Manufacturer: Zhongshan Ruike New Energy Co Ltd Registry: CEC Verified Engineering Specification

Zhongshan Ruike New Energy Co Ltd RK-105-2 is a 105.0 W STC (99.1 W PTC) CdTe solar module ranking #21,543 of 21,677 CEC listings (below all-CEC median; higher than 0.6% of peers). It delivers 14.58% efficiency, 59.1 V Voc at 25 C, and 65.64 V cold Voc at -10 C (9 panels max per 600 V string).

STC Wattage
105.0 W
PTC Wattage
99.1 W
Voc @ 25C
59.1 V
Efficiency
14.58%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Zhongshan Ruike New Energy Co Ltd RK-105-2 Compare Against Peer CEC Listings?

Solar engineering breakdown for Zhongshan Ruike New Energy Co Ltd RK-105-2: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 131 CdTe listings from Zhongshan Ruike New Energy Co Ltd and peers, Zhongshan Ruike New Energy Co Ltd RK-105-2 stands 340.0 W below the 445.0 W CdTe median and strong 94.4% PTC-to-STC heat retention (#2,840 of 21,677). Sizing 6 kW (58 panels) to 10 kW (96 panels) yields $1,524-$2,523/yr in baseline US bill offset. Higher 59.1 V open-circuit voltage caps 600 V residential strings at 9 panels at 14 F (-10 C).

Where Does Zhongshan Ruike New Energy Co Ltd RK-105-2 Fall Across Listed CEC Models?

Distribution marker showing Zhongshan Ruike New Energy Co Ltd RK-105-2 (105.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Zhongshan Ruike New Energy Co Ltd RK-105-2 (105.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCZhongshan Ruike Ne: 105.0 W

What Dataset Percentiles Define Zhongshan Ruike New Energy Co Ltd RK-105-2?

Dataset percentiles tracking Zhongshan Ruike New Energy Co Ltd RK-105-2 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Zhongshan Ruike New Energy Co Ltd RK-105-2 Engineering BenchmarksPercentile comparison of Zhongshan Ruike New Energy Co Ltd RK-105-2 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage105.0 WPTC/STC Retention94.4%Module Efficiency14.58%

What Do the Dataset Ranks Show for Zhongshan Ruike New Energy Co Ltd RK-105-2?

Benchmark highlights for Zhongshan Ruike New Energy Co Ltd RK-105-2 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #21,543 / 21,677

105.0 W STC · Higher Than 0.6%

105.0 W STC (-280.0 W vs all-CEC median) vs 445.0 W CdTe median.

Eff #20,303

14.58% Aperture Efficiency

Power density 145.8 W/m2 (5.33 percentage points below 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).

NEC 690.7 Limit

9 Panels Max @ -10 C (600 V)

Cold Voc reaches 65.64 V at -10 C (590.8 V string) and 67.5 V at -20 C (8 max).

8 kW Reference Array

77 Panels = 8,085 W STC

Occupies 55.4 m2 (597 sq ft) producing 7,631 W PTC; NEC 690.8 OCPD floor is 4.06 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 59.1 * (1 + (-0.316/100) * (-10 - 25)) = 65.64 V | OCPD = 1.56 * 2.6 = 4.06 A

Inputs from CEC Modules.csv for Zhongshan Ruike New Energy Co Ltd RK-105-2: Voc=59.1 V, beta_Voc=-0.316%/C, Isc=2.6 A, STC=105.0 W, Area=0.72 m2.

Result: 9 panels max on 600 V (590.8 V); 77 panels for 8 kW (597 sq ft).

What Are the Published CEC Specifications for Zhongshan Ruike New Energy Co Ltd RK-105-2?

Official CEC datasheet figures for Zhongshan Ruike New Energy Co Ltd RK-105-2 (CdTe) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Zhongshan Ruike New Energy Co Ltd RK-105-2.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 105.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 99.1 W (94.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 59.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 2.6 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 45.8 V / 2.4 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.316 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.58% (0.72 m2) Array roof footprint density
Cell Count & Technology 73 cells (CdTe) Monofacial backsheet

How Many Zhongshan Ruike New Energy Co Ltd RK-105-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Zhongshan Ruike New Energy Co Ltd RK-105-2 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 58 6.09 kW 450 sq ft $1,524 $2,577
8 kW Class 77 8.09 kW 597 sq ft $2,025 $3,424
10 kW Class 96 10.08 kW 744 sq ft $2,523 $4,266

How Many Zhongshan Ruike New Energy Co Ltd RK-105-2 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Zhongshan Ruike New Energy Co Ltd RK-105-2 (65.64 V at 14 F).

Computed from Voc=59.1V and beta_Voc=-0.316%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 67.5 V 8 panels 540.0 V 14 panels
-10 C (14 F) 65.64 V 9 panels 590.8 V 15 panels
0 C (32 F) 63.77 V 9 panels 573.9 V 15 panels
25 C (77 F STC) 59.1 V 10 panels 591.0 V 16 panels

Which Cross-Brand Solar Modules Compare Closest to Zhongshan Ruike New Energy Co Ltd RK-105-2?

Competing CEC solar panels closest to Zhongshan Ruike New Energy Co Ltd RK-105-2 in nameplate wattage and Voc, starting with First Solar Inc FS-3100-Plus.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
First Solar Inc FS-3100-Plus
First Solar Inc
100.0 W -5.0 W 58.8 V 13.89% 94.8%
First Solar Inc FS-392-Plus
First Solar Inc
92.5 W -12.5 W 57.7 V 12.85% 94.7%
First Solar Inc FS-385
First Solar Inc
85.0 W -20.0 W 61.0 V 11.81% 95.1%
Centrosolar America VS-140C1
Centrosolar America
140.0 W +35.0 W 60.6 V 12.89% 92.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Zhongshan Ruike New Energy Co Ltd RK-105-2?

Evaluate Zhongshan Ruike New Energy Co Ltd RK-105-2 (105.0 W STC, 59.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Zhongshan Ruike New Energy Co Ltd RK-105-2 reaches 67.5 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 77 panels for an 8 kW build require 597 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 77 panels (597 sq ft).
  • 2026 tax credit baseline: cash residential installs of Zhongshan Ruike New Energy Co Ltd RK-105-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Zhongshan Ruike New Energy Co Ltd RK-105-2 8 kW Residential Fit

Needs 77 modules (597 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 9 panels (-10 C) or 8 panels (-20 C), or compare First Solar Inc FS-3100-Plus.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 99.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Zhongshan Ruike New Energy Co Ltd RK-105-2 by Zhongshan Ruike New Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Zhongshan Ruike New Energy Co Ltd RK-105-2?

Multiplying Zhongshan Ruike New Energy Co Ltd RK-105-2's 2.6 A short-circuit current by 1.56 equals 4.06 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Zhongshan Ruike New Energy Co Ltd RK-105-2 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 65.64 V cold Voc at 14 F and handles 2.6 A Isc; string inverters cap Zhongshan Ruike New Energy Co Ltd RK-105-2 at 9 panels on 600 V.

Is Zhongshan Ruike New Energy Co Ltd RK-105-2 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Zhongshan Ruike New Energy Co Ltd RK-105-2 rely on utility bill offset (~$2,025/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.