Skip to main content
WireAndSun
Calculators
CEC PV Module

FreeVolt ECP-PVGRAF-120BHC-375W — CEC Solar Module Specifications

Manufacturer: FreeVolt Registry: CEC Verified Engineering Specification

FreeVolt ECP-PVGRAF-120BHC-375W is a 375.0 W STC (347.4 W PTC) Mono-c-Si solar module ranking #11,367 of 21,677 CEC listings (below all-CEC median; higher than 46.0% of peers). It delivers 21.07% efficiency, 41.1 V Voc at 25 C, and 45.59 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
375.0 W
PTC Wattage
347.4 W
Voc @ 25C
41.1 V
Efficiency
21.07%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does FreeVolt ECP-PVGRAF-120BHC-375W Compare Against Peer CEC Listings?

Solar engineering breakdown for FreeVolt ECP-PVGRAF-120BHC-375W: PTC thermal retention, roof footprint, and cold Voc string bounds. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Across 5,889 Mono-c-Si listings from FreeVolt and peers, FreeVolt ECP-PVGRAF-120BHC-375W stands 35.0 W below the 410.0 W Mono-c-Si median and strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677). Sizing 6 kW (16 panels) to 10 kW (27 panels) yields $1,502-$2,533/yr in baseline US bill offset. Mid-range 41.1 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

Where Does FreeVolt ECP-PVGRAF-120BHC-375W Fall Across Listed CEC Models?

Distribution marker showing FreeVolt ECP-PVGRAF-120BHC-375W (375.0 W) relative to the 385.0 W all-CEC solar panel median. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where FreeVolt ECP-PVGRAF-120BHC-375W (375.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFreeVolt ECP-PVGRA: 375.0 W

What Dataset Percentiles Define FreeVolt ECP-PVGRAF-120BHC-375W?

Dataset percentiles tracking FreeVolt ECP-PVGRAF-120BHC-375W power output, thermal retention ratio, and aperture efficiency against 21,677 models. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

FreeVolt ECP-PVGRAF-120BHC-375W Engineering BenchmarksPercentile comparison of FreeVolt ECP-PVGRAF-120BHC-375W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage375.0 WPTC/STC Retention92.6%Module Efficiency21.07%

What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-120BHC-375W?

Benchmark highlights for FreeVolt ECP-PVGRAF-120BHC-375W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #11,367 / 21,677

375.0 W STC · Higher Than 46.0%

375.0 W STC (-10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,087

21.07% Aperture Efficiency

Power density 210.7 W/m2 (1.16 percentage points above 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.59 V at -10 C (592.7 V string) and 46.87 V at -20 C (12 max).

8 kW Reference Array

22 Panels = 8,250 W STC

Occupies 39.2 m2 (422 sq ft) producing 7,643 W PTC; NEC 690.8 OCPD floor is 18.08 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.1 * (1 + (-0.312/100) * (-10 - 25)) = 45.59 V | OCPD = 1.56 * 11.59 = 18.08 A

Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-120BHC-375W: Voc=41.1 V, beta_Voc=-0.312%/C, Isc=11.59 A, STC=375.0 W, Area=1.78 m2.

Result: 13 panels max on 600 V (592.7 V); 22 panels for 8 kW (422 sq ft).

What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-120BHC-375W?

Official CEC datasheet figures for FreeVolt ECP-PVGRAF-120BHC-375W (Mono-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Official California Energy Commission (NREL SAM) test parameters for FreeVolt ECP-PVGRAF-120BHC-375W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 375.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 347.4 W (92.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.59 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.5 V / 10.87 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.312 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.07% (1.78 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many FreeVolt ECP-PVGRAF-120BHC-375W Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many FreeVolt ECP-PVGRAF-120BHC-375W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.0 kW 307 sq ft $1,502 $2,539
8 kW Class 22 8.25 kW 422 sq ft $2,065 $3,492
10 kW Class 27 10.12 kW 517 sq ft $2,533 $4,283

How Many FreeVolt ECP-PVGRAF-120BHC-375W Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on FreeVolt ECP-PVGRAF-120BHC-375W (45.59 V at 14 F). Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Computed from Voc=41.1V and beta_Voc=-0.312%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.87 V 12 panels 562.4 V 21 panels
-10 C (14 F) 45.59 V 13 panels 592.7 V 21 panels
0 C (32 F) 44.31 V 13 panels 576.0 V 22 panels
25 C (77 F STC) 41.1 V 14 panels 575.4 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-120BHC-375W?

Competing CEC solar panels closest to FreeVolt ECP-PVGRAF-120BHC-375W in nameplate wattage and Voc, starting with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
375.0 W Tie (0 W) 41.1 V 21.07% 92.6%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
375.0 W Tie (0 W) 41.1 V 20.72% 92.4%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W Black
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
375.0 W Tie (0 W) 41.1 V 20.49% 93.4%
AXITEC AC-375MH/120V
AXITEC
375.0 W Tie (0 W) 41.1 V 20.72% 92.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-120BHC-375W?

Evaluate FreeVolt ECP-PVGRAF-120BHC-375W (375.0 W STC, 41.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-120BHC-375W reaches 46.87 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 422 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (422 sq ft).
  • 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-120BHC-375W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

FreeVolt ECP-PVGRAF-120BHC-375W 8 kW Residential Fit

Needs 22 modules (422 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 347.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for FreeVolt ECP-PVGRAF-120BHC-375W by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

What fuse or breaker size does NEC 690.8 require for FreeVolt ECP-PVGRAF-120BHC-375W?

Multiplying FreeVolt ECP-PVGRAF-120BHC-375W's 11.59 A short-circuit current by 1.56 equals 18.08 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for FreeVolt ECP-PVGRAF-120BHC-375W before finalizing component orders.

Can FreeVolt ECP-PVGRAF-120BHC-375W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 45.59 V cold Voc at 14 F and handles 11.59 A Isc; string inverters cap FreeVolt ECP-PVGRAF-120BHC-375W at 13 panels on 600 V.

Is FreeVolt ECP-PVGRAF-120BHC-375W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of FreeVolt ECP-PVGRAF-120BHC-375W rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.