FreeVolt ECP-PVGRAF-120BHC-375W is a 375.0 W STC (347.4 W PTC) Mono-c-Si solar module ranking #11,367 of 21,677 CEC listings (below all-CEC median; higher than 46.0% of peers). It delivers 21.07% efficiency, 41.1 V Voc at 25 C, and 45.59 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 375.0 W
- PTC Wattage
- 347.4 W
- Voc @ 25C
- 41.1 V
- Efficiency
- 21.07%
How Does FreeVolt ECP-PVGRAF-120BHC-375W Compare Against Peer CEC Listings?
Solar engineering breakdown for FreeVolt ECP-PVGRAF-120BHC-375W: PTC thermal retention, roof footprint, and cold Voc string bounds. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
Across 5,889 Mono-c-Si listings from FreeVolt and peers, FreeVolt ECP-PVGRAF-120BHC-375W stands 35.0 W below the 410.0 W Mono-c-Si median and strong 92.6% PTC-to-STC heat retention (#11,981 of 21,677). Sizing 6 kW (16 panels) to 10 kW (27 panels) yields $1,502-$2,533/yr in baseline US bill offset. Mid-range 41.1 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does FreeVolt ECP-PVGRAF-120BHC-375W Fall Across Listed CEC Models?
Distribution marker showing FreeVolt ECP-PVGRAF-120BHC-375W (375.0 W) relative to the 385.0 W all-CEC solar panel median. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Dataset Percentiles Define FreeVolt ECP-PVGRAF-120BHC-375W?
Dataset percentiles tracking FreeVolt ECP-PVGRAF-120BHC-375W power output, thermal retention ratio, and aperture efficiency against 21,677 models. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
What Do the Dataset Ranks Show for FreeVolt ECP-PVGRAF-120BHC-375W?
Benchmark highlights for FreeVolt ECP-PVGRAF-120BHC-375W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
375.0 W STC · Higher Than 46.0%
375.0 W STC (-10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.07% Aperture Efficiency
Power density 210.7 W/m2 (1.16 percentage points above 19.91% CEC median). PTC/STC ratio: 92.6% (rank #11,981).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.59 V at -10 C (592.7 V string) and 46.87 V at -20 C (12 max).
22 Panels = 8,250 W STC
Occupies 39.2 m2 (422 sq ft) producing 7,643 W PTC; NEC 690.8 OCPD floor is 18.08 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.1 * (1 + (-0.312/100) * (-10 - 25)) = 45.59 V | OCPD = 1.56 * 11.59 = 18.08 A
Inputs from CEC Modules.csv for FreeVolt ECP-PVGRAF-120BHC-375W: Voc=41.1 V, beta_Voc=-0.312%/C, Isc=11.59 A, STC=375.0 W, Area=1.78 m2.
Result: 13 panels max on 600 V (592.7 V); 22 panels for 8 kW (422 sq ft).
What Are the Published CEC Specifications for FreeVolt ECP-PVGRAF-120BHC-375W?
Official CEC datasheet figures for FreeVolt ECP-PVGRAF-120BHC-375W (Mono-c-Si) used in utility interconnection and permit reviews. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 375.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 347.4 W (92.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.59 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.5 V / 10.87 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.312 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.07% (1.78 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many FreeVolt ECP-PVGRAF-120BHC-375W Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many FreeVolt ECP-PVGRAF-120BHC-375W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.0 kW | 307 sq ft | $1,502 | $2,539 |
| 8 kW Class | 22 | 8.25 kW | 422 sq ft | $2,065 | $3,492 |
| 10 kW Class | 27 | 10.12 kW | 517 sq ft | $2,533 | $4,283 |
How Many FreeVolt ECP-PVGRAF-120BHC-375W Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on FreeVolt ECP-PVGRAF-120BHC-375W (45.59 V at 14 F). Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.87 V | 12 panels | 562.4 V | 21 panels |
| -10 C (14 F) | 45.59 V | 13 panels | 592.7 V | 21 panels |
| 0 C (32 F) | 44.31 V | 13 panels | 576.0 V | 22 panels |
| 25 C (77 F STC) | 41.1 V | 14 panels | 575.4 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to FreeVolt ECP-PVGRAF-120BHC-375W?
Competing CEC solar panels closest to FreeVolt ECP-PVGRAF-120BHC-375W in nameplate wattage and Voc, starting with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
375.0 W | Tie (0 W) | 41.1 V | 21.07% | 92.6% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
375.0 W | Tie (0 W) | 41.1 V | 20.72% | 92.4% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-HC-375W Black Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
375.0 W | Tie (0 W) | 41.1 V | 20.49% | 93.4% |
| AXITEC AC-375MH/120V AXITEC |
375.0 W | Tie (0 W) | 41.1 V | 20.72% | 92.4% |
What Are the Design Limits and Best-Fit Uses for FreeVolt ECP-PVGRAF-120BHC-375W?
Evaluate FreeVolt ECP-PVGRAF-120BHC-375W (375.0 W STC, 41.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), FreeVolt ECP-PVGRAF-120BHC-375W reaches 46.87 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 422 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (422 sq ft).
- 2026 tax credit baseline: cash residential installs of FreeVolt ECP-PVGRAF-120BHC-375W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
FreeVolt ECP-PVGRAF-120BHC-375W 8 kW Residential Fit
Needs 22 modules (422 sq ft) with a 20 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M120-BHC-375W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 347.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for FreeVolt ECP-PVGRAF-120BHC-375W by FreeVolt grounded in CEC test data and NEC 690.7/690.8 limits. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
What fuse or breaker size does NEC 690.8 require for FreeVolt ECP-PVGRAF-120BHC-375W?
Multiplying FreeVolt ECP-PVGRAF-120BHC-375W's 11.59 A short-circuit current by 1.56 equals 18.08 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for FreeVolt ECP-PVGRAF-120BHC-375W before finalizing component orders.
Can FreeVolt ECP-PVGRAF-120BHC-375W pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 45.59 V cold Voc at 14 F and handles 11.59 A Isc; string inverters cap FreeVolt ECP-PVGRAF-120BHC-375W at 13 panels on 600 V.
Is FreeVolt ECP-PVGRAF-120BHC-375W eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of FreeVolt ECP-PVGRAF-120BHC-375W rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)