Du Pont Apollo DA133-C2 is a 133.0 W STC (122.4 W PTC) Thin Film solar module ranking #21,471 of 21,677 CEC listings (below all-CEC median; higher than 1.0% of peers). It delivers 8.64% efficiency, 156.73 V Voc at 25 C, and 173.74 V cold Voc at -10 C (3 panels max per 600 V string).
- STC Wattage
- 133.0 W
- PTC Wattage
- 122.4 W
- Voc @ 25C
- 156.73 V
- Efficiency
- 8.64%
How Does Du Pont Apollo DA133-C2 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Du Pont Apollo DA133-C2 (Thin Film) residential solar systems.
Du Pont Apollo DA133-C2 delivers 86.4 W/m2 (11.27 percentage points below 19.91% CEC median) and strong 92.0% PTC-to-STC heat retention (#14,141 of 21,677), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 61 panels (1,011 sq ft). At -4 F (-20 C), string voltage climbs to 178.59 V per unit, capping 600 V circuits at 3 panels. Compare specs directly with Applied Materials 1/4 Size Tandem Junction (114.0 W).
Where Does Du Pont Apollo DA133-C2 Fall Across Listed CEC Models?
Comparison of Du Pont Apollo DA133-C2 (133.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Du Pont Apollo DA133-C2?
Relative ranking of Du Pont Apollo DA133-C2 across nameplate watts, 92.0% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Du Pont Apollo DA133-C2?
Summary of Du Pont Apollo DA133-C2 output rank, 8 kW array size (61 panels), efficiency rating, and 600 V string limit.
133.0 W STC · Higher Than 1.0%
133.0 W STC (-252.0 W vs all-CEC median) vs 117.5 W Thin Film median.
8.64% Aperture Efficiency
Power density 86.4 W/m2 (11.27 percentage points below 19.91% CEC median). PTC/STC ratio: 92.0% (rank #14,141).
3 Panels Max @ -10 C (600 V)
Cold Voc reaches 173.74 V at -10 C (521.2 V string) and 178.59 V at -20 C (3 max).
61 Panels = 8,113 W STC
Occupies 93.9 m2 (1,011 sq ft) producing 7,466 W PTC; NEC 690.8 OCPD floor is 2.01 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 156.73 * (1 + (-0.31/100) * (-10 - 25)) = 173.74 V | OCPD = 1.56 * 1.29 = 2.01 A
Inputs from CEC Modules.csv for Du Pont Apollo DA133-C2: Voc=156.73 V, beta_Voc=-0.31%/C, Isc=1.29 A, STC=133.0 W, Area=1.54 m2.
Result: 3 panels max on 600 V (521.2 V); 61 panels for 8 kW (1,011 sq ft).
What Are the Published CEC Specifications for Du Pont Apollo DA133-C2?
Complete CEC test sheet for Du Pont Apollo DA133-C2 including Isc (1.29 A), Voc (156.73 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 133.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 122.4 W (92.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 156.73 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 1.29 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 122.13 V / 1.09 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.31 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 8.64% (1.54 m2) | Array roof footprint density |
| Cell Count & Technology | 119 cells (Thin Film) | Monofacial backsheet |
How Many Du Pont Apollo DA133-C2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Du Pont Apollo DA133-C2.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 46 | 6.12 kW | 763 sq ft | $1,532 | $2,590 |
| 8 kW Class | 61 | 8.11 kW | 1,011 sq ft | $2,030 | $3,432 |
| 10 kW Class | 76 | 10.11 kW | 1,260 sq ft | $2,530 | $4,279 |
Which Sibling Wattage & Trim Variants Belong to This Du Pont Apollo Series?
Related Du Pont Apollo power steps and black/silver trims consolidated into this Du Pont Apollo DA133-C2 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Du Pont Apollo DA130-C2 | 130.0 W | 119.6 W | 154.96 V | 120.75 V | 8.44% |
| Du Pont Apollo DA133-C2 | 133.0 W | 122.4 W | 156.73 V | 122.13 V | 8.64% |
| Du Pont Apollo DA136-C2 | 136.0 W | 125.2 W | 158.49 V | 123.5 V | 8.83% |
How Many Du Pont Apollo DA133-C2 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Du Pont Apollo DA133-C2 (156.73 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 178.59 V | 3 panels | 535.8 V | 5 panels |
| -10 C (14 F) | 173.74 V | 3 panels | 521.2 V | 5 panels |
| 0 C (32 F) | 168.88 V | 3 panels | 506.6 V | 5 panels |
| 25 C (77 F STC) | 156.73 V | 3 panels | 470.2 V | 6 panels |
Which Cross-Brand Solar Modules Compare Closest to Du Pont Apollo DA133-C2?
Four comparable CEC modules such as Applied Materials 1/4 Size Tandem Junction (114.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials 1/4 Size Tandem Junction Applied Materials |
114.0 W | -19.0 W | 137.6 V | 7.97% | 91.8% |
| Zhongshan Ruike New Energy Co Ltd RK-105 Zhongshan Ruike New Energy Co Ltd |
105.0 W | -28.0 W | 120.1 V | 14.58% | 93.0% |
| Zhongshan Ruike New Energy Co Ltd RK-95 Zhongshan Ruike New Energy Co Ltd |
95.0 W | -38.0 W | 116.4 V | 13.19% | 92.8% |
| Advanced Solar Power (Hangzhou) ASP-S1-80 Advanced Solar Power (Hangzhou) |
80.0 W | -53.0 W | 118.9 V | 11.11% | 94.0% |
What Are the Design Limits and Best-Fit Uses for Du Pont Apollo DA133-C2?
Evaluate Du Pont Apollo DA133-C2 (133.0 W STC, 156.73 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Du Pont Apollo DA133-C2 reaches 178.59 V per panel—exceeding 3 panels in series voids 600 V inverter warranties.
- Footprint constraint: 61 panels for an 8 kW build require 1,011 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 61 panels (1,011 sq ft).
- 2026 tax credit baseline: cash residential installs of Du Pont Apollo DA133-C2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Du Pont Apollo DA133-C2 8 kW Residential Fit
Needs 61 modules (1,011 sq ft) with a 15 A string OCPD, offsetting ~$2,030/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 3 panels (-10 C) or 3 panels (-20 C), or compare Applied Materials 1/4 Size Tandem Junction.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 122.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Du Pont Apollo DA133-C2 by Du Pont Apollo grounded in CEC test data and NEC 690.7/690.8 limits.
How many Du Pont Apollo DA133-C2 panels fit on a 600 V winter solar string?
At -10 C (14 F), Du Pont Apollo DA133-C2 cold Voc rises from 156.73 V to 173.74 V (beta_Voc -0.31%/C), capping a 600 V string at 3 panels (521.2 V).
How much roof area does an 8 kW array of Du Pont Apollo DA133-C2 need?
An 8 kW DC system uses 61 Du Pont Apollo DA133-C2 modules (8,113 W STC / 7,466 W PTC), covering roughly 1,011 sq ft and saving ~$2,030/yr at 18.54 c/kWh.
How does Du Pont Apollo DA133-C2 compare against Applied Materials 1/4 Size Tandem Junction?
Du Pont Apollo DA133-C2 outputs 133.0 W STC (156.73 V Voc, rank #21,471 of 21,677), while Applied Materials 1/4 Size Tandem Junction delivers 114.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)