Zhongshan Ruike New Energy Co Ltd RK-105-2 is a 105.0 W STC (99.1 W PTC) CdTe solar module ranking #21,543 of 21,677 CEC listings (below all-CEC median; higher than 0.6% of peers). It delivers 14.58% efficiency, 59.1 V Voc at 25 C, and 65.64 V cold Voc at -10 C (9 panels max per 600 V string).
- STC Wattage
- 105.0 W
- PTC Wattage
- 99.1 W
- Voc @ 25C
- 59.1 V
- Efficiency
- 14.58%
How Does Zhongshan Ruike New Energy Co Ltd RK-105-2 Compare Against Peer CEC Listings?
Solar engineering breakdown for Zhongshan Ruike New Energy Co Ltd RK-105-2: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 131 CdTe listings from Zhongshan Ruike New Energy Co Ltd and peers, Zhongshan Ruike New Energy Co Ltd RK-105-2 stands 340.0 W below the 445.0 W CdTe median and strong 94.4% PTC-to-STC heat retention (#2,840 of 21,677). Sizing 6 kW (58 panels) to 10 kW (96 panels) yields $1,524-$2,523/yr in baseline US bill offset. Higher 59.1 V open-circuit voltage caps 600 V residential strings at 9 panels at 14 F (-10 C).
Where Does Zhongshan Ruike New Energy Co Ltd RK-105-2 Fall Across Listed CEC Models?
Distribution marker showing Zhongshan Ruike New Energy Co Ltd RK-105-2 (105.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Zhongshan Ruike New Energy Co Ltd RK-105-2?
Dataset percentiles tracking Zhongshan Ruike New Energy Co Ltd RK-105-2 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Zhongshan Ruike New Energy Co Ltd RK-105-2?
Benchmark highlights for Zhongshan Ruike New Energy Co Ltd RK-105-2 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
105.0 W STC · Higher Than 0.6%
105.0 W STC (-280.0 W vs all-CEC median) vs 445.0 W CdTe median.
14.58% Aperture Efficiency
Power density 145.8 W/m2 (5.33 percentage points below 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).
9 Panels Max @ -10 C (600 V)
Cold Voc reaches 65.64 V at -10 C (590.8 V string) and 67.5 V at -20 C (8 max).
77 Panels = 8,085 W STC
Occupies 55.4 m2 (597 sq ft) producing 7,631 W PTC; NEC 690.8 OCPD floor is 4.06 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 59.1 * (1 + (-0.316/100) * (-10 - 25)) = 65.64 V | OCPD = 1.56 * 2.6 = 4.06 A
Inputs from CEC Modules.csv for Zhongshan Ruike New Energy Co Ltd RK-105-2: Voc=59.1 V, beta_Voc=-0.316%/C, Isc=2.6 A, STC=105.0 W, Area=0.72 m2.
Result: 9 panels max on 600 V (590.8 V); 77 panels for 8 kW (597 sq ft).
What Are the Published CEC Specifications for Zhongshan Ruike New Energy Co Ltd RK-105-2?
Official CEC datasheet figures for Zhongshan Ruike New Energy Co Ltd RK-105-2 (CdTe) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 105.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 99.1 W (94.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 59.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.6 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 45.8 V / 2.4 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.316 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 14.58% (0.72 m2) | Array roof footprint density |
| Cell Count & Technology | 73 cells (CdTe) | Monofacial backsheet |
How Many Zhongshan Ruike New Energy Co Ltd RK-105-2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Zhongshan Ruike New Energy Co Ltd RK-105-2 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 58 | 6.09 kW | 450 sq ft | $1,524 | $2,577 |
| 8 kW Class | 77 | 8.09 kW | 597 sq ft | $2,025 | $3,424 |
| 10 kW Class | 96 | 10.08 kW | 744 sq ft | $2,523 | $4,266 |
How Many Zhongshan Ruike New Energy Co Ltd RK-105-2 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Zhongshan Ruike New Energy Co Ltd RK-105-2 (65.64 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 67.5 V | 8 panels | 540.0 V | 14 panels |
| -10 C (14 F) | 65.64 V | 9 panels | 590.8 V | 15 panels |
| 0 C (32 F) | 63.77 V | 9 panels | 573.9 V | 15 panels |
| 25 C (77 F STC) | 59.1 V | 10 panels | 591.0 V | 16 panels |
Which Cross-Brand Solar Modules Compare Closest to Zhongshan Ruike New Energy Co Ltd RK-105-2?
Competing CEC solar panels closest to Zhongshan Ruike New Energy Co Ltd RK-105-2 in nameplate wattage and Voc, starting with First Solar Inc FS-3100-Plus.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| First Solar Inc FS-3100-Plus First Solar Inc |
100.0 W | -5.0 W | 58.8 V | 13.89% | 94.8% |
| First Solar Inc FS-392-Plus First Solar Inc |
92.5 W | -12.5 W | 57.7 V | 12.85% | 94.7% |
| First Solar Inc FS-385 First Solar Inc |
85.0 W | -20.0 W | 61.0 V | 11.81% | 95.1% |
| Centrosolar America VS-140C1 Centrosolar America |
140.0 W | +35.0 W | 60.6 V | 12.89% | 92.7% |
What Are the Design Limits and Best-Fit Uses for Zhongshan Ruike New Energy Co Ltd RK-105-2?
Evaluate Zhongshan Ruike New Energy Co Ltd RK-105-2 (105.0 W STC, 59.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Zhongshan Ruike New Energy Co Ltd RK-105-2 reaches 67.5 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
- Footprint constraint: 77 panels for an 8 kW build require 597 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 77 panels (597 sq ft).
- 2026 tax credit baseline: cash residential installs of Zhongshan Ruike New Energy Co Ltd RK-105-2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Zhongshan Ruike New Energy Co Ltd RK-105-2 8 kW Residential Fit
Needs 77 modules (597 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 9 panels (-10 C) or 8 panels (-20 C), or compare First Solar Inc FS-3100-Plus.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 99.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Zhongshan Ruike New Energy Co Ltd RK-105-2 by Zhongshan Ruike New Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Zhongshan Ruike New Energy Co Ltd RK-105-2?
Multiplying Zhongshan Ruike New Energy Co Ltd RK-105-2's 2.6 A short-circuit current by 1.56 equals 4.06 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Zhongshan Ruike New Energy Co Ltd RK-105-2 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 65.64 V cold Voc at 14 F and handles 2.6 A Isc; string inverters cap Zhongshan Ruike New Energy Co Ltd RK-105-2 at 9 panels on 600 V.
Is Zhongshan Ruike New Energy Co Ltd RK-105-2 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Zhongshan Ruike New Energy Co Ltd RK-105-2 rely on utility bill offset (~$2,025/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)