Applied Materials 1/4 Size Tandem Junction is a 114.0 W STC (104.6 W PTC) Thin Film solar module ranking #21,518 of 21,677 CEC listings (below all-CEC median; higher than 0.7% of peers). It delivers 7.97% efficiency, 137.6 V Voc at 25 C, and 156.91 V cold Voc at -10 C (3 panels max per 600 V string).
- STC Wattage
- 114.0 W
- PTC Wattage
- 104.6 W
- Voc @ 25C
- 137.6 V
- Efficiency
- 7.97%
How Does Applied Materials 1/4 Size Tandem Junction Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Applied Materials 1/4 Size Tandem Junction (Thin Film) residential solar systems.
Homeowners evaluating Applied Materials 1/4 Size Tandem Junction need 53 panels for 6 kW or 71 panels (1,093 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 71 panels (1,093 sq ft). Under NEC 690.7(A), beta_Voc (-0.401%/C) pushes open-circuit voltage to 156.91 V at 14 F and 162.43 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Applied Materials 1/4 Size Tandem Junction Fall Across Listed CEC Models?
Comparison of Applied Materials 1/4 Size Tandem Junction (114.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Applied Materials 1/4 Size Tandem Junction?
Relative ranking of Applied Materials 1/4 Size Tandem Junction across nameplate watts, 91.8% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Applied Materials 1/4 Size Tandem Junction?
Summary of Applied Materials 1/4 Size Tandem Junction output rank, 8 kW array size (71 panels), efficiency rating, and 600 V string limit.
114.0 W STC · Higher Than 0.7%
114.0 W STC (-271.0 W vs all-CEC median) vs 117.5 W Thin Film median.
7.97% Aperture Efficiency
Power density 79.7 W/m2 (11.94 percentage points below 19.91% CEC median). PTC/STC ratio: 91.8% (rank #14,745).
3 Panels Max @ -10 C (600 V)
Cold Voc reaches 156.91 V at -10 C (470.7 V string) and 162.43 V at -20 C (3 max).
71 Panels = 8,094 W STC
Occupies 101.5 m2 (1,093 sq ft) producing 7,427 W PTC; NEC 690.8 OCPD floor is 2.03 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 137.6 * (1 + (-0.401/100) * (-10 - 25)) = 156.91 V | OCPD = 1.56 * 1.3 = 2.03 A
Inputs from CEC Modules.csv for Applied Materials 1/4 Size Tandem Junction: Voc=137.6 V, beta_Voc=-0.401%/C, Isc=1.3 A, STC=114.0 W, Area=1.43 m2.
Result: 3 panels max on 600 V (470.7 V); 71 panels for 8 kW (1,093 sq ft).
What Are the Published CEC Specifications for Applied Materials 1/4 Size Tandem Junction?
Complete CEC test sheet for Applied Materials 1/4 Size Tandem Junction including Isc (1.3 A), Voc (137.6 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 114.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 104.6 W (91.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 137.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 1.3 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 106.0 V / 1.08 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.401 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 7.97% (1.43 m2) | Array roof footprint density |
| Cell Count & Technology | 106 cells (Thin Film) | Monofacial backsheet |
How Many Applied Materials 1/4 Size Tandem Junction Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Applied Materials 1/4 Size Tandem Junction.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 53 | 6.04 kW | 816 sq ft | $1,512 | $2,556 |
| 8 kW Class | 71 | 8.09 kW | 1,093 sq ft | $2,025 | $3,424 |
| 10 kW Class | 88 | 10.03 kW | 1,355 sq ft | $2,510 | $4,245 |
How Many Applied Materials 1/4 Size Tandem Junction Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Applied Materials 1/4 Size Tandem Junction (137.6 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 162.43 V | 3 panels | 487.3 V | 6 panels |
| -10 C (14 F) | 156.91 V | 3 panels | 470.7 V | 6 panels |
| 0 C (32 F) | 151.39 V | 3 panels | 454.2 V | 6 panels |
| 25 C (77 F STC) | 137.6 V | 4 panels | 550.4 V | 7 panels |
Which Cross-Brand Solar Modules Compare Closest to Applied Materials 1/4 Size Tandem Junction?
Four comparable CEC modules such as Zhongshan Ruike New Energy Co Ltd RK-105 (105.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Zhongshan Ruike New Energy Co Ltd RK-105 Zhongshan Ruike New Energy Co Ltd |
105.0 W | -9.0 W | 120.1 V | 14.58% | 93.0% |
| Du Pont Apollo DA133-C2 Du Pont Apollo |
133.0 W | +19.0 W | 156.73 V | 8.64% | 92.0% |
| Zhongshan Ruike New Energy Co Ltd RK-95 Zhongshan Ruike New Energy Co Ltd |
95.0 W | -19.0 W | 116.4 V | 13.19% | 92.8% |
| Advanced Solar Power (Hangzhou) ASP-S1-80 Advanced Solar Power (Hangzhou) |
80.0 W | -34.0 W | 118.9 V | 11.11% | 94.0% |
What Are the Design Limits and Best-Fit Uses for Applied Materials 1/4 Size Tandem Junction?
Evaluate Applied Materials 1/4 Size Tandem Junction (114.0 W STC, 137.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Applied Materials 1/4 Size Tandem Junction reaches 162.43 V per panel—exceeding 3 panels in series voids 600 V inverter warranties.
- Footprint constraint: 71 panels for an 8 kW build require 1,093 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 71 panels (1,093 sq ft).
- 2026 tax credit baseline: cash residential installs of Applied Materials 1/4 Size Tandem Junction carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Applied Materials 1/4 Size Tandem Junction 8 kW Residential Fit
Needs 71 modules (1,093 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 3 panels (-10 C) or 3 panels (-20 C), or compare Zhongshan Ruike New Energy Co Ltd RK-105.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 104.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Applied Materials 1/4 Size Tandem Junction by Applied Materials grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Applied Materials 1/4 Size Tandem Junction PTC wattage (104.6 W) lower than STC (114.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 104.6 W PTC (91.8% retention) across Applied Materials 1/4 Size Tandem Junction's 1.43 m2 aperture.
Who should skip Applied Materials 1/4 Size Tandem Junction on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 71 Applied Materials 1/4 Size Tandem Junction panels (1,093 sq ft) leave unusable roof gaps vs. Zhongshan Ruike New Energy Co Ltd RK-105.
What is the 1,000 V commercial string limit for Applied Materials 1/4 Size Tandem Junction?
On 1,000 V commercial inverters at -10 C (156.91 V cold Voc), Applied Materials 1/4 Size Tandem Junction fits up to 6 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)