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-120HC-375W?
Evaluate FreeVolt ECP-PVGRAF-120HC-375W (375.0 W STC, 41.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-120HC-375W reaches 46.26 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 429 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (429 sq ft).
- 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-120HC-375W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
FreeVolt ECP-PVGRAF-120HC-375W 8 kW Residential Fit
Needs 22 modules (429 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 346.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for FreeVolt ECP-PVGRAF-120HC-375W by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
Why is FreeVolt ECP-PVGRAF-120HC-375W PTC wattage (346.5 W) lower than STC (375.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 346.5 W PTC (92.4% retention) across FreeVolt ECP-PVGRAF-120HC-375W's 1.81 m2 aperture.
Who should skip FreeVolt ECP-PVGRAF-120HC-375W on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 FreeVolt ECP-PVGRAF-120HC-375W panels (429 sq ft) leave unusable roof gaps vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W.
What is the 1,000 V commercial string limit for FreeVolt ECP-PVGRAF-120HC-375W?
On 1,000 V commercial inverters at -10 C (45.11 V cold Voc), FreeVolt ECP-PVGRAF-120HC-375W fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting FreeVolt ECP-PVGRAF-120HC-375W.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)