First Solar Inc FS-4122A-3 is a 122.5 W STC (114.5 W PTC) Thin Film solar module ranking #21,491 of 21,677 CEC listings (below all-CEC median; higher than 0.9% of peers). It delivers 17.01% efficiency, 88.7 V Voc at 25 C, and 99.85 V cold Voc at -10 C (6 panels max per 600 V string).
- STC Wattage
- 122.5 W
- PTC Wattage
- 114.5 W
- Voc @ 25C
- 88.7 V
- Efficiency
- 17.01%
How Does First Solar Inc FS-4122A-3 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-4122A-3 (Thin Film) residential solar systems.
Homeowners evaluating First Solar Inc FS-4122A-3 need 49 panels for 6 kW or 66 panels (512 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 66 panels (512 sq ft). Under NEC 690.7(A), beta_Voc (-0.359%/C) pushes open-circuit voltage to 99.85 V at 14 F and 103.03 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does First Solar Inc FS-4122A-3 Fall Across Listed CEC Models?
Comparison of First Solar Inc FS-4122A-3 (122.5 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define First Solar Inc FS-4122A-3?
Relative ranking of First Solar Inc FS-4122A-3 across nameplate watts, 93.5% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for First Solar Inc FS-4122A-3?
Summary of First Solar Inc FS-4122A-3 output rank, 8 kW array size (66 panels), efficiency rating, and 600 V string limit.
122.5 W STC · Higher Than 0.9%
122.5 W STC (-262.5 W vs all-CEC median) vs 117.5 W Thin Film median.
17.01% Aperture Efficiency
Power density 170.1 W/m2 (2.90 percentage points below 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).
6 Panels Max @ -10 C (600 V)
Cold Voc reaches 99.85 V at -10 C (599.1 V string) and 103.03 V at -20 C (5 max).
66 Panels = 8,085 W STC
Occupies 47.5 m2 (512 sq ft) producing 7,557 W PTC; NEC 690.8 OCPD floor is 2.89 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 88.7 * (1 + (-0.359/100) * (-10 - 25)) = 99.85 V | OCPD = 1.56 * 1.85 = 2.89 A
Inputs from CEC Modules.csv for First Solar Inc FS-4122A-3: Voc=88.7 V, beta_Voc=-0.359%/C, Isc=1.85 A, STC=122.5 W, Area=0.72 m2.
Result: 6 panels max on 600 V (599.1 V); 66 panels for 8 kW (512 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-4122A-3?
Complete CEC test sheet for First Solar Inc FS-4122A-3 including Isc (1.85 A), Voc (88.7 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 122.5 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 114.5 W (93.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 88.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 1.85 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 71.5 V / 1.71 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.359 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.01% (0.72 m2) | Array roof footprint density |
| Cell Count & Technology | 216 cells (Thin Film) | Monofacial backsheet |
How Many First Solar Inc FS-4122A-3 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-4122A-3.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 49 | 6.0 kW | 380 sq ft | $1,502 | $2,539 |
| 8 kW Class | 66 | 8.09 kW | 512 sq ft | $2,025 | $3,424 |
| 10 kW Class | 82 | 10.04 kW | 636 sq ft | $2,513 | $4,249 |
How Many First Solar Inc FS-4122A-3 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for First Solar Inc FS-4122A-3 (88.7 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 103.03 V | 5 panels | 515.1 V | 9 panels |
| -10 C (14 F) | 99.85 V | 6 panels | 599.1 V | 10 panels |
| 0 C (32 F) | 96.66 V | 6 panels | 580.0 V | 10 panels |
| 25 C (77 F STC) | 88.7 V | 6 panels | 532.2 V | 11 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-4122A-3?
Four comparable CEC modules such as Toledo Solar Inc TS1 (115.0 W) for side-by-side solar quote checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Toledo Solar Inc TS1 Toledo Solar Inc |
115.0 W | -7.5 W | 87.1 V | 15.97% | 92.9% |
| Caterpillar Inc PVT112 Caterpillar Inc |
112.5 W | -10.0 W | 87.7 V | 15.62% | 92.9% |
| Caterpillar Inc PVT112 ARC Caterpillar Inc |
112.5 W | -10.0 W | 87.7 V | 15.62% | 92.9% |
| Applied Materials 1/4 Size Single Junction Version 10 Applied Materials |
116.0 W | -6.5 W | 96.2 V | 8.11% | 93.0% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-4122A-3?
Evaluate First Solar Inc FS-4122A-3 (122.5 W STC, 88.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-4122A-3 reaches 103.03 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
- Footprint constraint: 66 panels for an 8 kW build require 512 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 66 panels (512 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-4122A-3 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-4122A-3 8 kW Residential Fit
Needs 66 modules (512 sq ft) with a 15 A string OCPD, offsetting ~$2,025/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 6 panels (-10 C) or 5 panels (-20 C), or compare Toledo Solar Inc TS1.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 114.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-4122A-3 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
Why is First Solar Inc FS-4122A-3 PTC wattage (114.5 W) lower than STC (122.5 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 114.5 W PTC (93.5% retention) across First Solar Inc FS-4122A-3's 0.72 m2 aperture.
Who should skip First Solar Inc FS-4122A-3 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 66 First Solar Inc FS-4122A-3 panels (512 sq ft) leave unusable roof gaps vs. Toledo Solar Inc TS1.
What is the 1,000 V commercial string limit for First Solar Inc FS-4122A-3?
On 1,000 V commercial inverters at -10 C (99.85 V cold Voc), First Solar Inc FS-4122A-3 fits up to 10 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-4122A-3.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)