First Solar Inc FS-385 is a 85.0 W STC (80.8 W PTC) Thin Film solar module ranking #21,602 of 21,677 CEC listings (below all-CEC median; higher than 0.3% of peers). It delivers 11.81% efficiency, 61.0 V Voc at 25 C, and 64.65 V cold Voc at -10 C (9 panels max per 600 V string).
- STC Wattage
- 85.0 W
- PTC Wattage
- 80.8 W
- Voc @ 25C
- 61.0 V
- Efficiency
- 11.81%
How Does First Solar Inc FS-385 Compare Against Peer CEC Listings?
Engineering position of First Solar Inc FS-385 (85.0 W STC) vs. Zhongshan Ruike New Energy Co Ltd RK-75-2 across 106 CEC Thin Film solar modules.
Ranking #21,602 across 21,677 CEC solar panels (below all-CEC median; higher than 0.3% of peers), First Solar Inc FS-385 operates as a compact residential or specialty off-grid module sitting 32.5 W below the 117.5 W Thin Film median. Higher 61.0 V open-circuit voltage caps 600 V residential strings at 9 panels at 14 F (-10 C). With strong 95.1% PTC-to-STC heat retention (#713 of 21,677), 95 panels occupy 736 sq ft and offset roughly $2,020/yr at average US rates (or $3,415/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does First Solar Inc FS-385 Fall Across Listed CEC Models?
Plots First Solar Inc FS-385 at 85.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define First Solar Inc FS-385?
Benchmarks First Solar Inc FS-385 on STC wattage, thermal PTC/STC retention, and 11.81 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for First Solar Inc FS-385?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for First Solar Inc FS-385 by First Solar Inc.
85.0 W STC · Higher Than 0.3%
85.0 W STC (-300.0 W vs all-CEC median) vs 117.5 W Thin Film median.
11.81% Aperture Efficiency
Power density 118.1 W/m2 (8.10 percentage points below 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).
9 Panels Max @ -10 C (600 V)
Cold Voc reaches 64.65 V at -10 C (581.9 V string) and 65.69 V at -20 C (9 max).
95 Panels = 8,075 W STC
Occupies 68.4 m2 (736 sq ft) producing 7,676 W PTC; NEC 690.8 OCPD floor is 3.09 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 61.0 * (1 + (-0.171/100) * (-10 - 25)) = 64.65 V | OCPD = 1.56 * 1.98 = 3.09 A
Inputs from CEC Modules.csv for First Solar Inc FS-385: Voc=61.0 V, beta_Voc=-0.171%/C, Isc=1.98 A, STC=85.0 W, Area=0.72 m2.
Result: 9 panels max on 600 V (581.9 V); 95 panels for 8 kW (736 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-385?
Laboratory test ratings recorded for First Solar Inc FS-385 (Thin Film) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 85.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 80.8 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 61.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 1.98 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 48.5 V / 1.76 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.171 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 11.81% (0.72 m2) | Array roof footprint density |
| Cell Count & Technology | 77 cells (Thin Film) | Monofacial backsheet |
How Many First Solar Inc FS-385 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (736 sq ft at 8 kW), and estimated Year-1 electric bill offset for First Solar Inc FS-385.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 71 | 6.04 kW | 550 sq ft | $1,512 | $2,556 |
| 8 kW Class | 95 | 8.07 kW | 736 sq ft | $2,020 | $3,415 |
| 10 kW Class | 118 | 10.03 kW | 915 sq ft | $2,510 | $4,245 |
Which Sibling Wattage & Trim Variants Belong to This First Solar Inc Series?
Sibling wattage bins and frame colors grouped with First Solar Inc FS-385 under First Solar Inc to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| First Solar Inc FS-375 | 75.0 W | 71.2 W | 61.6 V | 49.8 V | 10.42% |
| First Solar Inc FS-377 | 77.0 W | 73.1 W | 61.7 V | 50.4 V | 10.69% |
| First Solar Inc FS-380 | 80.0 W | 76.0 W | 61.7 V | 50.7 V | 11.11% |
| First Solar Inc FS-382 | 82.5 W | 78.4 W | 62.0 V | 51.0 V | 11.46% |
| First Solar Inc FS-385 | 85.0 W | 80.8 W | 61.0 V | 48.5 V | 11.81% |
| First Solar Inc FS-387 | 87.5 W | 83.4 W | 61.0 V | 49.2 V | 12.15% |
| First Solar Inc FS-390 | 90.0 W | 85.8 W | 61.0 V | 49.2 V | 12.5% |
| First Solar Inc FS-392 | 92.5 W | 88.5 W | 61.0 V | 49.5 V | 12.85% |
| First Solar Inc FS-395 | 95.0 W | 90.9 W | 60.5 V | 47.5 V | 13.19% |
How Many First Solar Inc FS-385 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for First Solar Inc FS-385 (beta_Voc -0.171%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 65.69 V | 9 panels | 591.2 V | 15 panels |
| -10 C (14 F) | 64.65 V | 9 panels | 581.9 V | 15 panels |
| 0 C (32 F) | 63.61 V | 9 panels | 572.5 V | 15 panels |
| 25 C (77 F STC) | 61.0 V | 9 panels | 549.0 V | 16 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-385?
Closest cross-brand CEC competitors to First Solar Inc FS-385 matched near 85.0 W STC and 61.0 V Voc, led by Zhongshan Ruike New Energy Co Ltd RK-75-2.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Zhongshan Ruike New Energy Co Ltd RK-75-2 Zhongshan Ruike New Energy Co Ltd |
75.0 W | -10.0 W | 58.5 V | 10.42% | 93.9% |
| Centrosolar America VS-140C1 Centrosolar America |
140.0 W | +55.0 W | 60.6 V | 12.89% | 92.7% |
| Miasole FLEX-03 120N Miasole |
115.1 W | +30.1 W | 37.8 V | 12.82% | 90.9% |
| Centrosolar America VS-140C2 Centrosolar America |
140.0 W | +55.0 W | 79.95 V | 12.89% | 92.9% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-385?
Evaluate First Solar Inc FS-385 (85.0 W STC, 61.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-385 reaches 65.69 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 95 panels for an 8 kW build require 736 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 95 panels (736 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-385 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-385 8 kW Residential Fit
Needs 95 modules (736 sq ft) with a 15 A string OCPD, offsetting ~$2,020/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare Zhongshan Ruike New Energy Co Ltd RK-75-2.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 80.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-385 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
How many First Solar Inc FS-385 panels fit on a 600 V winter solar string?
At -10 C (14 F), First Solar Inc FS-385 cold Voc rises from 61.0 V to 64.65 V (beta_Voc -0.171%/C), capping a 600 V string at 9 panels (581.9 V).
How much roof area does an 8 kW array of First Solar Inc FS-385 need?
An 8 kW DC system uses 95 First Solar Inc FS-385 modules (8,075 W STC / 7,676 W PTC), covering roughly 736 sq ft and saving ~$2,020/yr at 18.54 c/kWh.
How does First Solar Inc FS-385 compare against Zhongshan Ruike New Energy Co Ltd RK-75-2?
First Solar Inc FS-385 outputs 85.0 W STC (61.0 V Voc, rank #21,602 of 21,677), while Zhongshan Ruike New Energy Co Ltd RK-75-2 delivers 75.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)