Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-3100-Plus is a 100.0 W STC (94.8 W PTC) Thin Film solar module ranking #21,563 of 21,677 CEC listings (below all-CEC median; higher than 0.5% of peers). It delivers 13.89% efficiency, 58.8 V Voc at 25 C, and 63.94 V cold Voc at -10 C (9 panels max per 600 V string).

STC Wattage
100.0 W
PTC Wattage
94.8 W
Voc @ 25C
58.8 V
Efficiency
13.89%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-3100-Plus Compare Against Peer CEC Listings?

How First Solar Inc First Solar Inc FS-3100-Plus handles rooftop heat (94.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, First Solar Inc FS-3100-Plus exhibits 2.33 A short-circuit current, requiring a 3.63 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #21,563 of 21,677 (17.5 W below the 117.5 W Thin Film median), this compact residential or specialty off-grid module covers 57.6 m2 for an 8 kW system (100 panels for 10 kW). Higher 58.8 V open-circuit voltage caps 600 V residential strings at 9 panels at 14 F (-10 C).

Where Does First Solar Inc FS-3100-Plus Fall Across Listed CEC Models?

Where First Solar Inc FS-3100-Plus (100.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-3100-Plus (100.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 100.0 W

What Dataset Percentiles Define First Solar Inc FS-3100-Plus?

Percentile placement of First Solar Inc FS-3100-Plus across power density (138.9 W/m2), thermal retention, and nameplate STC wattage.

First Solar Inc FS-3100-Plus Engineering BenchmarksPercentile comparison of First Solar Inc FS-3100-Plus wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage100.0 WPTC/STC Retention94.8%Module Efficiency13.89%

What Do the Dataset Ranks Show for First Solar Inc FS-3100-Plus?

Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-3100-Plus specifications. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Rank #21,563 / 21,677

100.0 W STC · Higher Than 0.5%

100.0 W STC (-285.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #20,983

13.89% Aperture Efficiency

Power density 138.9 W/m2 (6.02 percentage points below 19.91% CEC median). PTC/STC ratio: 94.8% (rank #1,790).

NEC 690.7 Limit

9 Panels Max @ -10 C (600 V)

Cold Voc reaches 63.94 V at -10 C (575.5 V string) and 65.42 V at -20 C (9 max).

8 kW Reference Array

80 Panels = 8,000 W STC

Occupies 57.6 m2 (620 sq ft) producing 7,584 W PTC; NEC 690.8 OCPD floor is 3.63 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 58.8 * (1 + (-0.25/100) * (-10 - 25)) = 63.94 V | OCPD = 1.56 * 2.33 = 3.63 A

Inputs from CEC Modules.csv for First Solar Inc FS-3100-Plus: Voc=58.8 V, beta_Voc=-0.25%/C, Isc=2.33 A, STC=100.0 W, Area=0.72 m2.

Result: 9 panels max on 600 V (575.5 V); 80 panels for 8 kW (620 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-3100-Plus?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-3100-Plus.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-3100-Plus.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 100.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 94.8 W (94.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 58.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 2.33 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 46.8 V / 2.14 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.25 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 13.89% (0.72 m2) Array roof footprint density
Cell Count & Technology 146 cells (Thin Film) Monofacial backsheet

How Many First Solar Inc FS-3100-Plus Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-3100-Plus (100.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 60 6.0 kW 465 sq ft $1,502 $2,539
8 kW Class 80 8.0 kW 620 sq ft $2,002 $3,386
10 kW Class 100 10.0 kW 775 sq ft $2,503 $4,232

How Many First Solar Inc FS-3100-Plus Modules Fit in a Cold-Weather String?

Maximum series module counts for First Solar Inc FS-3100-Plus from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=58.8V and beta_Voc=-0.25%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 65.42 V 9 panels 588.8 V 15 panels
-10 C (14 F) 63.94 V 9 panels 575.5 V 15 panels
0 C (32 F) 62.47 V 9 panels 562.2 V 16 panels
25 C (77 F STC) 58.8 V 10 panels 588.0 V 17 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-3100-Plus?

Alternative CEC solar modules from competing brands near First Solar Inc FS-3100-Plus (100.0 W), including Zhongshan Ruike New Energy Co Ltd RK-105-2.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Zhongshan Ruike New Energy Co Ltd RK-105-2
Zhongshan Ruike New Energy Co Ltd
105.0 W +5.0 W 59.1 V 14.58% 94.4%
Zhongshan Ruike New Energy Co Ltd RK-75-2
Zhongshan Ruike New Energy Co Ltd
75.0 W -25.0 W 58.5 V 10.42% 93.9%
Centrosolar America VS-140C1
Centrosolar America
140.0 W +40.0 W 60.6 V 12.89% 92.7%
Miasole FLEX-03 120N
Miasole
115.1 W +15.1 W 37.8 V 12.82% 90.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-3100-Plus?

Evaluate First Solar Inc FS-3100-Plus (100.0 W STC, 58.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-3100-Plus reaches 65.42 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 80 panels for an 8 kW build require 620 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 80 panels (620 sq ft).
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-3100-Plus carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-3100-Plus 8 kW Residential Fit

Needs 80 modules (620 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare Zhongshan Ruike New Energy Co Ltd RK-105-2.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 94.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-3100-Plus by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

Why is First Solar Inc FS-3100-Plus PTC wattage (94.8 W) lower than STC (100.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 94.8 W PTC (94.8% retention) across First Solar Inc FS-3100-Plus's 0.72 m2 aperture.

Who should skip First Solar Inc FS-3100-Plus on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 80 First Solar Inc FS-3100-Plus panels (620 sq ft) leave unusable roof gaps vs. Zhongshan Ruike New Energy Co Ltd RK-105-2.

What is the 1,000 V commercial string limit for First Solar Inc FS-3100-Plus?

On 1,000 V commercial inverters at -10 C (63.94 V cold Voc), First Solar Inc FS-3100-Plus fits up to 15 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-3100-Plus.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.