Skip to main content
WireAndSun
Calculators
CEC PV Module

Miasole FLEX-03 120N — CEC Solar Module Specifications

Manufacturer: Miasole Registry: CEC Verified Engineering Specification

Miasole FLEX-03 120N is a 115.1 W STC (104.6 W PTC) CIGS solar module ranking #21,510 of 21,677 CEC listings (below all-CEC median; higher than 0.8% of peers). It delivers 12.82% efficiency, 37.8 V Voc at 25 C, and 40.99 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
115.1 W
PTC Wattage
104.6 W
Voc @ 25C
37.8 V
Efficiency
12.82%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Miasole FLEX-03 120N Compare Against Peer CEC Listings?

Engineering position of Miasole FLEX-03 120N (115.1 W STC) vs. Anhui Rinengzhongtian Semiconductor Development QJM165-72 across 8 CEC CIGS solar modules.

Built with 56 CIGS cells, Miasole FLEX-03 120N pairs typical 90.9% PTC-to-STC thermal output (104.6 W real-world rating) with 37.8 V nominal Voc. An 8 kW residential build (8,057 W DC, 7,322 W PTC) saves ~$2,017/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Anhui Rinengzhongtian Semiconductor Development QJM165-72 offers a 165.0 W alternative.

Where Does Miasole FLEX-03 120N Fall Across Listed CEC Models?

Plots Miasole FLEX-03 120N at 115.1 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Miasole FLEX-03 120N (115.1 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCMiasole FLEX-03 12: 115.1 W

What Dataset Percentiles Define Miasole FLEX-03 120N?

Benchmarks Miasole FLEX-03 120N on STC wattage, thermal PTC/STC retention, and 12.82 aperture conversion efficiency against CEC peers.

Miasole FLEX-03 120N Engineering BenchmarksPercentile comparison of Miasole FLEX-03 120N wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage115.1 WPTC/STC Retention90.9%Module Efficiency12.82%

What Do the Dataset Ranks Show for Miasole FLEX-03 120N?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Miasole FLEX-03 120N by Miasole.

Rank #21,510 / 21,677

115.1 W STC · Higher Than 0.8%

115.1 W STC (-269.9 W vs all-CEC median) vs 300.0 W CIGS median.

Eff #21,469

12.82% Aperture Efficiency

Power density 128.2 W/m2 (7.09 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.99 V at -10 C (573.9 V string) and 41.9 V at -20 C (14 max).

8 kW Reference Array

70 Panels = 8,057 W STC

Occupies 62.9 m2 (677 sq ft) producing 7,322 W PTC; NEC 690.8 OCPD floor is 7.14 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.8 * (1 + (-0.241/100) * (-10 - 25)) = 40.99 V | OCPD = 1.56 * 4.58 = 7.14 A

Inputs from CEC Modules.csv for Miasole FLEX-03 120N: Voc=37.8 V, beta_Voc=-0.241%/C, Isc=4.58 A, STC=115.1 W, Area=0.898 m2.

Result: 14 panels max on 600 V (573.9 V); 70 panels for 8 kW (677 sq ft).

What Are the Published CEC Specifications for Miasole FLEX-03 120N?

Laboratory test ratings recorded for Miasole FLEX-03 120N (CIGS) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Miasole FLEX-03 120N.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 115.1 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 104.6 W (90.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 4.58 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.3 V / 3.97 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.241 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 12.82% (0.898 m2) Array roof footprint density
Cell Count & Technology 56 cells (CIGS) Monofacial backsheet

How Many Miasole FLEX-03 120N Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (677 sq ft at 8 kW), and estimated Year-1 electric bill offset for Miasole FLEX-03 120N.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 53 6.1 kW 512 sq ft $1,527 $2,582
8 kW Class 70 8.06 kW 677 sq ft $2,017 $3,411
10 kW Class 87 10.01 kW 841 sq ft $2,505 $4,236

How Many Miasole FLEX-03 120N Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Miasole FLEX-03 120N (beta_Voc -0.241%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.8V and beta_Voc=-0.241%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.9 V 14 panels 586.6 V 23 panels
-10 C (14 F) 40.99 V 14 panels 573.9 V 24 panels
0 C (32 F) 40.08 V 14 panels 561.1 V 24 panels
25 C (77 F STC) 37.8 V 15 panels 567.0 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Miasole FLEX-03 120N?

Closest cross-brand CEC competitors to Miasole FLEX-03 120N matched near 115.1 W STC and 37.8 V Voc, led by Anhui Rinengzhongtian Semiconductor Development QJM165-72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Anhui Rinengzhongtian Semiconductor Development QJM165-72
Anhui Rinengzhongtian Semiconductor Development
165.0 W +49.9 W 42.5 V 12.92% 88.5%
Gintung Energy ASEC-120G6M
Gintung Energy
120.0 W +4.9 W 21.6 V 12.21% 89.1%
Mitsubishi Electric PV-EE120MF5F
Mitsubishi Electric
120.0 W +4.9 W 21.6 V 11.91% 90.6%
United Renewable Energy Co Ltd D6P120A1F
United Renewable Energy Co Ltd
120.0 W +4.9 W 21.6 V 12.21% 89.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Miasole FLEX-03 120N?

Evaluate Miasole FLEX-03 120N (115.1 W STC, 37.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Miasole FLEX-03 120N reaches 41.9 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 70 panels for an 8 kW build require 677 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 70 panels (677 sq ft).
  • 2026 tax credit baseline: cash residential installs of Miasole FLEX-03 120N carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Miasole FLEX-03 120N 8 kW Residential Fit

Needs 70 modules (677 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJM165-72.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 104.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Miasole FLEX-03 120N by Miasole grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Miasole FLEX-03 120N?

Multiplying Miasole FLEX-03 120N's 4.58 A short-circuit current by 1.56 equals 7.14 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Miasole FLEX-03 120N pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.99 V cold Voc at 14 F and handles 4.58 A Isc; string inverters cap Miasole FLEX-03 120N at 14 panels on 600 V.

Is Miasole FLEX-03 120N eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Miasole FLEX-03 120N rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.