Zhongshan Ruike New Energy Co Ltd RK-105 is a 105.0 W STC (97.7 W PTC) CdTe solar module ranking #21,543 of 21,677 CEC listings (below all-CEC median; higher than 0.6% of peers). It delivers 14.58% efficiency, 120.1 V Voc at 25 C, and 133.8 V cold Voc at -10 C (4 panels max per 600 V string).
- STC Wattage
- 105.0 W
- PTC Wattage
- 97.7 W
- Voc @ 25C
- 120.1 V
- Efficiency
- 14.58%
How Does Zhongshan Ruike New Energy Co Ltd RK-105 Compare Against Peer CEC Listings?
Engineering position of Zhongshan Ruike New Energy Co Ltd RK-105 (105.0 W STC) vs. Advanced Solar Power (Hangzhou) ASP-S1-80 across 131 CEC CdTe solar modules.
Ranking #21,543 across 21,677 CEC solar panels (below all-CEC median; higher than 0.6% of peers), Zhongshan Ruike New Energy Co Ltd RK-105 operates as a compact residential or specialty off-grid module sitting 340.0 W below the 445.0 W CdTe median. Higher 120.1 V open-circuit voltage caps 600 V residential strings at 4 panels at 14 F (-10 C). With strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677), 77 panels occupy 597 sq ft and offset roughly $2,025/yr at average US rates (or $3,424/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Zhongshan Ruike New Energy Co Ltd RK-105 Fall Across Listed CEC Models?
Plots Zhongshan Ruike New Energy Co Ltd RK-105 at 105.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Zhongshan Ruike New Energy Co Ltd RK-105?
Benchmarks Zhongshan Ruike New Energy Co Ltd RK-105 on STC wattage, thermal PTC/STC retention, and 14.58 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Zhongshan Ruike New Energy Co Ltd RK-105?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Zhongshan Ruike New Energy Co Ltd RK-105 by Zhongshan Ruike New Energy Co Ltd.
105.0 W STC · Higher Than 0.6%
105.0 W STC (-280.0 W vs all-CEC median) vs 445.0 W CdTe median.
14.58% Aperture Efficiency
Power density 145.8 W/m2 (5.33 percentage points below 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).
4 Panels Max @ -10 C (600 V)
Cold Voc reaches 133.8 V at -10 C (535.2 V string) and 137.72 V at -20 C (4 max).
77 Panels = 8,085 W STC
Occupies 55.4 m2 (597 sq ft) producing 7,523 W PTC; NEC 690.8 OCPD floor is 2.06 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 120.1 * (1 + (-0.326/100) * (-10 - 25)) = 133.8 V | OCPD = 1.56 * 1.32 = 2.06 A
Inputs from CEC Modules.csv for Zhongshan Ruike New Energy Co Ltd RK-105: Voc=120.1 V, beta_Voc=-0.326%/C, Isc=1.32 A, STC=105.0 W, Area=0.72 m2.
Result: 4 panels max on 600 V (535.2 V); 77 panels for 8 kW (597 sq ft).
What Are the Published CEC Specifications for Zhongshan Ruike New Energy Co Ltd RK-105?
Laboratory test ratings recorded for Zhongshan Ruike New Energy Co Ltd RK-105 (CdTe) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 105.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 97.7 W (93.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 120.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 1.32 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 90.6 V / 1.16 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.326 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.58% (0.72 m2) | Array roof footprint density |
| Cell Count & Technology | 146 cells (CdTe) | Monofacial backsheet |
How Many Zhongshan Ruike New Energy Co Ltd RK-105 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (597 sq ft at 8 kW), and estimated Year-1 electric bill offset for Zhongshan Ruike New Energy Co Ltd RK-105.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 58 | 6.09 kW | 450 sq ft | $1,524 | $2,577 |
| 8 kW Class | 77 | 8.09 kW | 597 sq ft | $2,025 | $3,424 |
| 10 kW Class | 96 | 10.08 kW | 744 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Zhongshan Ruike New Energy Co Ltd Series?
Sibling wattage bins and frame colors grouped with Zhongshan Ruike New Energy Co Ltd RK-105 under Zhongshan Ruike New Energy Co Ltd to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Zhongshan Ruike New Energy Co Ltd RK-100 | 100.0 W | 93.0 W | 118.2 V | 88.2 V | 13.89% |
| Zhongshan Ruike New Energy Co Ltd RK-105 | 105.0 W | 97.7 W | 120.1 V | 90.6 V | 14.58% |
| Zhongshan Ruike New Energy Co Ltd RK-110 | 110.0 W | 102.4 W | 121.6 V | 93.1 V | 15.28% |
How Many Zhongshan Ruike New Energy Co Ltd RK-105 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Zhongshan Ruike New Energy Co Ltd RK-105 (beta_Voc -0.326%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 137.72 V | 4 panels | 550.9 V | 7 panels |
| -10 C (14 F) | 133.8 V | 4 panels | 535.2 V | 7 panels |
| 0 C (32 F) | 129.89 V | 4 panels | 519.6 V | 7 panels |
| 25 C (77 F STC) | 120.1 V | 4 panels | 480.4 V | 8 panels |
Which Cross-Brand Solar Modules Compare Closest to Zhongshan Ruike New Energy Co Ltd RK-105?
Closest cross-brand CEC competitors to Zhongshan Ruike New Energy Co Ltd RK-105 matched near 105.0 W STC and 120.1 V Voc, led by Advanced Solar Power (Hangzhou) ASP-S1-80.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Advanced Solar Power (Hangzhou) ASP-S1-80 Advanced Solar Power (Hangzhou) |
80.0 W | -25.0 W | 118.9 V | 11.11% | 94.0% |
| Applied Materials 1/4 Size Tandem Junction Applied Materials |
114.0 W | +9.0 W | 137.6 V | 7.97% | 91.8% |
| Du Pont Apollo DA105-A2 Du Pont Apollo |
105.0 W | Tie (0 W) | 100.0 V | 6.82% | 91.0% |
| Du Pont Apollo DA102-A6 Du Pont Apollo |
102.0 W | -3.0 W | 100.0 V | 6.62% | 94.2% |
What Are the Design Limits and Best-Fit Uses for Zhongshan Ruike New Energy Co Ltd RK-105?
Evaluate Zhongshan Ruike New Energy Co Ltd RK-105 (105.0 W STC, 120.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Zhongshan Ruike New Energy Co Ltd RK-105 reaches 137.72 V per panel—exceeding 4 panels in series voids 600 V inverter warranties.
- Footprint constraint: 77 panels for an 8 kW build require 597 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 77 panels (597 sq ft).
- 2026 tax credit baseline: cash residential installs of Zhongshan Ruike New Energy Co Ltd RK-105 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Zhongshan Ruike New Energy Co Ltd RK-105 8 kW Residential Fit
Needs 77 modules (597 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 4 panels (-10 C) or 4 panels (-20 C), or compare Advanced Solar Power (Hangzhou) ASP-S1-80.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 97.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Zhongshan Ruike New Energy Co Ltd RK-105 by Zhongshan Ruike New Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Zhongshan Ruike New Energy Co Ltd RK-105 panels fit on a 600 V winter solar string?
At -10 C (14 F), Zhongshan Ruike New Energy Co Ltd RK-105 cold Voc rises from 120.1 V to 133.8 V (beta_Voc -0.326%/C), capping a 600 V string at 4 panels (535.2 V).
How much roof area does an 8 kW array of Zhongshan Ruike New Energy Co Ltd RK-105 need?
An 8 kW DC system uses 77 Zhongshan Ruike New Energy Co Ltd RK-105 modules (8,085 W STC / 7,523 W PTC), covering roughly 597 sq ft and saving ~$2,025/yr at 18.54 c/kWh.
How does Zhongshan Ruike New Energy Co Ltd RK-105 compare against Advanced Solar Power (Hangzhou) ASP-S1-80?
Zhongshan Ruike New Energy Co Ltd RK-105 outputs 105.0 W STC (120.1 V Voc, rank #21,543 of 21,677), while Advanced Solar Power (Hangzhou) ASP-S1-80 delivers 80.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)