Skip to main content
WireAndSun
Calculators
CEC PV Module

Applied Materials 1/4 Size Single Junction Version 10 — CEC Solar Module Specifications

Manufacturer: Applied Materials Registry: CEC Verified Engineering Specification

Applied Materials 1/4 Size Single Junction Version 10 is a 116.0 W STC (107.9 W PTC) Thin Film solar module ranking #21,509 of 21,677 CEC listings (below all-CEC median; higher than 0.8% of peers). It delivers 8.11% efficiency, 96.2 V Voc at 25 C, and 107.31 V cold Voc at -10 C (5 panels max per 600 V string).

STC Wattage
116.0 W
PTC Wattage
107.9 W
Voc @ 25C
96.2 V
Efficiency
8.11%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Applied Materials 1/4 Size Single Junction Version 10 Compare Against Peer CEC Listings?

Engineering position of Applied Materials 1/4 Size Single Junction Version 10 (116.0 W STC) vs. Du Pont Apollo DA105-A2 across 106 CEC Thin Film solar modules.

Built with 106 Thin Film cells, Applied Materials 1/4 Size Single Junction Version 10 pairs strong 93.0% PTC-to-STC heat retention (#9,879 of 21,677) with 96.2 V nominal Voc. An 8 kW residential build (8,004 W DC, 7,445 W PTC) saves ~$2,002/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Du Pont Apollo DA105-A2 offers a 105.0 W alternative.

Where Does Applied Materials 1/4 Size Single Junction Version 10 Fall Across Listed CEC Models?

Plots Applied Materials 1/4 Size Single Junction Version 10 at 116.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Applied Materials 1/4 Size Single Junction Version 10 (116.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCApplied Materials : 116.0 W

What Dataset Percentiles Define Applied Materials 1/4 Size Single Junction Version 10?

Benchmarks Applied Materials 1/4 Size Single Junction Version 10 on STC wattage, thermal PTC/STC retention, and 8.11 aperture conversion efficiency against CEC peers.

Applied Materials 1/4 Size Single Junction Version 10 Engineering BenchmarksPercentile comparison of Applied Materials 1/4 Size Single Junction Version 10 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage116.0 WPTC/STC Retention93.0%Module Efficiency8.11%

What Do the Dataset Ranks Show for Applied Materials 1/4 Size Single Junction Version 10?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Applied Materials 1/4 Size Single Junction Version 10 by Applied Materials.

Rank #21,509 / 21,677

116.0 W STC · Higher Than 0.8%

116.0 W STC (-269.0 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,651

8.11% Aperture Efficiency

Power density 81.1 W/m2 (11.80 percentage points below 19.91% CEC median). PTC/STC ratio: 93.0% (rank #9,879).

NEC 690.7 Limit

5 Panels Max @ -10 C (600 V)

Cold Voc reaches 107.31 V at -10 C (536.5 V string) and 110.49 V at -20 C (5 max).

8 kW Reference Array

69 Panels = 8,004 W STC

Occupies 98.7 m2 (1,062 sq ft) producing 7,445 W PTC; NEC 690.8 OCPD floor is 2.65 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 96.2 * (1 + (-0.33/100) * (-10 - 25)) = 107.31 V | OCPD = 1.56 * 1.7 = 2.65 A

Inputs from CEC Modules.csv for Applied Materials 1/4 Size Single Junction Version 10: Voc=96.2 V, beta_Voc=-0.33%/C, Isc=1.7 A, STC=116.0 W, Area=1.43 m2.

Result: 5 panels max on 600 V (536.5 V); 69 panels for 8 kW (1,062 sq ft).

What Are the Published CEC Specifications for Applied Materials 1/4 Size Single Junction Version 10?

Laboratory test ratings recorded for Applied Materials 1/4 Size Single Junction Version 10 (Thin Film) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Applied Materials 1/4 Size Single Junction Version 10.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 116.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 107.9 W (93.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 96.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 1.7 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 77.8 V / 1.47 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.33 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 8.11% (1.43 m2) Array roof footprint density
Cell Count & Technology 106 cells (Thin Film) Monofacial backsheet

How Many Applied Materials 1/4 Size Single Junction Version 10 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (1,062 sq ft at 8 kW), and estimated Year-1 electric bill offset for Applied Materials 1/4 Size Single Junction Version 10.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 52 6.03 kW 800 sq ft $1,509 $2,552
8 kW Class 69 8.0 kW 1,062 sq ft $2,002 $3,386
10 kW Class 87 10.09 kW 1,339 sq ft $2,525 $4,270

How Many Applied Materials 1/4 Size Single Junction Version 10 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Applied Materials 1/4 Size Single Junction Version 10 (beta_Voc -0.33%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=96.2V and beta_Voc=-0.33%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 110.49 V 5 panels 552.4 V 9 panels
-10 C (14 F) 107.31 V 5 panels 536.5 V 9 panels
0 C (32 F) 104.14 V 5 panels 520.7 V 9 panels
25 C (77 F STC) 96.2 V 6 panels 577.2 V 10 panels

Which Cross-Brand Solar Modules Compare Closest to Applied Materials 1/4 Size Single Junction Version 10?

Closest cross-brand CEC competitors to Applied Materials 1/4 Size Single Junction Version 10 matched near 116.0 W STC and 96.2 V Voc, led by Du Pont Apollo DA105-A2.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Du Pont Apollo DA105-A2
Du Pont Apollo
105.0 W -11.0 W 100.0 V 6.82% 91.0%
T-Solar Global TS102
T-Solar Global
102.5 W -13.5 W 93.0 V 7.19% 93.0%
Du Pont Apollo DA102-A6
Du Pont Apollo
102.0 W -14.0 W 100.0 V 6.62% 94.2%
T-Solar Global TS97
T-Solar Global
97.5 W -18.5 W 93.0 V 6.84% 92.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Applied Materials 1/4 Size Single Junction Version 10?

Evaluate Applied Materials 1/4 Size Single Junction Version 10 (116.0 W STC, 96.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Applied Materials 1/4 Size Single Junction Version 10 reaches 110.49 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 69 panels for an 8 kW build require 1,062 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 69 panels (1,062 sq ft).
  • 2026 tax credit baseline: cash residential installs of Applied Materials 1/4 Size Single Junction Version 10 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Applied Materials 1/4 Size Single Junction Version 10 8 kW Residential Fit

Needs 69 modules (1,062 sq ft) with a 15 A string OCPD, offsetting ~$2,002/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 5 panels (-10 C) or 5 panels (-20 C), or compare Du Pont Apollo DA105-A2.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 107.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Applied Materials 1/4 Size Single Junction Version 10 by Applied Materials grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Applied Materials 1/4 Size Single Junction Version 10?

Multiplying Applied Materials 1/4 Size Single Junction Version 10's 1.7 A short-circuit current by 1.56 equals 2.65 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Applied Materials 1/4 Size Single Junction Version 10 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 107.31 V cold Voc at 14 F and handles 1.7 A Isc; string inverters cap Applied Materials 1/4 Size Single Junction Version 10 at 5 panels on 600 V.

Is Applied Materials 1/4 Size Single Junction Version 10 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Applied Materials 1/4 Size Single Junction Version 10 rely on utility bill offset (~$2,002/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.