Centrosolar America VS-140C2 is a 140.0 W STC (130.1 W PTC) Thin Film solar module ranking #21,440 of 21,677 CEC listings (below all-CEC median; higher than 1.0% of peers). It delivers 12.89% efficiency, 79.95 V Voc at 25 C, and 88.09 V cold Voc at -10 C (6 panels max per 600 V string).
- STC Wattage
- 140.0 W
- PTC Wattage
- 130.1 W
- Voc @ 25C
- 79.95 V
- Efficiency
- 12.89%
How Does Centrosolar America VS-140C2 Compare Against Peer CEC Listings?
Engineering position of Centrosolar America VS-140C2 (140.0 W STC) vs. First Solar Inc FS-4122-3 across 106 CEC Thin Film solar modules.
Ranking #21,440 across 21,677 CEC solar panels (below all-CEC median; higher than 1.0% of peers), Centrosolar America VS-140C2 operates as a compact residential or specialty off-grid module sitting 22.5 W above the 117.5 W Thin Film median. Higher 79.95 V open-circuit voltage caps 600 V residential strings at 6 panels at 14 F (-10 C). With strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677), 58 panels occupy 678 sq ft and offset roughly $2,032/yr at average US rates (or $3,437/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Centrosolar America VS-140C2 Fall Across Listed CEC Models?
Plots Centrosolar America VS-140C2 at 140.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Centrosolar America VS-140C2?
Benchmarks Centrosolar America VS-140C2 on STC wattage, thermal PTC/STC retention, and 12.89 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Centrosolar America VS-140C2?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Centrosolar America VS-140C2 by Centrosolar America.
140.0 W STC · Higher Than 1.0%
140.0 W STC (-245.0 W vs all-CEC median) vs 117.5 W Thin Film median.
12.89% Aperture Efficiency
Power density 128.9 W/m2 (7.02 percentage points below 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).
6 Panels Max @ -10 C (600 V)
Cold Voc reaches 88.09 V at -10 C (528.5 V string) and 90.42 V at -20 C (6 max).
58 Panels = 8,120 W STC
Occupies 63.0 m2 (678 sq ft) producing 7,546 W PTC; NEC 690.8 OCPD floor is 3.92 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 79.95 * (1 + (-0.291/100) * (-10 - 25)) = 88.09 V | OCPD = 1.56 * 2.51 = 3.92 A
Inputs from CEC Modules.csv for Centrosolar America VS-140C2: Voc=79.95 V, beta_Voc=-0.291%/C, Isc=2.51 A, STC=140.0 W, Area=1.086 m2.
Result: 6 panels max on 600 V (528.5 V); 58 panels for 8 kW (678 sq ft).
What Are the Published CEC Specifications for Centrosolar America VS-140C2?
Laboratory test ratings recorded for Centrosolar America VS-140C2 (Thin Film) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 140.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 130.1 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 79.95 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.51 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 62.78 V / 2.23 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.291 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 12.89% (1.086 m2) | Array roof footprint density |
| Cell Count & Technology | 133 cells (Thin Film) | Monofacial backsheet |
How Many Centrosolar America VS-140C2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (678 sq ft at 8 kW), and estimated Year-1 electric bill offset for Centrosolar America VS-140C2.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 43 | 6.02 kW | 503 sq ft | $1,507 | $2,548 |
| 8 kW Class | 58 | 8.12 kW | 678 sq ft | $2,032 | $3,437 |
| 10 kW Class | 72 | 10.08 kW | 842 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?
Sibling wattage bins and frame colors grouped with Centrosolar America VS-140C2 under Centrosolar America to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Centrosolar America VS-135C2 | 135.0 W | 125.4 W | 79.8 V | 61.64 V | 12.43% |
| Centrosolar America VS-140C2 | 140.0 W | 130.1 W | 79.95 V | 62.78 V | 12.89% |
| Centrosolar America VS-145C2 | 145.0 W | 134.8 W | 80.45 V | 63.87 V | 13.35% |
How Many Centrosolar America VS-140C2 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Centrosolar America VS-140C2 (beta_Voc -0.291%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 90.42 V | 6 panels | 542.5 V | 11 panels |
| -10 C (14 F) | 88.09 V | 6 panels | 528.5 V | 11 panels |
| 0 C (32 F) | 85.77 V | 6 panels | 514.6 V | 11 panels |
| 25 C (77 F STC) | 79.95 V | 7 panels | 559.6 V | 12 panels |
Which Cross-Brand Solar Modules Compare Closest to Centrosolar America VS-140C2?
Closest cross-brand CEC competitors to Centrosolar America VS-140C2 matched near 140.0 W STC and 79.95 V Voc, led by First Solar Inc FS-4122-3.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| First Solar Inc FS-4122-3 First Solar Inc |
122.5 W | -17.5 W | 88.7 V | 17.01% | 93.5% |
| First Solar Inc FS-4122A-3 First Solar Inc |
122.5 W | -17.5 W | 88.7 V | 17.01% | 93.5% |
| Toledo Solar Inc TS1 Toledo Solar Inc |
115.0 W | -25.0 W | 87.1 V | 15.97% | 92.9% |
| First Solar Inc FS-4120-3 First Solar Inc |
120.0 W | -20.0 W | 88.7 V | 16.67% | 93.4% |
What Are the Design Limits and Best-Fit Uses for Centrosolar America VS-140C2?
Evaluate Centrosolar America VS-140C2 (140.0 W STC, 79.95 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America VS-140C2 reaches 90.42 V per panel—exceeding 6 panels in series voids 600 V inverter warranties.
- Footprint constraint: 58 panels for an 8 kW build require 678 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 58 panels (678 sq ft).
- 2026 tax credit baseline: cash residential installs of Centrosolar America VS-140C2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Centrosolar America VS-140C2 8 kW Residential Fit
Needs 58 modules (678 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 6 panels (-10 C) or 6 panels (-20 C), or compare First Solar Inc FS-4122-3.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 130.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Centrosolar America VS-140C2 by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.
How many Centrosolar America VS-140C2 panels fit on a 600 V winter solar string?
At -10 C (14 F), Centrosolar America VS-140C2 cold Voc rises from 79.95 V to 88.09 V (beta_Voc -0.291%/C), capping a 600 V string at 6 panels (528.5 V).
How much roof area does an 8 kW array of Centrosolar America VS-140C2 need?
An 8 kW DC system uses 58 Centrosolar America VS-140C2 modules (8,120 W STC / 7,546 W PTC), covering roughly 678 sq ft and saving ~$2,032/yr at 18.54 c/kWh.
How does Centrosolar America VS-140C2 compare against First Solar Inc FS-4122-3?
Centrosolar America VS-140C2 outputs 140.0 W STC (79.95 V Voc, rank #21,440 of 21,677), while First Solar Inc FS-4122-3 delivers 122.5 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)