Applied Materials 1/4 Size Single Junction Version 10 is a 116.0 W STC (107.9 W PTC) Thin Film solar module ranking #21,509 of 21,677 CEC listings (below all-CEC median; higher than 0.8% of peers). It delivers 8.11% efficiency, 96.2 V Voc at 25 C, and 107.31 V cold Voc at -10 C (5 panels max per 600 V string).
- STC Wattage
- 116.0 W
- PTC Wattage
- 107.9 W
- Voc @ 25C
- 96.2 V
- Efficiency
- 8.11%
How Does Applied Materials 1/4 Size Single Junction Version 10 Compare Against Peer CEC Listings?
Engineering position of Applied Materials 1/4 Size Single Junction Version 10 (116.0 W STC) vs. Du Pont Apollo DA105-A2 across 106 CEC Thin Film solar modules.
Built with 106 Thin Film cells, Applied Materials 1/4 Size Single Junction Version 10 pairs strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677) with 96.2 V nominal Voc. An 8 kW residential build (8,004 W DC, 7,445 W PTC) saves ~$2,002/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Du Pont Apollo DA105-A2 offers a 105.0 W alternative.
Where Does Applied Materials 1/4 Size Single Junction Version 10 Fall Across Listed CEC Models?
Plots Applied Materials 1/4 Size Single Junction Version 10 at 116.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Applied Materials 1/4 Size Single Junction Version 10?
Benchmarks Applied Materials 1/4 Size Single Junction Version 10 on STC wattage, thermal PTC/STC retention, and 8.11 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Applied Materials 1/4 Size Single Junction Version 10?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Applied Materials 1/4 Size Single Junction Version 10 by Applied Materials.
116.0 W STC · Higher Than 0.8%
116.0 W STC (-269.0 W vs all-CEC median) vs 117.5 W Thin Film median.
8.11% Aperture Efficiency
Power density 81.1 W/m2 (11.80 percentage points below 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).
5 Panels Max @ -10 C (600 V)
Cold Voc reaches 107.31 V at -10 C (536.5 V string) and 110.49 V at -20 C (5 max).
69 Panels = 8,004 W STC
Occupies 98.7 m2 (1,062 sq ft) producing 7,445 W PTC; NEC 690.8 OCPD floor is 2.65 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 96.2 * (1 + (-0.33/100) * (-10 - 25)) = 107.31 V | OCPD = 1.56 * 1.7 = 2.65 A
Inputs from CEC Modules.csv for Applied Materials 1/4 Size Single Junction Version 10: Voc=96.2 V, beta_Voc=-0.33%/C, Isc=1.7 A, STC=116.0 W, Area=1.43 m2.
Result: 5 panels max on 600 V (536.5 V); 69 panels for 8 kW (1,062 sq ft).
What Are the Published CEC Specifications for Applied Materials 1/4 Size Single Junction Version 10?
Laboratory test ratings recorded for Applied Materials 1/4 Size Single Junction Version 10 (Thin Film) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 116.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 107.9 W (93.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 96.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 1.7 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 77.8 V / 1.47 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.33 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 8.11% (1.43 m2) | Array roof footprint density |
| Cell Count & Technology | 106 cells (Thin Film) | Monofacial backsheet |
How Many Applied Materials 1/4 Size Single Junction Version 10 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (1,062 sq ft at 8 kW), and estimated Year-1 electric bill offset for Applied Materials 1/4 Size Single Junction Version 10.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 52 | 6.03 kW | 800 sq ft | $1,509 | $2,552 |
| 8 kW Class | 69 | 8.0 kW | 1,062 sq ft | $2,002 | $3,386 |
| 10 kW Class | 87 | 10.09 kW | 1,339 sq ft | $2,525 | $4,270 |
How Many Applied Materials 1/4 Size Single Junction Version 10 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Applied Materials 1/4 Size Single Junction Version 10 (beta_Voc -0.33%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 110.49 V | 5 panels | 552.4 V | 9 panels |
| -10 C (14 F) | 107.31 V | 5 panels | 536.5 V | 9 panels |
| 0 C (32 F) | 104.14 V | 5 panels | 520.7 V | 9 panels |
| 25 C (77 F STC) | 96.2 V | 6 panels | 577.2 V | 10 panels |
Which Cross-Brand Solar Modules Compare Closest to Applied Materials 1/4 Size Single Junction Version 10?
Closest cross-brand CEC competitors to Applied Materials 1/4 Size Single Junction Version 10 matched near 116.0 W STC and 96.2 V Voc, led by Du Pont Apollo DA105-A2.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Du Pont Apollo DA105-A2 Du Pont Apollo |
105.0 W | -11.0 W | 100.0 V | 6.82% | 91.0% |
| T-Solar Global TS102 T-Solar Global |
102.5 W | -13.5 W | 93.0 V | 7.19% | 93.0% |
| Du Pont Apollo DA102-A6 Du Pont Apollo |
102.0 W | -14.0 W | 100.0 V | 6.62% | 94.2% |
| T-Solar Global TS97 T-Solar Global |
97.5 W | -18.5 W | 93.0 V | 6.84% | 92.9% |
What Are the Design Limits and Best-Fit Uses for Applied Materials 1/4 Size Single Junction Version 10?
Evaluate Applied Materials 1/4 Size Single Junction Version 10 (116.0 W STC, 96.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Applied Materials 1/4 Size Single Junction Version 10 reaches 110.49 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
- Footprint constraint: 69 panels for an 8 kW build require 1,062 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 69 panels (1,062 sq ft).
- 2026 tax credit baseline: cash residential installs of Applied Materials 1/4 Size Single Junction Version 10 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Applied Materials 1/4 Size Single Junction Version 10 8 kW Residential Fit
Needs 69 modules (1,062 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 5 panels (-10 C) or 5 panels (-20 C), or compare Du Pont Apollo DA105-A2.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 107.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Applied Materials 1/4 Size Single Junction Version 10 by Applied Materials grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Applied Materials 1/4 Size Single Junction Version 10?
Multiplying Applied Materials 1/4 Size Single Junction Version 10's 1.7 A short-circuit current by 1.56 equals 2.65 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Applied Materials 1/4 Size Single Junction Version 10 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 107.31 V cold Voc at 14 F and handles 1.7 A Isc; string inverters cap Applied Materials 1/4 Size Single Junction Version 10 at 5 panels on 600 V.
Is Applied Materials 1/4 Size Single Junction Version 10 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Applied Materials 1/4 Size Single Junction Version 10 rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)