FreeVolt ECP-PVGRAF-120HC-375W Black is a 375.0 W STC (350.3 W PTC) Mono-c-Si solar module ranking #11,367 of 21,677 CEC listings (below all-CEC median; higher than 46.0% of peers). It delivers 20.49% efficiency, 41.1 V Voc at 25 C, and 45.14 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 375.0 W
- PTC Wattage
- 350.3 W
- Voc @ 25C
- 41.1 V
- Efficiency
- 20.49%
How Does FreeVolt ECP-PVGRAF-120HC-375W Black Compare Against Peer CEC Listings?
Solar engineering breakdown for FreeVolt ECP-PVGRAF-120HC-375W Black: PTC thermal retention, roof footprint, and cold Voc string bounds. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
Across 5,889 Mono-c-Si listings from FreeVolt and peers, FreeVolt ECP-PVGRAF-120HC-375W Black stands 35.0 W below the 410.0 W Mono-c-Si median and strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677). Sizing 6 kW (16 panels) to 10 kW (27 panels) yields $1,502-$2,533/yr in baseline US bill offset. Mid-range 41.1 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does FreeVolt ECP-PVGRAF-120HC-375W Black Fall Across Listed CEC Models?
Distribution marker showing FreeVolt ECP-PVGRAF-120HC-375W Black (375.0 W) relative to the 385.0 W all-CEC solar panel median. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Dataset Percentiles Define FreeVolt ECP-PVGRAF-120HC-375W Black?
Dataset percentiles tracking FreeVolt ECP-PVGRAF-120HC-375W Black power output, thermal retention ratio, and aperture efficiency against 21,677 models. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-120HC-375W Black?
Benchmark highlights for FreeVolt ECP-PVGRAF-120HC-375W Black covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
375.0 W STC · Higher Than 46.0%
375.0 W STC (-10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.49% Aperture Efficiency
Power density 204.9 W/m2 (0.58 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.14 V at -10 C (586.8 V string) and 46.3 V at -20 C (12 max).
22 Panels = 8,250 W STC
Occupies 40.3 m2 (433 sq ft) producing 7,707 W PTC; NEC 690.8 OCPD floor is 18.1 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.1 * (1 + (-0.281/100) * (-10 - 25)) = 45.14 V | OCPD = 1.56 * 11.6 = 18.1 A
Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-120HC-375W Black: Voc=41.1 V, beta_Voc=-0.281%/C, Isc=11.6 A, STC=375.0 W, Area=1.83 m2.
Result: 13 panels max on 600 V (586.8 V); 22 panels for 8 kW (433 sq ft).
What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-120HC-375W Black?
Official CEC datasheet figures for FreeVolt ECP-PVGRAF-120HC-375W Black (Mono-c-Si) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 375.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 350.3 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.6 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.6 V / 10.84 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.281 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.49% (1.83 m2) | Array roof footprint density |
| Cell Count & Technology | 40 cells (Mono-c-Si) | Monofacial backsheet |
How Many FreeVolt ECP-PVGRAF-120HC-375W Black Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many FreeVolt ECP-PVGRAF-120HC-375W Black modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.0 kW | 315 sq ft | $1,502 | $2,539 |
| 8 kW Class | 22 | 8.25 kW | 433 sq ft | $2,065 | $3,492 |
| 10 kW Class | 27 | 10.12 kW | 532 sq ft | $2,533 | $4,283 |
How Many FreeVolt ECP-PVGRAF-120HC-375W Black Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on FreeVolt ECP-PVGRAF-120HC-375W Black (45.14 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.3 V | 12 panels | 555.6 V | 21 panels |
| -10 C (14 F) | 45.14 V | 13 panels | 586.8 V | 22 panels |
| 0 C (32 F) | 43.99 V | 13 panels | 571.9 V | 22 panels |
| 25 C (77 F STC) | 41.1 V | 14 panels | 575.4 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-120HC-375W Black?
Competing CEC solar panels closest to FreeVolt ECP-PVGRAF-120HC-375W Black in nameplate wattage and Voc, starting with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
375.0 W | Tie (0 W) | 41.1 V | 21.07% | 92.6% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
375.0 W | Tie (0 W) | 41.1 V | 20.72% | 92.4% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W Black Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
375.0 W | Tie (0 W) | 41.1 V | 20.49% | 93.4% |
| AXITEC AC-375MH/120V AXITEC |
375.0 W | Tie (0 W) | 41.1 V | 20.72% | 92.4% |
What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-120HC-375W Black?
Evaluate FreeVolt ECP-PVGRAF-120HC-375W Black (375.0 W STC, 41.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-120HC-375W Black reaches 46.3 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 433 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (433 sq ft).
- 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-120HC-375W Black carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
FreeVolt ECP-PVGRAF-120HC-375W Black 8 kW Residential Fit
Needs 22 modules (433 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 350.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for FreeVolt ECP-PVGRAF-120HC-375W Black by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for FreeVolt ECP-PVGRAF-120HC-375W Black?
Multiplying FreeVolt ECP-PVGRAF-120HC-375W Black's 11.6 A short-circuit current by 1.56 equals 18.1 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can FreeVolt ECP-PVGRAF-120HC-375W Black pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 45.14 V cold Voc at 14 F and handles 11.6 A Isc; string inverters cap FreeVolt ECP-PVGRAF-120HC-375W Black at 13 panels on 600 V.
Is FreeVolt ECP-PVGRAF-120HC-375W Black eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of FreeVolt ECP-PVGRAF-120HC-375W Black rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)