Skip to main content
WireAndSun
Calculators
CEC PV Module

First Solar Inc FS-385 — CEC Solar Module Specifications

Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-385 is a 85.0 W STC (80.8 W PTC) Thin Film solar module ranking #21,602 of 21,677 CEC listings (below all-CEC median; higher than 0.3% of peers). It delivers 11.81% efficiency, 61.0 V Voc at 25 C, and 64.65 V cold Voc at -10 C (9 panels max per 600 V string).

STC Wattage
85.0 W
PTC Wattage
80.8 W
Voc @ 25C
61.0 V
Efficiency
11.81%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-385 Compare Against Peer CEC Listings?

Engineering position of First Solar Inc FS-385 (85.0 W STC) vs. Zhongshan Ruike New Energy Co Ltd RK-75-2 across 106 CEC Thin Film solar modules.

Ranking #21,602 across 21,677 CEC solar panels (below all-CEC median; higher than 0.3% of peers), First Solar Inc FS-385 operates as a compact residential or specialty off-grid module sitting 32.5 W below the 117.5 W Thin Film median. Higher 61.0 V open-circuit voltage caps 600 V residential strings at 9 panels at 14 F (-10 C). With strong 95.1% PTC-to-STC heat retention (#713 of 21,677), 95 panels occupy 736 sq ft and offset roughly $2,020/yr at average US rates (or $3,415/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does First Solar Inc FS-385 Fall Across Listed CEC Models?

Plots First Solar Inc FS-385 at 85.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-385 (85.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 85.0 W

What Dataset Percentiles Define First Solar Inc FS-385?

Benchmarks First Solar Inc FS-385 on STC wattage, thermal PTC/STC retention, and 11.81 aperture conversion efficiency against CEC peers.

First Solar Inc FS-385 Engineering BenchmarksPercentile comparison of First Solar Inc FS-385 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage85.0 WPTC/STC Retention95.1%Module Efficiency11.81%

What Do the Dataset Ranks Show for First Solar Inc FS-385?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for First Solar Inc FS-385 by First Solar Inc.

Rank #21,602 / 21,677

85.0 W STC · Higher Than 0.3%

85.0 W STC (-300.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,584

11.81% Aperture Efficiency

Power density 118.1 W/m2 (8.10 percentage points below 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).

NEC 690.7 Limit

9 Panels Max @ -10 C (600 V)

Cold Voc reaches 64.65 V at -10 C (581.9 V string) and 65.69 V at -20 C (9 max).

8 kW Reference Array

95 Panels = 8,075 W STC

Occupies 68.4 m2 (736 sq ft) producing 7,676 W PTC; NEC 690.8 OCPD floor is 3.09 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 61.0 * (1 + (-0.171/100) * (-10 - 25)) = 64.65 V | OCPD = 1.56 * 1.98 = 3.09 A

Inputs from CEC Modules.csv for First Solar Inc FS-385: Voc=61.0 V, beta_Voc=-0.171%/C, Isc=1.98 A, STC=85.0 W, Area=0.72 m2.

Result: 9 panels max on 600 V (581.9 V); 95 panels for 8 kW (736 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-385?

Laboratory test ratings recorded for First Solar Inc FS-385 (Thin Film) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-385.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 85.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 80.8 W (95.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 61.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 1.98 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 48.5 V / 1.76 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.171 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 11.81% (0.72 m2) Array roof footprint density
Cell Count & Technology 77 cells (Thin Film) Monofacial backsheet

How Many First Solar Inc FS-385 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (736 sq ft at 8 kW), and estimated Year-1 electric bill offset for First Solar Inc FS-385.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 71 6.04 kW 550 sq ft $1,512 $2,556
8 kW Class 95 8.07 kW 736 sq ft $2,020 $3,415
10 kW Class 118 10.03 kW 915 sq ft $2,510 $4,245

Which Sibling Wattage & Trim Variants Belong to This First Solar Inc Series?

Sibling wattage bins and frame colors grouped with First Solar Inc FS-385 under First Solar Inc to prevent duplicate spec pages.

Sibling CEC listings grouped into the First Solar Inc FS-385 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
First Solar Inc FS-375 75.0 W 71.2 W 61.6 V 49.8 V 10.42%
First Solar Inc FS-377 77.0 W 73.1 W 61.7 V 50.4 V 10.69%
First Solar Inc FS-380 80.0 W 76.0 W 61.7 V 50.7 V 11.11%
First Solar Inc FS-382 82.5 W 78.4 W 62.0 V 51.0 V 11.46%
First Solar Inc FS-385 85.0 W 80.8 W 61.0 V 48.5 V 11.81%
First Solar Inc FS-387 87.5 W 83.4 W 61.0 V 49.2 V 12.15%
First Solar Inc FS-390 90.0 W 85.8 W 61.0 V 49.2 V 12.5%
First Solar Inc FS-392 92.5 W 88.5 W 61.0 V 49.5 V 12.85%
First Solar Inc FS-395 95.0 W 90.9 W 60.5 V 47.5 V 13.19%

How Many First Solar Inc FS-385 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for First Solar Inc FS-385 (beta_Voc -0.171%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=61.0V and beta_Voc=-0.171%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 65.69 V 9 panels 591.2 V 15 panels
-10 C (14 F) 64.65 V 9 panels 581.9 V 15 panels
0 C (32 F) 63.61 V 9 panels 572.5 V 15 panels
25 C (77 F STC) 61.0 V 9 panels 549.0 V 16 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-385?

Closest cross-brand CEC competitors to First Solar Inc FS-385 matched near 85.0 W STC and 61.0 V Voc, led by Zhongshan Ruike New Energy Co Ltd RK-75-2.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Zhongshan Ruike New Energy Co Ltd RK-75-2
Zhongshan Ruike New Energy Co Ltd
75.0 W -10.0 W 58.5 V 10.42% 93.9%
Centrosolar America VS-140C1
Centrosolar America
140.0 W +55.0 W 60.6 V 12.89% 92.7%
Miasole FLEX-03 120N
Miasole
115.1 W +30.1 W 37.8 V 12.82% 90.9%
Centrosolar America VS-140C2
Centrosolar America
140.0 W +55.0 W 79.95 V 12.89% 92.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-385?

Evaluate First Solar Inc FS-385 (85.0 W STC, 61.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-385 reaches 65.69 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 95 panels for an 8 kW build require 736 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 95 panels (736 sq ft).
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-385 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-385 8 kW Residential Fit

Needs 95 modules (736 sq ft) with a 15 A string OCPD, offsetting ~$2,020/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare Zhongshan Ruike New Energy Co Ltd RK-75-2.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 80.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-385 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

How many First Solar Inc FS-385 panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-385 cold Voc rises from 61.0 V to 64.65 V (beta_Voc -0.171%/C), capping a 600 V string at 9 panels (581.9 V).

How much roof area does an 8 kW array of First Solar Inc FS-385 need?

An 8 kW DC system uses 95 First Solar Inc FS-385 modules (8,075 W STC / 7,676 W PTC), covering roughly 736 sq ft and saving ~$2,020/yr at 18.54 c/kWh.

How does First Solar Inc FS-385 compare against Zhongshan Ruike New Energy Co Ltd RK-75-2?

First Solar Inc FS-385 outputs 85.0 W STC (61.0 V Voc, rank #21,602 of 21,677), while Zhongshan Ruike New Energy Co Ltd RK-75-2 delivers 75.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.